  Diagnostic Error Codes (PC-Doctor)
In the following index, X can represent any number.
| Diagnostic Error Code | FRU/Action | 
|---|---|
| 000-000-XXX | 1. No action | 
| BIOS Test Passed | |
| 000-002-XXX | 1. Flash the system | 
| BIOS Timeout | 2. System board | 
| 000-024-XXX | 1. Flash the system | 
| BIOS Addressing failure | 2. System board | 
| 000-025-XXX | 1. Flash the system | 
| BIOS Checksum Value error | 2. Boot block | 
| 3. System board | |
| 000-026-XXX | 1. Flash the system | 
| Flash data error | 2. Boot block | 
| 3. System board | |
| 000-027-XXX | 1. Run Setup | 
| BIOS Configuration/Setup error | 2. Flash the system | 
| 3. Boot block | |
| 4. System board | |
| 000-034-XXX | 1. Reboot the system | 
| BIOS Buffer Allocation failure | 2. Flash the system | 
| 3. Run memory test | |
| 4. System board | |
| 000-035-XXX | 1. Flash the system | 
| BIOS Reset Condition detected | 2. System board | 
| 000-036-XXX | 1. Flash the system | 
| BIOS Register error | 2. Boot block | 
| 3. System board | |
| 000-038-XXX | 1. Flash the system | 
| BIOS Extension failure | 2. Adapter card | 
| 3. System board | |
| 000-039-XXX | 1. Flash the system | 
| BIOS DMI data error | 2. System board | 
| 000-195-XXX | 1. Information | 
| BIOS Test aborted by user | 2. Re-start the test, if need to | 
| 000-196-XXX | 1. Depress F3 to review the logfile | 
| BIOS test halt error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 000-197-XXX | 1. Make sure component that is called out is | 
| BIOS test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 000-198-XXX | 1. If a component is called out, make sure it is | 
| BIOS test warning | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 000-199-XXX | 1. Goto 'Undetermined Problem' | 
| BIOS test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 000-250-XXX | 1. Flash the system | 
| BIOS APM failure | 2. System board | 
| 000-270-XXX | 1. Flash the system | 
| BIOS ACP failure | 2. System board | 
| 001-000-XXX | 1. No action | 
| System Test Passed | |
| 001-00X-XXX | 1. System board | 
| System Error | |
| 001-01X-XXX | 1. System board | 
| System Error | |
| 001-024-XXX | 1. System board | 
| System Addressing test failure | |
| 001-025-XXX | 1. Flash the system | 
| System Checksum Value error | 2. System board | 
| 001-026-XXX | 1. Flash the system | 
| System FLASH data error | 2. System board | 
| 001-027-XXX | 1. Run Setup | 
| System Configuration/Setup error | 2. FLASH the system | 
| 3. System board | |
| 001-032-XXX | 1. System board | 
| System Device Controller failure | |
| 001-034-XXX | 1. Reboot the system | 
| System Device Buffer Allocation failure | 2. Flash the system | 
| 3. Run memory test | |
| 4. System board | |
| 001-035-XXX | 1. System board | 
| System Device Reset condition detected | |
| 001-036-XXX | 1. System board | 
| System Register error | |
| 001-038-XXX | 1. Adapter card | 
| System Extension failure | 2. System board | 
| 001-039-XXX | 1. Flash the system | 
| System DMIU data structure error | 2. System board | 
| 001-040-XXX | 1. Power-off/on system and re-test | 
| System IRQ failure | 2. System board | 
| 001-041-XXX | 1. Power-off/on system and re-test | 
| System DMA failure | 2. System board | 
| 001-195-XXX | 1. Information | 
| System Test aborted by user | 2. Re-start the test, if need to | 
| 001-196-XXX | 1. Depress F3 to review the logfile | 
| Systemtest halt, error threshold exceeded | See 'Viewing the Test Log' | 
| 2. Re-start the test to reset the logfile. | |
| 001-197-XXX | 1. Make sure components that is called out | 
| Systemtest warning | is enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 001-198-XXX | 1. If a component is called out, make sure | 
| Systemtest aborted | it is enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 001-199-XXX | 1. Goto 'Undetermined Problem' | 
| Systemtest failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace component under function test. | |
| 001-250-XXX | 1. System board | 
| System ECC error | |
| 001-254-XXX | |
| 001-255-XXX | |
| 001-256-XXX | |
| 001-257-XXX | 1. System board | 
| System DMA error | |
| 001-260-XXX | |
| 001-264-XXX | 1. System board | 
| System IRQ error | |
| 001-268-XXX | 1. device on IRQ 1 | 
| System IRQ 1 failure | 2. System board | 
| 001-269-XXX | 1. device on IRQ 2 | 
| System IRQ 2 failure | 2. System board | 
| 001-270-XXX | 1. device on IRQ 3 | 
| System IRQ 3 failure | 2. System board | 
| 001-271-XXX | 1. device on IRQ 4 | 
| System IRQ 4 failure | 2. System board | 
