Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

ECA025: NETFINITY 5000 - HOT SWAP BACKPLANE REPLACEMENT



Subject: ECA025: NETFINITY 5000 - HOT SWAP BACKPLANE REPLACEMENT
Updated Netfinity server RETAIN ECA025: 

    Record number:       H165434
    Device:              D/T8659         Service code:      33
    ECA number:          ECA025          Parts source:      LOC
    EC number:           EC000000        Publish flag:      R
    Mandatory:           Y               Hit count:         UHC00053
    Automatic shipment:  N               Success count:     USC0000
    Availability date:   98/11           Publication code:  PC50
    Plant of control:    23              Date created:      O98/11/19
    Tip key:                             Date last altered: A99/04/15
                                         Owning B.U.:       USA


Abstract: ECA025: NETFINITY 5000 - HOT SWAP BACKPLANE REPLACEMENT


PURPOSE:

This ECA provides for the replacement of hot swap backplanes in a limited number of Netfinity 5000 systems.

This ECA is "MANDATORY".

To order this ECA, contact your IBM Branch Office, Central Response Office or Designated Country ECA Coordinator.

FEATURES:

  Type,                  Machines Affected
  Model,   With          and/or Feature/Device     B/M to be    Service  System
  Stage    B/M           Description               Installed    Hours    Hours
  8659     B/M0000000    NETFINITY 5000 SERVER,    B/M61H3254   01.0     00.6
                         RACK MODELS: 1SY, 2SY,
                         3RY AND 4RY.
                         TOWER MODELS: 12Y,22Y,    B/M61H3255   01.0     00.6
                         31Y AND 41Y.


PHYSICAL CHECK:


     SET 1:
         RACK Models  - FRU P/N 20L1434
         TOWER Models - FRU P/N 20L1435
         -------------= OR =-----------
     SET 2:
         RACK Models  - FRU P/N 61H3248
         TOWER Models - FRU P/N 61H3249
                    -= AND =-
         - The system's serial number begins with 55-xxxxx.
                    -= AND =-
         - The backplane has NO Mylar Tape located on the
           drive side of the card between the mounting holes
           next to the LED's for J9 & J10.


PREREQUISITES: NONE


COMPANION: NONE


CONCURRENT: NONE


DETAIL:

The FRU number is located on the bottom of the daughterboard that attaches to the hot-swap backplane.

Note: When viewing the FRU number on the Hot Swap Backplane Assembly, you may not see the letters "FRU".

Replace the Hot Swap Backplane Assembly as follows:

       Rack : replace FRU P/N 20L1434 with
              FRU supplied in FBM P/N 61H3254.
       Tower : replace FRU P/N 20L1435 with
               FRU supplied in FBM P/N 61H3255.


Refer to the HMM section "Hot Swap Backplane Assembly Removal" for instructions on removing the backplane assembly.

The following must be replaced:

FRU P/N 20L1434 (rack model)
FRU P/N 20L1435 (tower model)

The following may be replaced if both conditions apply:

FRU P/N 61H3248
FRU P/N 61H3249

       Condition 1 = NO Mylar Tape located on the drive
                     side of the card between the mounting
                     holes next to the LED's for J9 & J10.
       Condition 2 = Serial Number starts with "55".


NOTES:

This ECA is "MANDATORY".
This ECA is scheduled to be withdrawn JUNE 30, 2005.

Parts in "Features" Section, under "B/M to be Installed" column, MAY BE Ordered Code "B" or "X".

The removed parts are the property of IBM and should be returned as per your country guidelines and local branch office procedures.

USA:
IBM PSS/TSS CE's should record all time and parts to Service Code 33, ECA025, Other Office 990.
Travel Time = 0.8Hrs.

USA Business Partners: Warranty claims for ECA Reimbursement should be submitted via ECLAIM using Type Service 0E. Refer to the Service Support Guide (SSG) for details.


EMEA:
IBM PSS CE's should record all time and parts to Service Code 33, (8659) ECA025, Other Office 990.
Travel Time = 0.8Hrs.

EMEA Business Partners: Refer to Warranty Claim System; Use Emergency Claim 5 (ECA) and enter into CPPS:
ECA Number 025
Machine Type 8659.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.