 |
IBM-AUSTRIA - PC-HW-Support 30 Aug 1999 |
Processor Board Assembly Removal (Netfinity 7000-M10 - Type 8680)
Processor Board Assembly Removal
Before you begin: Read 'Safety Information'.
To remove the processor board, do the following:
- Power-off the system.
- Disconnect all power to the system.
- Remove the top cover, see 'Removing the Top Cover'.
- Remove the front bezel, see 'Removing the Front Bezel'.
- Remove the following items, see 'Microprocessor Installation'.
- Processor Retention Bracket -1-
- Processor(s) -2-
- Processor Terminator Card -3-
- Memory Card -4-
- Memory Terminator Card -5-
- VRM Retention Bracket -6-
- Disconnect the processor board cables.
- Remove the shuttle assembly, see 'Shuttle Assembly Removal'.
- Turn the three quarter-turn fasteners -7- and remove the processor board assembly.
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a
for any BUG on this page found - Thank you.