Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

PREVENT FALSE DDD ERRORS ON SERVER HARD DRIVES



Oct-1996 - USA=A, EMA=A, AFE=A

Prevent FALSE DDD ERRORS on SERVER HARD Drives
 SYMPTOM: 
 Hard drives in machine types 8640, 8641, 8642, and 9595 appear
 DDD.  The "Replace/Rebuild" function in the RAIDADM utility or
 on the RAID Option Diskette completes successfully without
 physically replacing the drive(s).  No hardware failure actually
 occurs, this is a false DDD.
 PROBLEM ISOLATION AIDS: 
 The following hard drives in both RAID and non-RAID Servers will
 be updated with the firmware update:
   1GB FRU P/N 06H8560  (Option p/n 07H0386)
   2GB FRU P/N 06H8561  (Option p/n 07H0387)
   4GB FRU P/N 06H8562  (Option p/n 07H0834)
 The simplest way to identify the drives is to remove the system
 cover and view the front of the drives.  These drives have a
 silver seal around them.
 FIX: 
 The IBM Hard Disk Drive Update Utility Version 4.1 (C43.EXE)
 updates the firmware on the silver hard drives connected to all
 IBM SCSI-2 adapters (including RAID adapters) and integrated
 SCSI-2 controllers supported in PC Servers except the ServeRAID
 adapter (FRU p/n06H9334).  Servers manufactured with the
 ServeRAID adapter do NOT require the hard drive update.
 Hard drives with firmware 81K6 will be updated to 6C43.
 Hard drives with firmware other than 81K6 will NOT be updated.
 The firmware level of the drives can be viewed on the Drive
 Information screen on Main Menu of RAID Option Diskette.
 Note:
 If dissimilar SCSI adapters are installed, or if the Server
 has an integrated SCSI controller (PCI/MicroChannel Servers)
 and a SCSI-2 adapter (including RAID), then the utility will
 only update the hard drives attached to the primary SCSI
 adapter.  Therefore, the utility must be run separately for
 each type of adapter.
 Follow this procedure: 
  1.  Download C43.EXE from the IBM PC Company BBS and expand the
      image onto a blank diskette using the command: C43.EXE  A:
  2.  Ensure that the customer has a current backup of all data.
  3.  Shutdown the operating system.
  4.  Boot the Server using the firmware diskette.
  5.  An error message may appear as different device drivers
      load.  This is normal.  Wait for the update to complete.
  6.  Power off the Server.
  7.  If the Server has dissimilar SCSI adapters or an integrated
      SCSI controller (PCI/MCA systems), remove the primary SCSI
      adapter or disable the integrated SCSI controller by moving
      the system board jumper J26 to pins 2-3 (adapter position).
      Reboot the Server using the firmware diskette and the drives
      connected to the secondary adapter(s) will be updated.
  8.  After the update is complete, remove the diskette and power
      off the server.
  9.  Replace any adapters removed or return jumper J26 to its
      original position.
 Notes:
  1.  The following message:
      Hard Disk Drive updates complete.
      Remove the diskette, turn off the system power and back on
      to activate the update.  Thank you.

      indicates that hard drives connected to the PRIMARY
      (similar) SCSI adapter(s) were updated.
      Make certain that hard drives connected to secondary
      (dissimilar) SCSI adapter(s), if any, are also updated.
      See step 7 above.
  2.  If the message:
      No hard disk drives requiring firmware update are present
      appears, then either no hard drives require the update,
      OR the hard drives are connected to secondary (dissimilar)
      adapter OR the integrated SCSI controller (PCI/Microchannel Servers)
      needs to be disabled.
 The C43.EXE image is available on the IBM PC Company BBS
 or via the Internet at URL  http://www.pc.ibm.com/files.html  


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.