Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

162/163 error after configuration change



PROBLEM
  1.   162/163 configuration error may occur after a configuration change.
  2.   12902 error after running diagnostics may occur following a configuration change.

Machines AFFECTED - All 6382/S, 6384/D, and 6387/T's.

SOLUTION -
  1.  A FLASH update diskette (level 51 or higher) and a new version of diagnostics (version  are required to fix this problem.  the FLASH update diskette can be obtained from the IBM BBS
  2.  To fix the 12902 error, the diagnostics must be run. Execute the system board test  within the diagnostics to clear the error.

Additional Information - N/A


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.