FALSE CPU FAILURE AT POST


 Subject: PC Server 704: False CPU Failure at POST (Updated 2/17/97)
  The following RETAIN tip was updated with a new POST error code:
  * New POST error code = 0960 Watchdog Timeout has occurred *
  --------------------------------------------------------------------
    Record number:       H134786
    Device:              D/T8650
    Date created:        96/10/29
    Date last altered:   97/11/04
  See ECA013
 Abstract: SERVER 704: FALSE CPU FAILURE AT POST
 SYMPTOM:
  The PC Server 704 displays any of the following POST messages:
  0176 Previous CPU Failure - Slot 1, CPU #1
  0178 Previous CPU Failure - Slot 2, CPU #1
  0180 Attempting to boot with failed CPU
  -OR- depending on the number of processors, the following POST
       messages (or something similar) may appear:
  0177 Previous CPU Failure - Slot 1, CPU #2
  0179 Previous CPU Failure - Slot 2, CPU #2
  0181 BSP switched, system may be in uniprocessor mode
  -OR-
  0960  Watchdog Timeout has occurred
 PROBLEM ISOLATION AIDS: NONE
 FIX:
 ---------------------------------------------------------

   It is a REQUIREMENT that ECA013 is
 applied to the Server - PRIOR to applying this TIP.
 ---------------------------------------------------------
 Follow this procedure to put the processors back on-line:
  1. Boot to the Setup utility by pressing <F1> during the memory count.
  2. Load Setup Defaults by pressing <F5> <Enter>.
  3. Save and Exit by pressing <F10> <Enter>.
  -OR-
     Reset NVRAM (CMOS) with switch S6A1-1.  Refer to the procedure
     Resetting NVRAM and the RTC
     (on pages 109-110 in the PC Server 704 HMM, publication number
     S78H-6414-00.)
  4. Power off the Server
  5. Disconnect the I2C cable FRU P/N 75H9051 from connector J10
     on the power distribution board.
  6. Restart the Server.
 This action resets system register settings to their default values.
 If the errors continue after restoring the system defaults,
 and after disconnecting the I2C cable
 continue with normal problem determination procedures.
 NOTE:
  With the I2C cable disconnected, the System Drive-fault LED will
  be disabled, but the individual Hard Disk Fault LEDs will
  function normally.