     IBM-AUSTRIA - PC-HW-Support    30 Aug 1999 | 
 
162/163 error after configuration change
PROBLEM
   -    162/163 configuration error may occur after a configuration change.
   
 -    12902 error after running diagnostics may occur following a configuration change.
 
Machines AFFECTED - All 6382/S, 6384/D, and 6387/T's.
SOLUTION -
   -  A FLASH update diskette (level 51 or higher) and a new version of diagnostics (version
 are required to fix this problem.
 the FLASH update diskette can be obtained from the
IBM BBS
   
 -  To fix the 12902 error, the diagnostics must be run. Execute the system board test
 within the diagnostics to clear the error.
 
Additional Information - N/A
More INFORMATION / HELP is available at the  IBM-HelpCenter
Please see the LEGAL  -  Trademark notice.