Diagnostic Error Code | FRU/Action |
---|---|
000-000-XXX | 1. No action |
BIOS Test Passed | |
000-002-XXX | 1. Flash the system |
BIOS Timeout | 2. System board |
000-024-XXX | 1. Flash the system |
BIOS Addressing failure | 2. System board |
000-025-XXX | 1. Flash the system |
BIOS Checksum Value error | 2. Boot block |
3. System board | |
000-026-XXX | 1. Flash the system |
Flash data error | 2. Boot block |
3. System board | |
000-027-XXX | 1. Run Setup |
BIOS Configuration/Setup error | 2. Flash the system |
3. Boot block | |
4. System board | |
000-034-XXX | 1. Reboot the system |
BIOS Buffer Allocation failure | 2. Flash the system |
3. Run memory test | |
4. System board | |
000-035-XXX | 1. Flash the system |
BIOS Reset Condition detected | 2. System board |
000-036-XXX | 1. Flash the system |
BIOS Register error | 2. Boot block |
3. System board | |
000-038-XXX | 1. Flash the system |
BIOS Extension failure | 2. Adapter card |
3. System board | |
000-039-XXX | 1. Flash the system |
BIOS DMI data error | 2. System board |
000-195-XXX | 1. Information |
BIOS Test aborted by user | 2. Re-start the test, if need to |
000-196-XXX | 1. Depress F3 to review the logfile |
BIOS test halt error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
000-197-XXX | 1. Make sure component that is called out is |
BIOS test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
000-198-XXX | 1. If a component is called out, make sure it is |
BIOS test warning | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
000-199-XXX | 1. Goto 'Undetermined Problem' |
BIOS test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
000-250-XXX | 1. Flash the system |
BIOS APM failure | 2. System board |
000-270-XXX | 1. Flash the system |
BIOS ACP failure | 2. System board |
001-000-XXX | 1. No action |
System Test Passed | |
001-00X-XXX | 1. System board |
System Error | |
001-01X-XXX | 1. System board |
System Error | |
001-024-XXX | 1. System board |
System Addressing test failure | |
001-025-XXX | 1. Flash the system |
System Checksum Value error | 2. System board |
001-026-XXX | 1. Flash the system |
System FLASH data error | 2. System board |
001-027-XXX | 1. Run Setup |
System Configuration/Setup error | 2. FLASH the system |
3. System board | |
001-032-XXX | 1. System board |
System Device Controller failure | |
001-034-XXX | 1. Reboot the system |
System Device Buffer Allocation failure | 2. Flash the system |
3. Run memory test | |
4. System board | |
001-035-XXX | 1. System board |
System Device Reset condition detected | |
001-036-XXX | 1. System board |
System Register error | |
001-038-XXX | 1. Adapter card |
System Extension failure | 2. System board |
001-039-XXX | 1. Flash the system |
System DMIU data structure error | 2. System board |
001-040-XXX | 1. Power-off/on system and re-test |
System IRQ failure | 2. System board |
001-041-XXX | 1. Power-off/on system and re-test |
System DMA failure | 2. System board |
001-195-XXX | 1. Information |
System Test aborted by user | 2. Re-start the test, if need to |
001-196-XXX | 1. Depress F3 to review the logfile |
Systemtest halt, error threshold exceeded | See 'Viewing the Test Log' |
2. Re-start the test to reset the logfile. | |
001-197-XXX | 1. Make sure components that is called out |
Systemtest warning | is enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
001-198-XXX | 1. If a component is called out, make sure |
Systemtest aborted | it is enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
001-199-XXX | 1. Goto 'Undetermined Problem' |
Systemtest failed, cause unknown | 2. Flash the system and re-test |
3. Replace component under function test. | |
001-250-XXX | 1. System board |
System ECC error | |
001-254-XXX | |
001-255-XXX | |
001-256-XXX | |
001-257-XXX | 1. System board |
System DMA error | |
001-260-XXX | |
001-264-XXX | 1. System board |
System IRQ error | |
001-268-XXX | 1. device on IRQ 1 |
System IRQ 1 failure | 2. System board |
001-269-XXX | 1. device on IRQ 2 |
System IRQ 2 failure | 2. System board |
001-270-XXX | 1. device on IRQ 3 |
System IRQ 3 failure | 2. System board |
001-271-XXX | 1. device on IRQ 4 |
System IRQ 4 failure | 2. System board |
001-272-XXX | 1. device on IRQ 5 |
System IRQ 5 failure | 2. System board |
001-273-XXX | 1. Diskette Cable |
System IRQ 6 (diskette drive) failure | 2. Diskette drive |
3. System board | |
