Record number: H037848
Device: D/T8642
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key: 006
Date created: O98/05/27
Date last altered: A98/06/02
Owning B.U.: USA
Abstract: PC SERVER 720 HEALTH CHECKLIST
TEXT:
The Purpose of this TIP is for use as a "Health Check" to identify ECA's and RETAIN tips that provide information and
fixes to Server stability issues pertaining to models of the PC Server 720 Type 8642.
Each of the existing ECA's listed below have a Physical and / or logical check to determine
if the ECA is necessary.
Use the Matrix Below to determine which ECA(s) apply:
ECA ECA ECA ECA ECA ECA ECA
001 002 003 005 006 012 016
__________________________________________
| |
720 | x x x x x |
|..........................................|
720 RAID | x x x x x x x |
|__________________________________________|
The following ECAs are available: RETAIN
-------
ECA001 320/720 SCSI Cable replacement H132199
ECA002 8642 100Mhz Processor for NetWare SMP H132301
ECA003 Prevent Multiple DDD SCSI Drives in Server H133326
ECA005 8642 Processor and Memory card replacement H133731
ECA006 Server PCI RAID Adapter replacement H133523
ECA007 PC Server 320 Power Supply replacement (API) H135078
ECA012 1.12GB, 2.25GB Hard Drive replacement H161379
ECA016 Firmware Upgrade for some 4.5/9.1GB SCSI Drives H162303
The following RETAIN tips resolve issues not covered by the
existing ECA's, and each have a "Isolation Aids" section to determine if the tip applies to the Server's
specific hardware / software configuration:
H13697, RAID Array Fixed Disk Drive Replacement Process
H121366, Electronic Component Failures in IBM PC Products
H122801, Bowed Backplane may cause Hardfile Problems
H132071, 4x SCSI CDROM Read errors on Server-720
H133777, Server Backplane Address Jumper configuration
H134082, RAID Array:Data Scrubbing,prevent RAID Rebuild Failures
H134111, Prevent false DDD errors on Server hard drives
H134499, Bridge Card LED remains Off with BIOS 09
H134640, Server 720 (133Mhz or 166Mhz) Traps or Hangs
H134877, Server 720 runs slow after running Diagnostics
H135499, PCI RAID Server Traps or Hangs intermittently
H135767, Server 720 Hangs with ServeRAID and/or PCI Token Ring
H136094, PC Server runs slow while mirroring with NetWare
H136237, PC Server 720 (8642) Processor Card Support
H136613, Server RAID drives DDD with ArcServe Tape Support
H137828, PC Server 720 Hangs with Windows NT Server
H161857, DDD drives may not rebuild automatically to HSP
To apply the Health Check to a PC Server 720 Type 8642, see
ECA008, RETAIN Record #H137086