DMA Direct memory access
FRU Field-replaceable unit
PAA P = Adapter port number
AA = SSA address
(see also 'Finding the Device When No Service Aids Are Available')
PCI Peripheral Component Interconnect
POST Power-On Self-Test
Using the SRN Table
You should have been sent here from either
diagnostics or a START MAP. Do not start problem determination from the SRN table;
always go to the START MAP for the unit in which the device is installed.
SRN | FRU List | Problem |
---|---|---|
20PAA | Device (45%) ('Exchanging Disk Drives'). SSA adapter card (45%) External SSA cables (6%) Internal SSA connections (4%) (unit Hardware Maint. Manual) |
An open SSA link has been detected. Run the Disk service aid to isolate the failure (see 'Using the SSA Service Aids and Other Service Tools'). If the SSA service aids are not available go to the service information for the unit in which the device is installed. |
21PAA to 29PAA |
Device (45%) ('Exchanging Disk Drives') SSA Adapter card (45%) External SSA cables (6%) Internal SSA connections (4%) (unit Hardware Maint. Manual) |
An SSA 'Threshold exceeded' link error has been detected. Go to MAP 2010 'START' |
2A002 | Device (50%) ('Exchanging Disk Drives') SSA adapter card (50%) |
Async code 02 has been received. Probably a software error has occurred. Go to 'Software and Microcode Errors' before exchanging any FRUs. |
2A003 | Device (50%) ('Exchanging Disk Drives') SSA adapter card (50%) |
Async code 03 has been received. Probably a software error has occurred. Go to 'Software and Microcode Errors' before exchanging any FRUs. |
2A004 | Device (50%) ('Exchanging Disk Drives') SSA adapter card (50%) |
Async code 04 has been received. Probably a software error has occurred. Go to 'Software and Microcode Errors' before exchanging any FRUs. |
2FFFF | None | An async code that is not valid has been received. Go to 'Software and Microcode Errors'. |
40000 | SSA adapter card (100%) | The SSA adapter card has failed. Exchange the FRU for a new FRU. |
40004 | 4 MB DRAM module 0 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 4MB DRAM in adapter card module 0 has failed. Exchange the FRU for a new FRU. |
40008 | 8 MB DRAM module 0 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 8MB DRAM in adapter card module 0 has failed. Exchange the FRU for a new FRU. |
40016 | 16 MB DRAM module 0 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 16MB DRAM in adapter card module 0 has failed. Exchange the FRU for a new FRU. |
40032 | 32 MB DRAM module 0 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 32MB DRAM in adapter card module 0 has failed. Exchange the FRU for a new FRU. |
40064 | 64 MB DRAM module 0 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 64MB DRAM in adapter card module 0 has failed. Exchange the FRU for a new FRU. |
40128 | 128 MB DRAM module 0 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 128MB DRAM in adapter card module 0 has failed. Exchange the FRU for a new FRU. |
41004 | 4 MB DRAM module 1 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 4MB DRAM in adapter card module 1 has failed. Exchange the FRU for a new FRU. |
41008 | 8 MB DRAM module 1 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 8MB DRAM in adapter card module 1 has failed. Exchange the FRU for a new FRU. |
41016 | 16 MB DRAM module 1 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 16MB DRAM in adapter card module 1 has failed. Exchange the FRU for a new FRU. |
41032 | 32 MB DRAM module 1 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 32MB DRAM in adapter card module 1 has failed. Exchange the FRU for a new FRU. |
41064 | 64 MB DRAM module 1 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 64MB DRAM in adapter card module 1 has failed. Exchange the FRU for a new FRU. |
41128 | 128 MB DRAM module 1 (100%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
A 128MB DRAM in adapter card module 1 has failed. Exchange the FRU for a new FRU. |
42000 | SSA adapter card (50%) DRAM modules (50%) 'Exchanging DRAMs on the SSA RAID cluster Adapter' |
The SSA adapter has detected that both DRAM modules are failing. 1. Check whether both DRAM modules are correctly installed on the adapter card. Make any necessary corrections. 2. It this problem has occurred immediately after an upgrade to the adapter card, check whether the correvt type of DRAM modules have been installed. Make any necessary corrections. 3. If the problem remains, eachange the adapter card FRU for a new one. Do not exchange any DRAM modules yet. 4. Install the DRAM modules from the original adapter card onto the new adapter card, then install the new adapter card. 5. If the problem remains, exchange the DRAM modules for new modules. 6. Install the new DRAM modules onto the original adapter card. Reinstall the original adapter card. |
42500 | Write cache card on the SSA adapter card (100%) |
The SSA adapter has detected a failure in the write cache. Exchange the FRU for a new FRU. |
43PAA | Device (90%) ('Exchanging Disk Drives') SSA adapter card (10%) |
An SSA device on the link is preventing the completion of the loop configuration. Go to MAP 2010 'START'. |
44PAA | Device (100%) ('Exchanging Disk Drives') |
An SSA device has a 'Failed' status. If the SSA service aids are available, run the Disk service aid (see 'Using the SSA Service Aids and Other Service Tools' to find the failing device, If no device is listed as Rejected, use the PAA part of the SRN to determine which device is failing. Before you exchange the failing device, run nonconcurrent diagnostics to that device to determine the cause of the problem. If the SSA service aids are not available, note the value of PAA in this SRN, and go to 'Finding the Physical Location of a Device'. Exchange the failing FRU for a new FRU. |
45PAA | Device (40%) ('Exchanging Disk Drives') SSA Adapter card (40%) SSA cables, or other SSA connections in the device enclosure (20%). (unit Hardware Maint. Manual). |
The SSA adapter has detected an open SSA loop. If the SSA service aids are available, run the Disk service aid (see 'Using the SSA Service Aids and Other Service Tools') to determine which part of the loop is failing. If the SSA service aids are not available, note the value of PAA in this SRN, and go to 'Finding the Physical Location of a Device'. |
