Record number: H163815
Device: D/T6898
Model: M
Hit count: UHC00029
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/06/01
Date last altered: A98/06/15
Owning B.U.: USA
Abstract: SCSI BIOS Error: "SCSI Termination NOT FOUND"
SYMPTOM:
When booting the system, the SCSI BIOS returns the following, or similar error message:
"SCSI Termination Not Found"
The SCSI subsystem will not be enabled.
PROBLEM ISOLATION AIDS:
This tip applies to IBM IntelliStation M-Pro Series 6898 and
Netfinity 3500 Series 8644 systems.
The "SCSI Termination Not Found" error message will manifest
itself as an "out-of-box" error in new systems preconfigured for SCSI operation.
In systems preconfigured for IDE operation, the SCSI error
message may not be seen until the on-board SCSI BIOS is enabled in the F1 Setup utility, and a SCSI hardfile is installed.
Planar FRU numbers exposed to this condition are P/N 93H7269 and P/N 08L0046 (for 333MHz Models).
FIX:
Follow normal problem determination steps to eliminate possible
SCSI adapter, SCSI cable, or SCSI hardfile errors.
If the "SCSI Termination Not Found" error persists, replace the system board with FRU P/N 08L0606.
Note: When servicing Netfinity 3500, Type 8644-1xx/2xx systems,
see Retain Tip H106654 for instructions on planar replacement, and saving the CMOS configuration.