Record number: H136094
Device: D/T8640
Model: M
Hit count: UHC00141
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O97/01/14
Date last altered: A98/06/10
Owning B.U.: USA
Abstract: PC SERVER runs SLOW while MIRRORING with NetWare
SYMPTOM:
While Mirroring or Duplexing with NetWare, the Server runs slowly. Performance is degraded.
PROBLEM ISOLATION AIDS:
The system is a PC Server with one or more of the following Adaptec SCSI Adapters / Controller installed:
FIX:
Edit the STARTUP.NCF so the loading of the Adaptec device drivers are as follows:
For Duplexing:
load aic7870.dsk slot=xx read_after_write=1 (primary drive)
load aic7870.dsk slot=xx read_after_write=0 (mirrored drive)
For Mirroring:
load aic7870.dsk slot=xx read_after_write=0
By default (no parameters), read after write verification is ENABLED for the aic7870.dsk device driver.
By using the "read_after_write=0" parameter, read after write
verification is DISABLED and system performance is improved.
Read after write verification will appear "DISABLED" for the
mirrored drive on the NetWare Monitor (Disk Information) screen
when "read_after_write=0" is used as the parameter.
Adaptec is a trademark of Adaptec, Inc.
NetWare is a trademark of Novell, Inc.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.