| | | Company | Headlines | Products | Downloads | Support | Comments | | Awards | Certificates | Employment | Search | Site Map | Home | Chapter set above: Mainboard HOT-419 (486, AT, OPTi)
Chapter set below: CPUs Systemclock CPU voltage VL-Bus settings Memory Cache size
Jumper | AMD 486 NV8T DX/DX2/DX4 (3.45V) ST 486 DX2 UMC U5S | Intel S-Series DX/DX2/DX4 marking "&E..." (3.3 or 5V) | Cyrix DX/DX2 Cyrix DX2V (3.3 or 4V) | 3 | 1-2 | 1-2 | 1-2 | 5 | 2-3 | 2-3 | 2-3 | 8 | 1-2 | 1-2 | 1-2 | 42 | open | 1-2 | 2-3 | 43 | DX2: 1-2 DX4: 2-3 | 1-2 | 2-3 | 44 | open | closed | open | 45 | open | closed | open | 46 | open | closed | open | 47 | open | open | closed | 48 | open | open | closed | 49 | 1-2 | 1-2 | 2-3 | 65 | . | Multiplier for DX4: 2x : closed 3x : open | . | 77 | 1-2 | 2-3 | 1-2 | Jumper | AMD 486 SV8B DX4 (3.45V) Intel P24D | Intel 486SX Non S-Series | Intel 486SX S-Series | 3 | 1-2 | open | open | 5 | 2-3 | 2-3 | 2-3 | 8 | 1-2 | 1-2 | 1-2 | 42 | open | open | 1-2 | 43 | 1-2 | 1-2 | 1-2 | 44 | open | open | closed | 45 | open | open | closed | 46 | open | open | closed | 47 | open | open | open | 48 | open | open | open | 49 | 1-2 | 1-2 | 1-2 | 59 | write back: closed write through: open | . | . | 77 | 1-2 | . | . | Systemclock | JP22 JP21 JP23 | 20 MHz | | 25 MHz | | 25 MHz (Intel DX4, only) | | 33 MHz | | 33 MHz (Intel DX4, only) | | 40 MHz | | 50 MHz | | 50 MHz (Intel DX4, only) | | CPU voltage | JP64 | JP73 | 3V | | | 3.3V for Intel 3V and Cyrix 3.3V | | | 3.45V für AMD 3V | | | 5V for all 5V CPUs | | No effect | VL-Bus Speed - JP34 | 33 MHz or more | | below 33 MHz | | High Speed Write- JP33 | No Waitstate | | 1 Waitstate | | CPU DRY# Signal Delay - JP55/69 | Setup 1 for fast VL-bus devices | | Setup 2 for slow VL-bus devices (recommended setting) | | Address hold time (ADS#) - JP36 | Normal operation | | Delay CPU ADS# signal | | HOT-419 provided two memory configuration modes, mode 1 and mode 2. Jumpers JP60, JP61, JP62, JP70, JP71, and JP72 are provided to configure the memory configuration between two memory configuration modes. In Mode 1 the mainboard supports 4 banks of socalled single density modules in sizes of 1, 4, 16 or 64MB. Mode 2 supports double density modules in sizes of 2, 8, or 32MB, too - but only 3 banks: the memory socket next to the ISA expansion slot must be left empty. The mainboard supports a total size of 2 to 128MB memory. Memory Mode 1 | Memory Mode 2 | | | Note: When memory configuration mode 1 is selected, HOT-419 mainboard supported two VESA master local bus slot, one on J20 (VL Bus slot 1), and the other one on J19 (VL-Bus slot 2) or J18 (VL-Bus slot 3). If memory configuration mode 2 is selected, HOT-419 mainboard only supported one VESA master local bus slot on J18 or J19, J20 is assigned to slave always. Cache size | Data SRAM Bank 0 U5...U8 | Data SRAM Bank 1 U9...U12 | Tag RAM U13 | JP 10, JP13 JP50, JP11 | 64 kB | 8k x 8 | 8k x 8 | 8k x 8 | | 128 kB | 32k x 8 | empty | 32k x 8 | | 256 kB | 32k x 8 | 32k x 8 | 32k x 8 | | 512 kB | 128k x 8 | empty | 32k x 8 | | © 1999 Shuttle Inc., Last modification: 01/13/2000 All other brand and product names within this page are the property of their respective owners. Shuttle assumes no responsibility for any errors or omissions. Nor does Shuttle make any commitment to update information, with or without prior notification. |