47000 | None | An attempt has been made to store in the SSA adapter the details of more than 32 arrays. Go to MAP 2010 'START'. |
47500 | None | Part of the array data might have been lost. Go to MAP 2010 'START'. |
48000 | None | The SSA adapter has detected a link configuration that is not valid. See 'SSA Loop Configurations that Are Not valid' |
49000 | None | An array is in the Degraded State because a disk drive is not available to the array, and a write command has been sent to that array. A disk drive might not be available for one of the following reasons: ° The disk drive has failed. ° The disk drive has been removed from the subsystem. ° An SSA link has failed. ° A power failure has occurred. Go to MAP 2010 'START'. |
4910O | None | An array is in the Exposed state because a disk drive is not available to the array. A disk drive can become not available for several reasons: ° The disk drive has failed. ° The disk drive has been removed from the subsystem. ° An SSA link has failed. ° A power failure has occurred. Go to MAP 2010 'START' |
49500 | None | No hot spare disk drives are available for an array that is configured for hot spare disk drives. Go to MAP 2010 'START'. |
4C000 | None | A configuration that is not valid has been detected. Some disk drives do not have failover protection. Go to 'SSA Loop Configurations that Are Not valid' |
4C200 | None | A configuration that is not valid has been detected. Corresponding SSA adapters are not wired together. Go to 'SSA Loop Configurations that Are Not valid' |
4C400 | None | A configuration that is not valid has been detected. One system must be configured as A and the other as B. Go to 'SSA Loop Configurations that Are Not valid'. |
4C600 | None | Failover has occurred. This SSA adapter is now controlling the arrays. Run the Disk service aid, and check the SSA configuration for correct connections and for correct SSA adapter operation. |
4C800 | None | Only one member of a RAID 1 array is present, and its owning adapter serial number does not match that of this adapter. Do one of the following actions: ° Install the other member of the array onto this SSA adapter. ° Remove the array member from this SSA adapter. ° If you want to continue to use the one member on this SSA loop, go to 'Modifying Attributes of Resources', and set the Split Resolution field to the member number of the array member that you want to use. |
4E000 | Device (100%) 'Exchanging Disk Drives' |
Data Scrubbing has reconstructed a data block and reassigned the affected blocks. If this SRN occurs three times in 24 hours, exchange the FRU for a new FRU. |
4F000 | None | The SSA adapter has detected duplicate disk attachment numbers. The disk drive that has the duplicate attachment number has been designated as a new resource. Reattach the disk drive in the required position (See 'Attaching a Resource to the System'). |
4F100 | None | Both members of a RAID 1 array are indicating that they have been updated while the other member was not available. The array name is reported. (A corresponding SRN 4F101 is also logged.) If you want to continue to use this array, you must specify one of the members as the member that contains good data, and update the data of the other member to match it. To do this, go to 'Modifing Attributes of Resources', and set the Split Resolution field to the member number of the array member that you want to use. |
4F101 | None | Both members of a RAID 1 array are indicating that they have been updated while the other member was not available. The UID/array name of the member that was not available is reported. (A corresponding SRN 4F100 is also logged.) If you want to continue to use this array, you must specify one of the members as the member that contains good data, and update the data of the other member to match it. To do this, go to 'Modifying Attributes of Resources', and set the Split Resolution field to the member number of the array member that you want to use. |
4F200 | None | A member of a RAID 1 array has been detected. The array name is reported. Delete this SRN. |
4F201 | None | A member of a RAID 1 array has been rejected. The member UID is reported. Delete this SRN. |
50000 | SSA adapter card (100%) | The SSA adapter failed to respond to the device driver. Exchange the FRU for a new FRU. |
50001 | SSA adapter card (100%) | A data parity error has occurred. Exchange the FRU for a new FRU. |
50002 | SSA adapter card (100%) | An SSA adapter DMA error has occurred. Exchange the FRU for a new FRU. |
50004 | SSA adapter card (100%) | An adapter error has been detected. Exchange the FRU for a new FRU. |
50005 | SSA adapter card (100%) | A software error has occurred. Go to 'Software and Microcode Errors', before exchanging the FRU. |
50006 | SSA adapter card (100%) | An adapter error has been detected. Exchange the FRU for a new FRU. |
50007 | SSA adapter card (100%) | An adapter error has been detected. Exchange the FRU for a new FRU. |
50008 | SSA adapter card (100%) | Unable to read or write the PCI registers. Exchange the FRU with a new FRU. |
50010 | SSA adapter card (100%) | An SSA adapter or device drive protocol error has occurred. Go to 'Software and Microcode Errors', before exchanging the FRU. |
50012 | SSA adapter card (100%) | The SSA adapter microcode bus hung. Run nonconcurrent diagnostics to the SSA adapter. If the diagnostics fail. exchange the FRU for a new FRU. If the diagnostics do not fail, go to 'Software and Microcode Errors', before exchanging the FRU. |
D4000 | SSA adapter card (100%) | The diagnostics cannot configure the SSA adapter. Exchange the FRU for a new FRU. |
D4100 | SSA adapter card (100%) | The diagnostics cannot open the SSA adapter. Exchange the FRU for a new FRU. |
D4300 | SSA adapter card (100%) | The diagnostics have detected an SSA adapter POST failure. Exchange the FRU for a new FRU. |
DFFFF | SSA adapter card (100%) | A command or parameter that has been sent or received is not valid. This problem is caused either by the SSA adapter, or by an error in the microcode. Go to 'Software and Microcode Errors', before exchanging the FRU. |
:p
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.