Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Diagnostic Error Codes



  Diagnostic Error Codes (PC-Doctor)

Refer to the following Diagnostic Error Codes when using the IBM PC Enhanced Diagnostics test.
See 'Diagnostics Test Programs' for information about the IBM PC Enhanced Diagnostics program.


In the following index, X can represent any number.

Diagnostic Error Code    FRU/Action
  
000-000-XXX 1. No action
BIOS Test Passed
000-002-XXX 1. Flash the system
BIOS Timeout 2. System board
  
000-024-XXX 1. Flash the system
BIOS Addressing failure 2. System board
  
000-025-XXX 1. Flash the system
BIOS Checksum Value error 2. Boot block
  3. System board
  
000-026-XXX 1. Flash the system
Flash data error 2. Boot block
  3. System board
  
000-027-XXX 1. Run Setup
BIOS Configuration/Setup error 2. Flash the system
  3. Boot block
  4. System board
  
000-034-XXX 1. Reboot the system
BIOS Buffer Allocation failure 2. Flash the system
  3. Run memory test
  4. System board
  
000-035-XXX 1. Flash the system
BIOS Reset Condition detected 2. System board
  
000-036-XXX 1. Flash the system
BIOS Register error 2. Boot block
  3. System board
  
000-038-XXX 1. Flash the system
BIOS Extension failure 2. Adapter card
  3. System board
  
000-039-XXX 1. Flash the system
BIOS DMI data error 2. System board
  
000-195-XXX 1. Information
BIOS Test aborted by user 2. Re-start the test, if need to
  
000-196-XXX 1. Depress F3 to review the logfile
BIOS test halt error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
000-197-XXX 1. Make sure component that is called out is
BIOS test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
000-198-XXX 1. If a component is called out, make sure it is
BIOS test warning     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
000-199-XXX 1. Goto 'Undetermined Problem'
BIOS test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
000-250-XXX 1. Flash the system
BIOS APM failure 2. System board
  
000-270-XXX 1. Flash the system
BIOS ACP failure 2. System board
  
001-000-XXX 1. No action
System Test Passed
001-00X-XXX 1. System board
System Error
001-01X-XXX 1. System board
System Error
001-024-XXX 1. System board
System Addressing test failure
001-025-XXX 1. Flash the system
System Checksum Value error 2. System board
  
001-026-XXX 1. Flash the system
System FLASH data error 2. System board
  
001-027-XXX 1. Run Setup
System Configuration/Setup error 2. FLASH the system
  3. System board
  
001-032-XXX 1. System board
System Device Controller failure
001-034-XXX 1. Reboot the system
System Device Buffer Allocation failure 2. Flash the system
  3. Run memory test
  4. System board
  
001-035-XXX 1. System board
System Device Reset condition detected
001-036-XXX 1. System board
System Register error
001-038-XXX 1. Adapter card
System Extension failure 2. System board
  
001-039-XXX 1. Flash the system
System DMIU data structure error 2. System board
  
001-040-XXX 1. Power-off/on system and re-test
System IRQ failure 2. System board
  
001-041-XXX 1. Power-off/on system and re-test
System DMA failure 2. System board
  
001-195-XXX 1. Information
System Test aborted by user 2. Re-start the test, if need to
  
001-196-XXX 1. Depress F3 to review the logfile
Systemtest halt, error threshold exceeded     See 'Viewing the Test Log'
  2. Re-start the test to reset the logfile.
  
001-197-XXX 1. Make sure components that is called out
Systemtest warning     is enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
001-198-XXX 1. If a component is called out, make sure
Systemtest aborted     it is enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
001-199-XXX 1. Goto 'Undetermined Problem'
Systemtest failed, cause unknown 2. Flash the system and re-test
  3. Replace component under function test.
  