001-274-XXX | 1. device on IRQ 7 |
System IRQ 7 failure | 2. System board |
001-275-XXX | 1. device on IRQ 8 |
System IRQ 8 failure | 2. System board |
001-276-XXX | 1. device on IRQ 9 |
System IRQ 9 failure | 2. System board |
001-277-XXX | 1. device on IRQ 10 |
System IRQ 10 failure | 2. System board |
001-278-XXX | 1. device on IRQ 11 |
System IRQ 11 failure | 2. System board |
001-279-XXX | 1. device on IRQ 12 |
System IRQ 12 failure | 2. System board |
001-280-XXX | 1. device on IRQ 13 |
System IRQ 13 failure | 2. System board |
001-281-XXX | 1. Harddisk drive Cable |
System IRQ 14 (harddisk drive) failure | 2. System board |
3. Harddisk drive | |
4. System board | |
001-282-XXX | 1. device on IRQ 15 |
System IRQ 15 failure | 2. System board |
001-286-XXX | |
001-287-XXX | |
001-288-XXX | 1. System board |
System Timer failure | |
001-292-XXX | 1. Run Setup and re-test |
System CMOS RAM error | 2. System board |
001-293-XXX | 1. Battery |
System CMOS Battery | 2. System board |
001-298-XXX | 1. Flash the system |
System RTC date/time update failure | 2. System board |
001-299-XXX | 1. System board |
System RTC periodic interrupt failure | |
001-300-XXX | 1. System board |
System RTC Alarm failure | |
001-301-XXX | 1. Flash the system |
System RTC Century byte error | 2. System board |
005-000-XXX | 1. No action |
Video Test Passed | |
005-00X-XXX | 1. Video card, if installed |
Video error | 2. System board |
005-010-XXX | |
005-011-XXX | |
005-012-XXX | |
005-013-XXX | 1. Video card, if installed |
Video Signal failure | 2. System board |
005-016-XXX | 1. Video RAM |
Video Simple Patterntest failure | 2. Video card, if installed |
3. System board | |
005-024-XXX | 1. Video card, if installed |
Video Addressingtest failure | 2. System board |
005-025-XXX | 1. Video card, if installed |
Video Checksum Value error | 2. System board |
005-027-XXX | 1. Run Setup |
Video Configuration/Setup error | 2. Video drivers update |
3. Video card, if installed | |
4. System board | |
005-031-XXX | 1. Video cable |
Video Device Cable failure | 2. Monitor |
3. Video card, if installed | |
4. System board | |
005-032-XXX | 1. Video card, if installed |
Video Device Controller failure | 2. System board |
005-036-XXX | 1. Video card, if installed |
Video Register error | 2. System board |
005-038-XXX | 1. Video card, if installed |
System BIOS extension failure | 2. System board |
005-040-XXX | 1. Video card, if installed |
Video IRQ failure | 2. System board |
005-195-XXX | 1. Information |
Video Test aborted by user | 2. Re-start the test, if needed |
005-196-XXX | 1. Depress F3 to review the logfile |
Videotest halt, error threshold exceeded | See 'Viewing the Test Log' |
2. Re-start the test, to reset the logfile | |
005-197-XXX | 1. Make sure component that is called out |
Videotest warning | is enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
005-198-XXX | 1. If a component is called out, make sure |
Videotest aborted | it is enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
005-199-XXX | 1. Goto 'Undetermined Problem' |
Videotest failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under functiontest | |
005-2XX-XXX | |
005-3XX-XXX | 1. Videocard if installed |
Videosubsystem error | 2. System board |
006-000-XXX | 1. No action |
Diskette interface Test Passed | |
006-0XX-XXX | 1. Diskette drive Cable |
Diskette interface error | 2. Diskette drive |
3. System board | |
006-195-XXX | 1. Information |
Diskette interface test aborted by user | 2. Re-start the test, if need to |
006-196-XXX | 1. Depress F3 to review the logfile |
Diskette interface test halt, | See 'Viewing the Test Log' |
error threshold exceeded | 2. Re-start the test to reset the logfile. |
006-197-XXX | 1. Make sure component that is called out |
Diskette interface warning | is enabled and/or connected |
2. Re-run test | |
3. Component that is calledout in warning statement | |
4. Component under test | |
006-198-XXX | 1. If a component is called out, make sure |
Diskette interface test aborted | it is enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
006-199-XXX | 1. Goto 'Undetermined Problem' |
Diskette interface test failed | 2. Flash the system and re-test |
cause unknown | 3. Replace component under function test |
006-25X-XXX | 1. Diskettedrive Cable |
Diskette interface Error | 2. Diskette drive |
3. System board | |
011-000-XXX | 1. No action |
