Record number: H106654
Device: D/T8644 Service code: 33
ECA number: ECA019 Parts source: LOC
EC number: EC000000 Publish flag: R
Mandatory: N Hit count: UHC00000
Automatic shipment: N Success count: USC0000
Availability date: 98/05 Publication code: PC50
Plant of control: 23 Date created: O98/04/21
Tip key: Date last altered: A98/05/08
Owning B.U.: USA
Abstract: ECA019: PLANAR REPLACEMENT FOR 333MHZ PROCESSOR UPGRADE
PURPOSE:
This ECA provides for the replacement of the System Planar in
Netfinity 3500, type 8644-1xx/2xx systems that are being upgraded with 333MHz processor(s).
This ECA is Fix-as-Required
This ECA will expire November 30, 2004.
Features:
Type, Machines Affected
Model, With and/or Feature/Device B/M to be Service System
Stage B/M Description Installed Hours Hours
USA:
8644 B/M0000000 NEFINITY SERVER TYPE B/M0000000 01.5 01.0
8644 MODEL 10U, 20U,
21U, 29U, 10X, 20X,
21X WITH PLANAR FRU
93H7269
EMEA:__SAME SYSTEMS
TRAVEL PER SITE: 0.8HR
SERVICE
PER SYSTEM: 1.5HR
PHYSICAL CHECK:
All of the following must be true for this ECA to apply:
-----------OR----------------
The System experiences hangs w/ no video after upgrading to one or two 333MHz Processors.
___________________________________________
| ||||||||||||||||||||||||||||||||||||||||| |
| xxx01k3135xxxxxxxxxxxx xxx | Bar Code Label
|___________________________________________|
PREREQUISITES:
NONE.
COMPANION:
See RETAIN Record H012700 for related Symptoms / Fix on the 233 and 266MHz Systems.
See RETAIN Record H163554 for ECA018 instructions to Flash the system BIOS to revision level 29a or higher.
CONCURRENT:
DETAIL:
Engage the following procedure if the System holds true to the Physical Check Criteria section
of this document:
NOTE: The required System Planar FRU P/N 08L0046 ships with
a Netfinity 3500 BIOS Flash Update Diskette version 1.29, revision 29a (or higher).
---------------------------------------------------------------
Planar Replacement and Processor Upgrade:
Microprocessor Speed Switch Settings:
Switch # 12A1
_______________
|1 2 3 4 5 6 7 8| Note: Leave 5,6,7,8
On |X X | in their default
Off | X X | positions.
|_______________|
NOTE:
When installing the replacement Planar FRU P/N 08L0046, care must be taken to avoid bending
the metal "fingers" on the EMC shield.
When properly seated, thin metal "fingers" will be in place over the USB, mouse/keyboard, and Ethernet port connectors.
For installation of the System Planar, first, angle the System Planar downward and under the EMC shield "fingers"
to prevent bending or damaging the "fingers."
BIOS Update:
*****************************************************
DO NOT DISTURB THE BIOS FLASH PROGRAM UNLESS PROMPTED
*****************************************************
Initialization and Setting Defaults:
EMEA:
IBM PSS CE's should record all time and parts to Service Code 33, ECA019, Other Office 990.
Business Partners use warranty claim type 5 (ECA), and quote ECA number SK (2 character code used due to CPPS restrictions).
Dealer Information:
USA:
Customers may arrange to have this ECA installed by calling 1-800-IBM-SERV. Request that ECA019 be installed.
This ECA is only required if upgrading the Netfinity 3500 server to 333mhz, and does not include the 333Mhz Option
P/N 01K8025, and will not be applied unless proof of purchase for the Option is provided.
Please see the LEGAL - Trademark notice.