001-250-XXX 1. System board
System ECC error
001-254-XXX
001-255-XXX
001-256-XXX
001-257-XXX 1. System board
System DMA error
001-260-XXX
001-264-XXX 1. System board
System IRQ error
001-268-XXX 1. device on IRQ 1
 
System IRQ 1 failure 2. System board
  
001-269-XXX 1. device on IRQ 2
System IRQ 2 failure 2. System board
  
001-270-XXX 1. device on IRQ 3
System IRQ 3 failure 2. System board
  
001-271-XXX 1. device on IRQ 4
System IRQ 4 failure 2. System board
  
001-272-XXX 1. device on IRQ 5
System IRQ 5 failure 2. System board
  
001-273-XXX 1. Diskette Cable
System IRQ 6 (diskette drive) failure 2. Diskette drive
  3. System board
  
001-274-XXX 1. device on IRQ 7
System IRQ 7 failure 2. System board
  
001-275-XXX 1. device on IRQ 8
System IRQ 8 failure 2. System board
  
001-276-XXX 1. device on IRQ 9
System IRQ 9 failure 2. System board
  
001-277-XXX 1. device on IRQ 10
System IRQ 10 failure 2. System board
  
001-278-XXX 1. device on IRQ 11
System IRQ 11 failure 2. System board
  
001-279-XXX 1. device on IRQ 12
System IRQ 12 failure 2. System board
  
001-280-XXX 1. device on IRQ 13
System IRQ 13 failure 2. System board
  
001-281-XXX 1. Harddisk drive Cable
System IRQ 14 (harddisk drive) failure 2. System board
  3. Harddisk drive
  4. System board
  
001-282-XXX 1. device on IRQ 15
System IRQ 15 failure 2. System board
  
001-286-XXX
001-287-XXX
001-288-XXX 1. System board
System Timer failure
001-292-XXX 1. Run Setup and re-test
System CMOS RAM error 2. System board
  
001-293-XXX 1. Battery
System CMOS Battery 2. System board
  
001-298-XXX 1. Flash the system
System RTC date/time update failure 2. System board
  
001-299-XXX 1. System board
System RTC periodic interrupt failure
001-300-XXX 1. System board
System RTC Alarm failure
001-301-XXX 1. Flash the system
System RTC Century byte error 2. System board
  
005-000-XXX 1. No action
Video Test Passed
005-00X-XXX 1. Video card, if installed
Video error 2. System board
  
005-010-XXX
005-011-XXX
005-012-XXX
005-013-XXX 1. Video card, if installed
Video Signal failure 2. System board
  
005-016-XXX 1. Video RAM
Video Simple Patterntest failure 2. Video card, if installed
  3. System board
  
005-024-XXX 1. Video card, if installed
Video Addressingtest failure 2. System board
  
005-025-XXX 1. Video card, if installed
Video Checksum Value error 2. System board
  
005-027-XXX 1. Run Setup
Video Configuration/Setup error 2. Video drivers update
  3. Video card, if installed
  4. System board
  
005-031-XXX 1. Video cable
Video Device Cable failure 2. Monitor
  3. Video card, if installed
  4. System board
  
005-032-XXX 1. Video card, if installed
Video Device Controller failure 2. System board
  
005-036-XXX 1. Video card, if installed
Video Register error 2. System board
  
005-038-XXX 1. Video card, if installed
System BIOS extension failure 2. System board
  
005-040-XXX 1. Video card, if installed
Video IRQ failure 2. System board
  
005-195-XXX 1. Information
Video Test aborted by user 2. Re-start the test, if needed
  
005-196-XXX 1. Depress F3 to review the logfile
Videotest halt, error threshold exceeded     See 'Viewing the Test Log'
  2. Re-start the test, to reset the logfile
  
005-197-XXX 1. Make sure component that is called out
Videotest warning     is enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
005-198-XXX 1. If a component is called out, make sure
Videotest aborted     it is enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
005-199-XXX 1. Goto 'Undetermined Problem'
Videotest failed, cause unknown 2. Flash the system and re-test
  3. Replace components under functiontest
  
005-2XX-XXX
005-3XX-XXX 1. Videocard if installed
Videosubsystem error 2. System board
  
006-000-XXX 1. No action
Diskette interface Test Passed
006-0XX-XXX 1. Diskette drive Cable
Diskette interface error 2. Diskette drive
  3. System board
  
006-195-XXX 1. Information
Diskette interface test aborted by user 2. Re-start the test, if need to
  
006-196-XXX 1. Depress F3 to review the logfile
Diskette interface test halt,     See 'Viewing the Test Log'
error threshold exceeded 2. Re-start the test to reset the logfile.
  
