The System Security choice appears only on the full Configuration/Setup Utility main menu.
After you set a power-on or administrator password, you must enter the password when you turn on
the server. (The passwords do not appear on the screen as you type them.)
Type of Password | Results |
---|---|
No password set | ° No password required to start the system |
° You can access all choices on the | |
Configuration/Setup Utility main menu. | |
Power-on password only | ° You must enter the password to complete |
the system startup. | |
° You can access all choices on the | |
Configuration/Setup Utility main menu. | |
Administrator | ° You must enter the password to complete |
password only | the system startup. |
° The Administrator password provides | |
access to all choices on the | |
Configuration/Setup Utility main menu. | |
Administrator and | You can enter either password to complete the |
power-on password | system startup. |
° The administrator password provides | |
access to all choices on the | |
Configuration/Setup Utility main menu. You | |
can set, change, or delete both the | |
administrator and power-on passwords, and | |
allow a power-on password to be changed | |
by the user. | |
° The power-on password provides access to | |
a limited set of choices on the | |
Configuration/Setup Utility main menu. This | |
limited access might include changing or | |
deleting the power-on password. | |
° If you forget the power-on password, and | |
the administrator password has been set, | |
use the administrator password at the | |
power-on password prompt, then, start the | |
Configuration/Setup Utility program and | |
change the power-on password. |
Using the Power-On Password Menu: When a power-on password is set,
you must enter a password each time that you start the system.
When a power-on password is set, POST does not complete until you enter the password.
If you forget the power-on password, you can regain access to the server through one of the
following methods:
To set a power-on password:
You can use any combination of up to seven characters (A-Z, a-z, and 0-9) for the power-on password.
Keep a record of the password in a secure place.
Note: A message appears if the two passwords do not match. If this happens, press Esc to cancel the request and return to the System Security menu.
To delete a power-on password:
The Power-on Password menu appears.
To allow the system to start in unattended-start mode when a power-on password is set:
Using the Administrator Password Menu: The administrator password
(sometimes called a supervisor-level password) controls access to some features of the server,
including the Configuration/Setup Utility program.
- Attention - If an administrator password is set
and then forgotten, it cannot be overridden or removed.
You must replace the I/O board.
To set an administrator password:
The Administrator Password menu appears.
A password can contain any combination of up to seven alphanumeric characters (A-Z, a-z, and 0-9).
Keep a record of the password in a secure place.
Note: A message appears if the two passwords do not match. If this happens, press Esc to cancel the request and return to the System Security menu.
To delete an administrator password:
To enable a user to change the power-on password:
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.