PAA
|||
|++----- SSA address
+------- Adapter port number
SRN | Description | Action |
---|---|---|
2OPAA | An open SSA link has been detected | Call for service |
21PAA to 29PAA |
An SSA 'Threshold exceeded' link error has been detected. |
Call for service |
2A002 | Async code 02 has been received Probably, a software error has occurred. |
Call for service |
2A003 | Async code 03 has been received Probably, a software error has occurred. |
Call for service |
2A004 | Async code 04 has been received Probably, a software error has occurred. |
Call for service |
2FFFF | Async code that is not valid has been received error has occurred. |
Call for service |
40000 | The SSA adapter card has failed | Exchange the adapter for a new one or call for service. |
40004 | A 4 MB DRAM module in adapter card slot 0 has failed. |
Call for service or exchange the DRAM for a new one. |
40008 | A 8 MB DRAM module in adapter card slot 0 has failed. |
Call for service or exchange the DRAM for a new one. |
40016 | A 16 MB DRAM module in adapter card slot 0 has failed. |
Call for service or exchange the DRAM for a new one. |
40032 | A 32 MB DRAM module in adapter card slot 0 has failed. |
Call for service or exchange the DRAM for a new one. |
40064 | A 64 MB DRAM module in adapter card slot 0 has failed. |
Call for service or exchange the DRAM for a new one. |
40128 | A 128 MB DRAM module in adapter card slot 0 has failed. |
Call for service or exchange the DRAM for a new one. |
41004 | A 4 MB DRAM module in adapter card slot 1 has failed. |
Call for service or exchange the DRAM for a new one. |
41008 | A 8 MB DRAM module in adapter card slot 1 has failed. |
Call for service or exchange the DRAM for a new one. |
41016 | A 16 MB DRAM module in adapter card slot 1 has failed. |
Call for service or exchange the DRAM for a new one. |
41032 | A 32 MB DRAM module in adapter card slot 1 has failed. |
Call for service or exchange the DRAM for a new one. |
41064 | A 64 MB DRAM module in adapter card slot 1 has failed. |
Call for service or exchange the DRAM for a new one. |
41128 | A 128 MB DRAM module in adapter card slot 1 has failed. |
Call for service or exchange the DRAM for a new one. |
42000 | The SSA adapter has detected that both DRAM modules are failing. |
Call for service or: 1. Check whether both DRAM modules are correctly installed on the adapter card. Make any necessary corrections. 2. If this problem has occurred immediately after an upgrade to the adapter card, check whether the correct type of DRAM modules have been installed. Make any necessary corrections. 3. If the problem remains, exchange the adapter card for a new one. Do not exchange any DRAM modules yet. 4. Install the DRAM modules from the original adapter card onto the new adapter card, then install the new adapter card. 5. If the problem remains, exchange the DRAM modules for new modules. 6. Install the new DRAM modules onto the original adapter card. Reinstall the original adapter card. |
42500 | Write cache card on the SSA adapter card (100%) |
The SSA adapter has detected a failure in the write cache. Exchange the FRU for a new FRU. |
43PAA | An SSA device is preventing the completion of the loop configuration. |
Call for service |
45PAA | The SSA adapter has detected an open SSA loop. |
Check that all the SSA cables are connected correctly. If the problem remains, call for service. |
47000 | An attempt has been made to store in the SSA adapter the details of more than 32 RAID arrays. |
Call for service |
47500 | Part of the RAID array data might have been lost. |
Call for service |
48000 | The SSA adapter has detected a loop configuration that is not valid. |
Go to 'SSA Loop Configurations that Are Not valid' or call for service |
49000 | A RAID array is in the Degraded state because a disk drive is not available to the array, and a write command has been sent to that array. A disk drive might not be available for one of the following reasons: ° The disk drive has failed. ° The disk drive has been removed from the subsystem. ° An SSA link has failed. ° A power failure has occurred. |
Call for service |
49100 | A RAID array is in the Exposed state because a disk drive is not available to the array. A disk drive can become not available for several reasons: ° The disk drive has failed. ° The disk drive has been removed from the subsystem. ° An SSA link has failed. ° A power failure has occurred. |
Call for service |
