|001|
+---+
Before you arrived at this MAP, you might have exchanged
one or more FRUs for new FRUs. Some of those FRUs
(for example, disk drives) have Power lights.
- Check whether all those Power lights are on.
DO ALL THE FRUS YOU HAVE EXCHANGED HAVE THEIR POWER LIGHTS ON
(WHERE APPLICABLE)?
+---+
Yes No-+002|- Exchange, for a new one, the FRU whose Power light is oft.
| +---+ Go to Step 004.
+-+-+
|003|
+---+
Go to Step 004.
------------------------------------------------------------------------
+---+
|004|
+---+
ARE ALL CHECK LIGHTS OFF?
+---+
Yes No-+005|Go to the START MAP for the unit in which the
+---+device with its Check light on is installed.
- Run concurrent diagnostics to the device that reported the problem.
Notes:
1. Do not run nonconcurrent diagnostics, otherwise, errors are logged on
other systems that share the same loop.
2. If you have just exchanged a disk drive or an SSA RAID Cluster Adapter,
you must use the configurator to restore the device to the system.
- If the original problem was not reported by a device, run diagnostics
to each SSA RAID Cluster Adapter in the system unit.
- Do the problem tix procedure (see 'Problem Fix Procedure').
Note: If you do not do the problem fix procedure, the
diagnostics might create an SRN for a problem that you have
already solved.
If you have a RAID array, and the problem remains, go to
RAID Checkout at MAP 2324 step 032.
------------------------------------------------------------------------
Please see the LEGAL - Trademark notice.