Serialport Interface Test Passed | |
011-001-XXX | 1. Remove external serial device, if present |
Serialport Presence | 2. Run setup, enable port |
3. System board | |
011-002-XXX | |
011-003-XXX | 1. System board |
Serialport Timeout/Parity error | |
011-013-XXX | |
011-014-XXX | 1. System board |
Serialport Control | |
Signal/Loopback test failure | |
011-015-XXX | 1. Wrap plug |
Serialport External | 2. System board |
Loopback test failure | |
011-027-XXX | 1. Run Setup, enable port |
Serialport | 2. Flash the system |
Configuration/Setuperror | 3. System board |
011-03X-XXX | |
011-04X-XXX | 1. System board |
Serialport failure | |
011-195-XXX | 1. Information |
Serialport Test aborted by user | |
2. Re-start the test, if need to | |
011-196-XXX | 1. Depress F3 to review the logfile |
Serial test halt, error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
011-197-XXX | 1. Make sure component that is called out is |
Serial port test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
011-198-XXX | 1. If a component is called out, make sure |
Serial port test aborted | it is enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
011-199-XXX | 1. Goto 'Undetermined Problem' |
Serial port test failed, cause unknown | 2. Flash the system and re-test |
3. Replace component under function test. | |
011-2XX-XXX | 1. External serial device |
Serial port signal failure | 2. System board |
014-000-XXX | 1. No action |
Parallel port Interface Test Passed | |
014-001-XXX | 1. Remove external Parallel device, if present |
Parallel port Presence | 2. Run setup, enable port |
3. System board | |
014-002-XXX | |
014-003-XXX | 1. System board |
Parallelport Timeout/Parity error | |
014-013-XXX | |
014-014-XXX | 1. System board |
Parallelport Control | |
Signal/Loopback test failure | |
014-015-XXX | 1. Wrap plug |
Parallelport External | 2. System board |
Loopback test failure | |
014-027-XXX | 1. Run Setup, enable port |
Parallelport | 2. Flash the system |
Configuration/Setuperror | 3. System board |
014-03X-XXX | |
014-04X-XXX | 1. System board |
Parallelport failure | |
014-195-XXX | 1. Information |
Parallelport Test aborted by user | |
2. Re-start the test, if need to | |
014-196-XXX | 1. Depress F3 to review the logfile |
Parallel port test halt, error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
014-197-XXX | 1. Make sure component that is called out is |
Parallel port test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
014-198-XXX | 1. If a component is called out, make sure |
Parallel port test aborted | it is enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
014-199-XXX | 1. Goto 'Undetermined Problem' |
Parallel port test failed, cause unknown | 2. Flash the system and re-test |
3. Replace component under function test. | |
014-2XX-XXX | |
014-3XX-XXX | 1. External parallel device |
Parallel port signal failure | 2. System board |
015-000-XXX | 1. No action |
USB port Interface Test Passed | |
015-001-XXX | 1. Remove USB device(s) and re-test |
USB port Presence | 2. System board |
015-002-XXX | 1. Remove USB device(s) and re-test |
USB port Timeout | 2. System board |
015-015-XXX | 1. Remove USB Device(s) and re-test |
USB port External | 2. System board |
Loopback test failure | |
015-027-XXX | 1. Flash the system |
USB port Configuration/Setup error | 2. System board |
015-032-XXX | 1. System board |
USB port Device Controller failure | |
015-034-XXX | 1. Reboot the system |
USB port buffer allocation failure | 2. Flash the system |
3. Run memory test | |
4. System board | |
015-035-XXX | 1. Remove USB Device(s) and re-test |
USB port Reset condition detected | |
2. System board | |
015-036-XXX | 1. System board |
USB port Register error | |
015-040-XXX | 1. Run setup and check for conflicts |
USB port IRQ failure | enabled and/or connected |
2. Flash the system | |
3. System board | |
015-195-XXX | 1. Information |
USB port Test aborted by user | 2. Re-start the test, if need to |
015-196-XXX | 1. Depress F3 to review the logfile |
USB port test halt, error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
015-197-XXX | 1. Make sure component that is called out is |
USB port test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
015-198-XXX | 1. If a component is called out, make sure |
USB port test aborted | it is enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
015-199-XXX | 1. Goto 'Undetermined Problem' |