49500 | No hot-spare disk drives are available for a RAID array that is configured for hot-spare disk drives. |
Call for service |
4C000 | Unsupported configuration because there are disks that do not have failover protection. |
Go to 'SSA Loop Configurations that Are Not valid' or call for service |
4C200 | Corresponding adapters are not wired together |
Go to 'SSA Loop Configurations that Are Not Valid' or call for service |
4C400 | One host must be configured as A and the other as B. |
Go to 'SSA Loop Configurations that Are Not valid' or call for service |
4C600 | Failover has occurred: this adapter is now controlling the arrays. |
Run the Disk Service Aids, and check the SSA configuration for correct connections and for correct SSA adapter operation. (See 'Viewing the Physical Configuration') |
4C800 | One component of RAID-1 present and owning adapter serial number does not match that of this adapter. |
Do one of the following: ° Install the other member of the array onto this SSA adapter ° Remove the array member from this adapter ° If you want to continue to use the one member on this SSA loop, go to 'Changing Array Attributes' and set the Split Resolution field to the member number of the array member that you want to use. |
4E000 | Data scrubbing has reconstructed a data block and reassigned it. |
If this SRN occurs three or more times in 24 hours, exchange the adapter for a new one or call for service. |
4F000 | The SSA adapter has detected duplicate disk attachment numbers. |
The disk drive that has the duplicate attachment number has been designated as a new resource. Reattach the disk drive in the required position, (see 'Attaching Resources'). |
4F100 | Both members of a RAID-1 array are indicating that they have been updated while the other member was not available. The array name is reported. (A corresponding SRN 4F101 is also logged.) |
If you want to continue to use this array, you must specify one of the members as the member that contains good data, and update the data on the other member to match it. To do this, go to 'Changing Array Attributes' and set the Split Resolution field to the member number of the array member that you want to use. |
4F101 | Both members of a RAID-1 array are indicating that they have been updated while the other member was not available. The UID/array name of the member that was not available is reported. (A corresponding 5RN 4F1 00 is also logged.) |
If you want to continue to use this array, you must specify one of the members as the member that contains good data, and update the data on the other member to match it. To do this, go to 'Changing Array Attributes' and set the Split Resolution field to the member number of the array member that you want to use. |
4F200 | A member of a RAID-1 array has been rejected (array name reported). |
None |
4F201 | A member of a RAID-1 array has been rejected (member serial number reported). |
None |
50000 | The SSA adapter failed to respond to the device driver. |
Exchange the adapter card for a new one or call for service |
50001 | A data parity error has occurred. | Exchange the adapter card for a new one or call for service |
50002 | An SSA adapter DMA error has occured. |
Exchange the adapter card for a new one or call for service |
50004 | An adapter error has been detected. |
Exchange the adapter card for a new one or call for service |
50005 | A software error has occurred. | Call for service |
50006 | An adapter error has been detected. |
Exchange the adapter card for a new one or call for service |
50007 | An adapter error has been detected. |
Exchange the adapter card for a new one or call for service |
50008 | Unable to read or write the PCI registers. |
Exchange the adapter card for a new one or call for service |
50010 | An SSA adapter or device drive protocol error has occurred. |
Call for service |
50012 | The SSA adapter microcode has hung. |
Call for service |
D4000 | The diagnostics cannot configure the SSA adapter. |
Exchange the adapter card for a new one or call for service |
D4100 | The diagnostics cannot open the SSA adapter. |
Exchange the adapter card for a new one or call for service |
D4300 | The diagnostics have detected an SSA adapter POST failure. |
Exchange the adapter card for a new one or call for service |
DFFFF | A command or parameter that has been sent or received is not valid. This problem is caused either by the SSA adapter, or by an error in the microcode. |
Call for service |