006-197-XXX 1. Make sure component that is called out
Diskette interface warning     is enabled and/or connected
  2. Re-run test
  3. Component that is calledout in warning statement
  4. Component under test
  
006-198-XXX 1. If a component is called out, make sure
Diskette interface test aborted     it is enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
006-199-XXX 1. Goto 'Undetermined Problem'
Diskette interface test failed 2. Flash the system and re-test
cause unknown 3. Replace component under function test
  
006-25X-XXX 1. Diskettedrive Cable
Diskette interface Error 2. Diskette drive
  3. System board
  
011-000-XXX 1. No action
Serialport Interface Test Passed
011-001-XXX 1. Remove external serial device, if present
Serialport Presence 2. Run setup, enable port
  3. System board
  
011-002-XXX
011-003-XXX 1. System board
Serialport Timeout/Parity error
011-013-XXX
011-014-XXX 1. System board
Serialport Control
Signal/Loopback test failure
011-015-XXX 1. Wrap plug
Serialport External 2. System board
Loopback test failure
011-027-XXX 1. Run Setup, enable port
Serialport 2. Flash the system
Configuration/Setuperror 3. System board
  
011-03X-XXX
011-04X-XXX 1. System board
Serialport failure
011-195-XXX 1. Information
Serialport Test aborted by user
2. Re-start the test, if need to
011-196-XXX 1. Depress F3 to review the logfile
Serial test halt, error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
011-197-XXX 1. Make sure component that is called out is
Serial port test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
011-198-XXX 1. If a component is called out, make sure
Serial port test aborted     it is enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
011-199-XXX 1. Goto 'Undetermined Problem'
Serial port test failed, cause unknown 2. Flash the system and re-test
  3. Replace component under function test.
  
011-2XX-XXX 1. External serial device
Serial port signal failure 2. System board
  
014-000-XXX 1. No action
Parallel port Interface Test Passed
014-001-XXX 1. Remove external Parallel device, if present
Parallel port Presence 2. Run setup, enable port
  3. System board
  
014-002-XXX
014-003-XXX 1. System board
Parallelport Timeout/Parity error
014-013-XXX
014-014-XXX 1. System board
Parallelport Control
Signal/Loopback test failure
014-015-XXX 1. Wrap plug
Parallelport External 2. System board
Loopback test failure
014-027-XXX 1. Run Setup, enable port
Parallelport 2. Flash the system
Configuration/Setuperror 3. System board
  
014-03X-XXX
014-04X-XXX 1. System board
Parallelport failure
014-195-XXX 1. Information
Parallelport Test aborted by user
2. Re-start the test, if need to
014-196-XXX 1. Depress F3 to review the logfile
Parallel port test halt, error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
014-197-XXX 1. Make sure component that is called out is
Parallel port test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
014-198-XXX 1. If a component is called out, make sure
Parallel port test aborted     it is enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
014-199-XXX 1. Goto 'Undetermined Problem'
Parallel port test failed, cause unknown 2. Flash the system and re-test
  3. Replace component under function test.
  
014-2XX-XXX
014-3XX-XXX 1. External parallel device
Parallel port signal failure 2. System board
  
015-000-XXX 1. No action
USB port Interface Test Passed
015-001-XXX 1. Remove USB device(s) and re-test
USB port Presence 2. System board
  
015-002-XXX 1. Remove USB device(s) and re-test
USB port Timeout 2. System board
  
015-015-XXX 1. Remove USB Device(s) and re-test
USB port External 2. System board
Loopback test failure
015-027-XXX 1. Flash the system
USB port Configuration/Setup error 2. System board
  
015-032-XXX 1. System board
USB port Device Controller failure
015-034-XXX 1. Reboot the system
USB port buffer allocation failure 2. Flash the system
  3. Run memory test
  4. System board
  
015-035-XXX 1. Remove USB Device(s) and re-test
USB port Reset condition detected
2. System board
015-036-XXX 1. System board
USB port Register error
015-040-XXX 1. Run setup and check for conflicts
USB port IRQ failure     enabled and/or connected
  2. Flash the system
  3. System board
  