USB port test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
018-000-XXX | 1. No action |
PCI Card Test Passed | |
018-0XX-XXX | 1. PCI Card |
PCI Card Failure | 2. Riser card, if installed |
3. System board | |
018-195-XXX | 1. Information |
PCI card Test aborted by user | 2. Re-start the test, if need to |
018-196-XXX | 1. Depress F3 to review the logfile |
PCI Card test halt, error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
018-197-XXX | 1. Make sure component that is called out is |
PCI Card test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
018-198-XXX | 1. If a component is called out, make sure |
PCI Card test aborted | it is enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
018-199-XXX | 1. Goto 'Undetermined Problem' |
PCI Card test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
018-250-XXX | 1. PCI card |
PCI Card Service error | 2. Riser card, if installed |
3. System board | |
020-000-XXX | 1. No action |
PCI Interface Test Passed | |
020-0XX-XXX | 1. PCI card |
PCI Interface error | 2. Riser card, if installed |
3. System board | |
020-195-XXX | 1. Information |
PCI Test aborted by user | 2. Re-start the test, if need to |
020-196-XXX | 1. Depress F3 to review the logfile |
PCI test halt, error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
020-197-XXX | 1. Make sure component that is called out is |
PCI test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
020-198-XXX | 1. If a component is called out, make sure |
PCI test aborted | it is enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
020-199-XXX | 1. Goto 'Undetermined Problem' |
PCI test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
020-262-XXX | 1. PCI card |
PCI system error | 2. Riser card, if installed |
3. System board | |
025-000-XXX | 1. No action |
IDE interface Test Passed | |
025-00X-XXX | |
025-01X-XXX | 1. IDE signal cable |
IDE interface failure | 2. Check power supply |
3. IDE device | |
4. System board | |
025-027-XXX | 1. IDE signal cable |
IDE interface | 2. Flash the system |
Configuration/Setup error | 3. IDE device |
4. System board | |
025-02X-XXX | |
025-03X-XXX | |
025-04X-XXX | 1. IDE signal cable |
IDE interface failure | 2. Check power supply |
3. IDE device | |
4. System board | |
025-195-XXX | 1. Information |
IDE interface Test aborted by user | 2. Re-start the test, if need to |
025-196-XXX | 1. Depress F3 to review the logfile |
IDE interface test halt error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
025-197-XXX | 1. Make sure component that is called out is |
IDE interface test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
025-198-XXX | 1. If a component is called out, make sure it is |
IDE interface test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
025-199-XXX | 1. Goto 'Undetermined Problem' |
IDE interface test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
030-000-XXX | 1. No action |
SCSI interface Test Passed | |
030-00X-XXX | |
030-01X-XXX | 1. SCSI signal cable |
SCSI interface failure | 2. Check power supply |
3. SCSI device | |
4. SCSI adapter card, if installed | |
5. System board | |
030-027-XXX | 1. SCSI signal cable |
SCSI interface | 2. Flash the system |
Configuration/Setup error | 3. SCSI device |
4. SCSI adapter card, if installed | |
5. System board | |
030-03X-XXX | |
030-04X-XXX | 1. SCSI signal cable |
SCSI interface failure | 2. Check power supply |
3. SCSI device | |
4. SCSI adapter card, if installed | |
5. System board | |
030-195-XXX | 1. Information |
SCSI interface Test aborted by user | 2. Re-start the test, if need to |
030-196-XXX | 1. Depress F3 to review the logfile |
SCSI interface test halt error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
030-197-XXX | 1. Make sure component that is called out is |
SCSI interface test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
030-198-XXX | 1. If a component is called out, make sure it is |
SCSI interface test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
030-199-XXX | 1. Goto 'Undetermined Problem' |
SCSI interface test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
035-000-XXX | 1. No action |
RAID interface Test Passed | |
035-0XX-XXX | 1. RAID signal cable |
RAID interface failure | 2. RAID device |
3. RAID adapter card, if installed | |
4. System board | |
035-195-XXX | 1. Information |
