Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Processor Board Assembly Removal (Netfinity 7000-M10 - Type 8680)



Processor Board Assembly Removal

Before you begin: Read 'Safety Information'.
 

To remove the processor board, do the following:
  1.  Power-off the system.
  2.  Disconnect all power to the system.
  3.  Remove the top cover, see 'Removing the Top Cover'.
  4.  Remove the front bezel, see 'Removing the Front Bezel'.
  5.  Remove the following items, see 'Microprocessor Installation'.

    1.  Processor Retention Bracket -1-
    2.  Processor(s) -2-
    3.  Processor Terminator Card -3-
    4.  Memory Card -4-
    5.  Memory Terminator Card -5-
    6.  VRM Retention Bracket -6-

  6.  Disconnect the processor board cables.
  7.  Remove the shuttle assembly, see 'Shuttle Assembly Removal'.
  8.  Turn the three quarter-turn fasteners -7- and remove the processor board assembly.


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.