015-195-XXX 1. Information
USB port Test aborted by user 2. Re-start the test, if need to
  
015-196-XXX 1. Depress F3 to review the logfile
USB port test halt, error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
015-197-XXX 1. Make sure component that is called out is
USB port test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
015-198-XXX 1. If a component is called out, make sure
USB port test aborted     it is enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
015-199-XXX 1. Goto 'Undetermined Problem'
USB port test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
018-000-XXX 1. No action
PCI Card Test Passed
018-0XX-XXX 1. PCI Card
PCI Card Failure 2. Riser card, if installed
  3. System board
  
018-195-XXX 1. Information
PCI card Test aborted by user 2. Re-start the test, if need to
  
018-196-XXX 1. Depress F3 to review the logfile
PCI Card test halt, error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
018-197-XXX 1. Make sure component that is called out is
PCI Card test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
018-198-XXX 1. If a component is called out, make sure
PCI Card test aborted     it is enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
018-199-XXX 1. Goto 'Undetermined Problem'
PCI Card test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
018-250-XXX 1. PCI card
PCI Card Service error 2. Riser card, if installed
  3. System board
  
020-000-XXX 1. No action
PCI Interface Test Passed
020-0XX-XXX 1. PCI card
PCI Interface error 2. Riser card, if installed
  3. System board
  
020-195-XXX 1. Information
PCI Test aborted by user 2. Re-start the test, if need to
  
020-196-XXX 1. Depress F3 to review the logfile
PCI test halt, error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
020-197-XXX 1. Make sure component that is called out is
PCI test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
020-198-XXX 1. If a component is called out, make sure
PCI test aborted     it is enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
020-199-XXX 1. Goto 'Undetermined Problem'
PCI test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
020-262-XXX 1. PCI card
PCI system error 2. Riser card, if installed
  3. System board
  
025-000-XXX 1. No action
IDE interface Test Passed
025-00X-XXX
025-01X-XXX 1. IDE signal cable
IDE interface failure 2. Check power supply
  3. IDE device
  4. System board
  
025-027-XXX 1. IDE signal cable
IDE interface 2. Flash the system
Configuration/Setup error 3. IDE device
  4. System board
  
025-02X-XXX
025-03X-XXX
025-04X-XXX 1. IDE signal cable
IDE interface failure 2. Check power supply
  3. IDE device
  4. System board
  
025-195-XXX 1. Information
IDE interface Test aborted by user 2. Re-start the test, if need to
  
025-196-XXX 1. Depress F3 to review the logfile
IDE interface test halt error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
025-197-XXX 1. Make sure component that is called out is
IDE interface test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
025-198-XXX 1. If a component is called out, make sure it is
IDE interface test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
025-199-XXX 1. Goto 'Undetermined Problem'
IDE interface test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
030-000-XXX 1. No action
SCSI interface Test Passed
030-00X-XXX
030-01X-XXX 1. SCSI signal cable
SCSI interface failure 2. Check power supply
  3. SCSI device
  4. SCSI adapter card, if installed
  5. System board
  
030-027-XXX 1. SCSI signal cable
SCSI interface 2. Flash the system
Configuration/Setup error 3. SCSI device
  4. SCSI adapter card, if installed
  5. System board
  
030-03X-XXX
030-04X-XXX 1. SCSI signal cable
SCSI interface failure 2. Check power supply
  3. SCSI device
  4. SCSI adapter card, if installed
  5. System board
  
030-195-XXX 1. Information
SCSI interface Test aborted by user 2. Re-start the test, if need to
  
030-196-XXX 1. Depress F3 to review the logfile
SCSI interface test halt error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
030-197-XXX 1. Make sure component that is called out is
SCSI interface test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
030-198-XXX 1. If a component is called out, make sure it is
SCSI interface test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
030-199-XXX 1. Goto 'Undetermined Problem'
SCSI interface test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
035-000-XXX 1. No action
RAID interface Test Passed
035-0XX-XXX 1. RAID signal cable
RAID interface failure 2. RAID device
  3. RAID adapter card, if installed
  4. System board
  