RAID interface Test aborted by user | 2. Re-start the test, if need to |
035-196-XXX | 1. Depress F3 to review the logfile |
RAID interface test halt error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
035-197-XXX | 1. Make sure component that is called out is |
RAID interface test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
035-198-XXX | 1. If a component is called out, make sure it is |
RAID interface test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
035-199-XXX | 1. Goto 'Undetermined Problem' |
RAID interface test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
071-000-XXX | 1. No action |
Audio port interface Test Passed | |
071-00X-XXX | |
071-01X-XXX | |
071-02X-XXX | 1. Run Setup |
Audio port error | 2. Flash the system |
3. System board | |
071-03X-XXX | 1. Speakers |
Audio port failure | 2. Microphone |
3. Audio card, if installed | |
4. System board | |
071-04X-XXX | 1. Run Setup |
Audio port failure | 2. Audio card, if installed |
3. System b*ard | |
071-195-XXX | 1. Information |
Audio port Test aborted by user | 2. Re-start the test, if need to |
071-196-XXX | 1. Depress F3 to review the logfile |
Audio port test halt error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
071-197-XXX | 1. Make sure component that is called out is |
Audio port test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
071-198-XXX | 1. If a component is called out, make sure it is |
RAID interface test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
071-199-XXX | 1. Goto 'Undetermined Problem' |
Audio port test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
071-25X-XXX | 1. Speakers |
Audio port failure | 2. Audio card, if installed |
3. Aystem board | |
080-000-XXX | 1. No action |
Game port interface Test Passed | |
080-XXX-XXX | 1. Remove the game port device and re-test the system |
Game port interface error | |
080-195-XXX | 1. Information |
Game port interface Test aborted by user | 2. Re-start the test, if need to |
080-196-XXX | 1. Depress F3 to review the logfile |
Game port interface test halt error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
080-197-XXX | 1. Make sure component that is called out is |
Game port interface test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
080-198-XXX | 1. If a component is called out, make sure it is |
Game Port interface test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
080-199-XXX | 1. Goto 'Undetermined Problem' |
Game Port interface test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
086-000-XXX | 1. No action |
Mouse port interface Test Passed | |
086-001-XXX | 1. Mouse |
Mouse Port interface Presence | 2. System board |
086-032-XXX | 1. Mouse |
Mouse Port interface | 2. System board |
Device controller failure | |
086-035-XXX | 1. Mouse |
Mouse Port interface Reset | 2. System board |
086-040-XXX | 1. Run Setup |
Audio port interface IRQ failure | 2. Mouse |
3. System board | |
086-195-XXX | 1. Information |
Mouse Port interface Test | 2. Re-start the test, if need to |
aborted by user | |
086-196-XXX | 1. Depress F3 to review the logfile |
Mouse Port interface test halt, error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
086-197-XXX | 1. Make sure component that is called out is |
Mouse Port interface test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
086-198-XXX | 1. If a component is called out, make sure it is |
Mouse Port interface test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
086-199-XXX | 1. Goto 'Undetermined Problem' |
Mouse Port interface test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
089-000-XXX | 1. No action |
Microprocessor Test Passed | |
089-XXX-XXX | 1. Micrprocessor(s) |
Microprocessor failure | 2. System board |
089-195-XXX | 1. Information |
Microprocessor test aborted by user | 2. Re-start the test, if need to |
089-196-XXX | 1. Depress F3 to review the logfile |
Microprocessor test halt error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
089-197-XXX | 1. Make sure component that is called out is |
Microprocessor test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
089-198-XXX | 1. If a component is called out, make sure it is |
Microprocessor test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
089-199-XXX | 1. Goto 'Undetermined Problem' |
Microprocessor test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
170-000-XXX | 1. No action |
Voltage Sensor(s) Test Passed | |
