Abstract: SERVER RAID DRIVES DDD WITH ARCSERVE TAPE BACKUP
SYMPTOM:
One or more drives become DDD while the ARCserve program is
loading OR during a tape backup with ARCserve.
The following message may also appear after exiting NetWare:
Bad or missing Command Interpreter
PROBLEM ISOLATION AIDS:
- The system is a PC Server with an IBM RAID adapter
- The Operating System is NetWare 3.x or 4.x
- The tape backup application is ARCserve version 6.0
FIX:
Edit the file TAPESRV.CFG (usually located on the SYS volume in
the ARCSERVE.6 NLM subdirectory).
Add the following two(2) statements to the bottom of the file:
[Config]
NOLUN=ENABLE
Note:
Before downing a NetWare Server with ARCserve version 6.0,
always issue the command "ASTOP6" from the NetWare console.
This action performs a graceful shutdown of the ARCserve
application.
ARCserve is a trademark of Cheyenne Software Inc.
NetWare is a trademark of Novell, Inc.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.