035-195-XXX 1. Information
RAID interface Test aborted by user 2. Re-start the test, if need to
  
035-196-XXX 1. Depress F3 to review the logfile
RAID interface test halt error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
035-197-XXX 1. Make sure component that is called out is
RAID interface test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
035-198-XXX 1. If a component is called out, make sure it is
RAID interface test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
035-199-XXX 1. Goto 'Undetermined Problem'
RAID interface test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
071-000-XXX 1. No action
Audio port interface Test Passed
071-00X-XXX
071-01X-XXX
071-02X-XXX 1. Run Setup
Audio port error 2. Flash the system
  3. System board
  
071-03X-XXX 1. Speakers
Audio port failure 2. Microphone
  3. Audio card, if installed
  4. System board
  
071-04X-XXX 1. Run Setup
Audio port failure 2. Audio card, if installed
  3. System b*ard
  
071-195-XXX 1. Information
Audio port Test aborted by user 2. Re-start the test, if need to
  
071-196-XXX 1. Depress F3 to review the logfile
Audio port test halt error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
071-197-XXX 1. Make sure component that is called out is
Audio port test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
071-198-XXX 1. If a component is called out, make sure it is
RAID interface test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
071-199-XXX 1. Goto 'Undetermined Problem'
Audio port test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
071-25X-XXX 1. Speakers
Audio port failure 2. Audio card, if installed
  3. Aystem board
  
080-000-XXX 1. No action
Game port interface Test Passed
080-XXX-XXX 1. Remove the game port device and re-test the system
Game port interface error
080-195-XXX 1. Information
Game port interface Test aborted by user 2. Re-start the test, if need to
  
080-196-XXX 1. Depress F3 to review the logfile
Game port interface test halt error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
080-197-XXX 1. Make sure component that is called out is
Game port interface test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
080-198-XXX 1. If a component is called out, make sure it is
Game Port interface test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
080-199-XXX 1. Goto 'Undetermined Problem'
Game Port interface test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
086-000-XXX 1. No action
Mouse port interface Test Passed
086-001-XXX 1. Mouse
Mouse Port interface Presence 2. System board
  
086-032-XXX 1. Mouse
Mouse Port interface 2. System board
Device controller failure
086-035-XXX 1. Mouse
Mouse Port interface Reset 2. System board
  
086-040-XXX 1. Run Setup
Audio port interface IRQ failure 2. Mouse
  3. System board
  
086-195-XXX 1. Information
Mouse Port interface Test 2. Re-start the test, if need to
aborted by user
086-196-XXX 1. Depress F3 to review the logfile
Mouse Port interface test halt, error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
086-197-XXX 1. Make sure component that is called out is
Mouse Port interface test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
086-198-XXX 1. If a component is called out, make sure it is
Mouse Port interface test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
086-199-XXX 1. Goto 'Undetermined Problem'
Mouse Port interface test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
089-000-XXX 1. No action
Microprocessor Test Passed
089-XXX-XXX 1. Micrprocessor(s)
Microprocessor failure 2. System board
  
089-195-XXX 1. Information
Microprocessor test aborted by user 2. Re-start the test, if need to
  
089-196-XXX 1. Depress F3 to review the logfile
Microprocessor test halt error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
089-197-XXX 1. Make sure component that is called out is
Microprocessor test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
089-198-XXX 1. If a component is called out, make sure it is
Microprocessor test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
089-199-XXX 1. Goto 'Undetermined Problem'
Microprocessor test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
170-000-XXX 1. No action
Voltage Sensor(s) Test Passed
170-0XX-XXX 1. Flash system
Voltage Sensor(s) failure 2. System board
  
170-195-XXX 1. Information
Voltage Sensor(s) Test 2. Re-start the test, if need to
aborted by user
170-196-XXX 1. Depress F3 to review the logfile
Voltage Sensor(s) test halt, error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
170-197-XXX 1. Make sure component that is called out is
Voltage Sensor(s) test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
170-198-XXX 1. If a component is called out, make sure it is
Voltage Sensor(s) test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
170-199-XXX 1. Goto 'Undetermined Problem'
Voltage Sensor(s) test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
170-254-XXX 1. Voltage Regulator Module (VRM)
Voltage Sensor(s) Voltage 2. Microprocessor
Regulator Module error 3. System board
  