170-0XX-XXX | 1. Flash system |
Voltage Sensor(s) failure | 2. System board |
170-195-XXX | 1. Information |
Voltage Sensor(s) Test | 2. Re-start the test, if need to |
aborted by user | |
170-196-XXX | 1. Depress F3 to review the logfile |
Voltage Sensor(s) test halt, error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
170-197-XXX | 1. Make sure component that is called out is |
Voltage Sensor(s) test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
170-198-XXX | 1. If a component is called out, make sure it is |
Voltage Sensor(s) test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
170-199-XXX | 1. Goto 'Undetermined Problem' |
Voltage Sensor(s) test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
170-254-XXX | 1. Voltage Regulator Module (VRM) |
Voltage Sensor(s) Voltage | 2. Microprocessor |
Regulator Module error | 3. System board |
175-000-XXX | 1. No action |
Thermal Sensor(s) Test Passed | |
175-0XX-XXX | 1. Flash system |
Thermal Sensor(s) failure | 2. System board |
175-195-XXX | 1. Information |
Thermal Sensor(s) Test aborted by user | 2. Re-start the test, if need to |
175-196-XXX | 1. Depress F3 to review the logfile |
Thermal Sensor(s) test halt, error | See 'Viewing the Test Log'. |
threshold exceeded. | 2. Re-start the test to reset the logfile. |
175-197-XXX | 1. Make sure component that is called out is |
Thermal Sensor(s) test warning | enabled and/or connected |
2. Re-run test | |
3. Component that is called out in warning statement | |
4. Component under test | |
175-198-XXX | 1. If a component is called out, make sure it is |
Thermal Sensor(s) test aborted | enabled and/or connected |
2. Flash the system and re-test | |
3. Goto 'Undetermined Problem' | |
175-199-XXX | 1. Goto 'Undetermined Problem' |
Thermal Sensor(s) test failed, cause unknown | 2. Flash the system and re-test |
3. Replace components under function test | |
175-250-XXX | |
175-251-XXX | 1. Check fans |
Thermal Sensor(s) limit error | 2. Check Power supply |
3. Microprocessor | |
4. System board | |
185-000-XXX | 1. No action |
Asset Security Test Passed | |
185-XXX-XXX | 1. Assure Asset Security Enabled |
Asset Security failure | 2. Flash system |
3. System board | |
185-278-XXX | 1. C2 Coverswitch |
Asset Security Chassis Intrusion | 2. System board |
201-000-XXX | 1. No action |
System Memory Test Passed | |
201-XXX-XXX | 1. Replace the memory called out by the test |
System Memory error | 2. System board |
202-000-XXX | 1. No action |
System Cache Test Passed | |
202-XXX-XXX | 1. Cache, if removable |
System Cache error | 2. System board |
3. Microprocessor | |
206-000-XXX | 1. No action |
Diskette Drive Test Passed | |
206-XXX-XXX | 1. Diskette Drive Cable |
Diskette Drive error | 2. Check power supply voltages |
3. Diskette drive | |
4. System board | |
215-000-XXX | 1. No action |
CD-ROM Drive Test Passed | |
215-XXX-XXX | 1. CD-ROM Drive Cable |
CD-ROM Drive error | 2. Check power supply voltages |
3. CD-ROM drive | |
4. System board | |
217-000-XXX | 1. No action |
Hard Disk Drive Test Passed | |
217-25X-XXX | |
217-26X-XXX | 1. CD-ROM Drive Cable |
Hard Disk Drive (IDE) error | 2. Check power supply voltages |
3. Hard Disk drive (IDE) | |
4. System board | |
217-28X-XXX | |
217-29X-XXX | 1. CD-ROM Drive Cable |
Hard Disk Drive (SCSI) error | 2. Check power supply voltages |
3. Hard Disk drive (SCSI) | |
4. SCSI adapter card | |
5. System board | |
220-000-XXX | 1. No action |
Hi-Capacity Cartridge Drive Test Passed | |
220-XXX-XXX | 1. Remove the Hi-Capacity Cartridge |
Hi-Capacity Cartridge Drive error | Drive and re-test the system |
301-000-XXX | 1. No action |
Keyboard Test Passed | |
301-XXX-XXX | 1. Keyboard |
Keyboard error | 2. Check and test the Mouse |
3. System board | |
302-000-XXX | 1. No action |
Mouse Test Passed | |
302-XXX-XXX | 1. Mouse |
Keyboard error | 2. Check and test the Keyboard |
3. System board | |
303-000-XXX | 1. No action |
Joystick Test Passed | |
303-XXX-XXX | 1. Remove the Joystick and re-test the system |
Joystick error | |
305-000-XXX | 1. No action |
Monitor DDC Test Passed | |
305-250-XXX | 1. Run Setup to enable DDC |
Monitor DDC selftest failure | 2. Cable |
3. Monitor | |
4. Video card | |
5. System board | |
415-000-XXX | 1. No action |
Modem Test Passed | |
415-XXX-XXX | 1. Remove the Modem and re-test the system |
Modemerror |
Please see the LEGAL - Trademark notice.