175-000-XXX 1. No action
Thermal Sensor(s) Test Passed
175-0XX-XXX 1. Flash system
Thermal Sensor(s) failure 2. System board
  
175-195-XXX 1. Information
Thermal Sensor(s) Test aborted by user 2. Re-start the test, if need to
  
175-196-XXX 1. Depress F3 to review the logfile
Thermal Sensor(s) test halt, error     See 'Viewing the Test Log'.
threshold exceeded. 2. Re-start the test to reset the logfile.
  
175-197-XXX 1. Make sure component that is called out is
Thermal Sensor(s) test warning     enabled and/or connected
  2. Re-run test
  3. Component that is called out in warning statement
  4. Component under test
  
175-198-XXX 1. If a component is called out, make sure it is
Thermal Sensor(s) test aborted     enabled and/or connected
  2. Flash the system and re-test
  3. Goto 'Undetermined Problem'
  
175-199-XXX 1. Goto 'Undetermined Problem'
Thermal Sensor(s) test failed, cause unknown 2. Flash the system and re-test
  3. Replace components under function test
  
175-250-XXX
175-251-XXX 1. Check fans
Thermal Sensor(s) limit error 2. Check Power supply
  3. Microprocessor
  4. System board
  
185-000-XXX 1. No action
Asset Security Test Passed
185-XXX-XXX 1. Assure Asset Security Enabled
Asset Security failure 2. Flash system
  3. System board
  
185-278-XXX 1. C2 Coverswitch
Asset Security Chassis Intrusion 2. System board
  
201-000-XXX 1. No action
System Memory Test Passed
201-XXX-XXX 1. Replace the memory called out by the test
System Memory error 2. System board
  
202-000-XXX 1. No action
System Cache Test Passed
202-XXX-XXX 1. Cache, if removable
System Cache error 2. System board
  3. Microprocessor
  
206-000-XXX 1. No action
Diskette Drive Test Passed
206-XXX-XXX 1. Diskette Drive Cable
Diskette Drive error 2. Check power supply voltages
  3. Diskette drive
  4. System board
  
215-000-XXX 1. No action
CD-ROM Drive Test Passed
215-XXX-XXX 1. CD-ROM Drive Cable
CD-ROM Drive error 2. Check power supply voltages
  3. CD-ROM drive
  4. System board
  
217-000-XXX 1. No action
Hard Disk Drive Test Passed
217-25X-XXX
217-26X-XXX 1. CD-ROM Drive Cable
Hard Disk Drive (IDE) error 2. Check power supply voltages
  3. Hard Disk drive (IDE)
  4. System board
  
217-28X-XXX
217-29X-XXX 1. CD-ROM Drive Cable
Hard Disk Drive (SCSI) error 2. Check power supply voltages
  3. Hard Disk drive (SCSI)
  4. SCSI adapter card
  5. System board
  
220-000-XXX 1. No action
Hi-Capacity Cartridge Drive Test Passed
220-XXX-XXX 1. Remove the Hi-Capacity Cartridge
Hi-Capacity Cartridge Drive error     Drive and re-test the system
  
301-000-XXX 1. No action
Keyboard Test Passed
301-XXX-XXX 1. Keyboard
Keyboard error 2. Check and test the Mouse
  3. System board
  
302-000-XXX 1. No action
Mouse Test Passed
302-XXX-XXX 1. Mouse
Keyboard error 2. Check and test the Keyboard
  3. System board
  
303-000-XXX 1. No action
Joystick Test Passed
303-XXX-XXX 1. Remove the Joystick and re-test the system
Joystick error
305-000-XXX 1. No action
Monitor DDC Test Passed
305-250-XXX 1. Run Setup to enable DDC
Monitor DDC selftest failure 2. Cable
  3. Monitor
  4. Video card
  5. System board
  
415-000-XXX 1. No action
Modem Test Passed
415-XXX-XXX 1. Remove the Modem and re-test the system
Modemerror


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.