| 001-272-XXX | 1. device on IRQ 5 | 
| System IRQ 5 failure | 2. System board | 
| 001-273-XXX | 1. Diskette Cable | 
| System IRQ 6 (diskette drive) failure | 2. Diskette drive | 
| 3. System board | |
| 001-274-XXX | 1. device on IRQ 7 | 
| System IRQ 7 failure | 2. System board | 
| 001-275-XXX | 1. device on IRQ 8 | 
| System IRQ 8 failure | 2. System board | 
| 001-276-XXX | 1. device on IRQ 9 | 
| System IRQ 9 failure | 2. System board | 
| 001-277-XXX | 1. device on IRQ 10 | 
| System IRQ 10 failure | 2. System board | 
| 001-278-XXX | 1. device on IRQ 11 | 
| System IRQ 11 failure | 2. System board | 
| 001-279-XXX | 1. device on IRQ 12 | 
| System IRQ 12 failure | 2. System board | 
| 001-280-XXX | 1. device on IRQ 13 | 
| System IRQ 13 failure | 2. System board | 
| 001-281-XXX | 1. Harddisk drive Cable | 
| System IRQ 14 (harddisk drive) failure | 2. System board | 
| 3. Harddisk drive | |
| 4. System board | |
| 001-282-XXX | 1. device on IRQ 15 | 
| System IRQ 15 failure | 2. System board | 
| 001-286-XXX | |
| 001-287-XXX | |
| 001-288-XXX | 1. System board | 
| System Timer failure | |
| 001-292-XXX | 1. Run Setup and re-test | 
| System CMOS RAM error | 2. System board | 
| 001-293-XXX | 1. Battery | 
| System CMOS Battery | 2. System board | 
| 001-298-XXX | 1. Flash the system | 
| System RTC date/time update failure | 2. System board | 
| 001-299-XXX | 1. System board | 
| System RTC periodic interrupt failure | |
| 001-300-XXX | 1. System board | 
| System RTC Alarm failure | |
| 001-301-XXX | 1. Flash the system | 
| System RTC Century byte error | 2. System board | 
| 005-000-XXX | 1. No action | 
| Video Test Passed | |
| 005-00X-XXX | 1. Video card, if installed | 
| Video error | 2. System board | 
| 005-010-XXX | |
| 005-011-XXX | |
| 005-012-XXX | |
| 005-013-XXX | 1. Video card, if installed | 
| Video Signal failure | 2. System board | 
| 005-016-XXX | 1. Video RAM | 
| Video Simple Patterntest failure | 2. Video card, if installed | 
| 3. System board | |
| 005-024-XXX | 1. Video card, if installed | 
| Video Addressingtest failure | 2. System board | 
| 005-025-XXX | 1. Video card, if installed | 
| Video Checksum Value error | 2. System board | 
| 005-027-XXX | 1. Run Setup | 
| Video Configuration/Setup error | 2. Video drivers update | 
| 3. Video card, if installed | |
| 4. System board | |
| 005-031-XXX | 1. Video cable | 
| Video Device Cable failure | 2. Monitor | 
| 3. Video card, if installed | |
| 4. System board | |
| 005-032-XXX | 1. Video card, if installed | 
| Video Device Controller failure | 2. System board | 
| 005-036-XXX | 1. Video card, if installed | 
| Video Register error | 2. System board | 
| 005-038-XXX | 1. Video card, if installed | 
| System BIOS extension failure | 2. System board | 
| 005-040-XXX | 1. Video card, if installed | 
| Video IRQ failure | 2. System board | 
| 005-195-XXX | 1. Information | 
| Video Test aborted by user | 2. Re-start the test, if needed | 
| 005-196-XXX | 1. Depress F3 to review the logfile | 
| Videotest halt, error threshold exceeded | See 'Viewing the Test Log' | 
| 2. Re-start the test, to reset the logfile | |
| 005-197-XXX | 1. Make sure component that is called out | 
| Videotest warning | is enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 005-198-XXX | 1. If a component is called out, make sure | 
| Videotest aborted | it is enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 005-199-XXX | 1. Goto 'Undetermined Problem' | 
| Videotest failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under functiontest | |
| 005-2XX-XXX | |
| 005-3XX-XXX | 1. Videocard if installed | 
| Videosubsystem error | 2. System board | 
| 006-000-XXX | 1. No action | 
| Diskette interface Test Passed | |
| 006-0XX-XXX | 1. Diskette drive Cable | 
| Diskette interface error | 2. Diskette drive | 
| 3. System board | |
| 006-195-XXX | 1. Information | 
| Diskette interface test aborted by user | 2. Re-start the test, if need to | 
| 006-196-XXX | 1. Depress F3 to review the logfile | 
| Diskette interface test halt, | See 'Viewing the Test Log' | 
| error threshold exceeded | 2. Re-start the test to reset the logfile. | 
| 006-197-XXX | 1. Make sure component that is called out | 
| Diskette interface warning | is enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is calledout in warning statement | |
| 4. Component under test | |
| 006-198-XXX | 1. If a component is called out, make sure | 
| Diskette interface test aborted | it is enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 006-199-XXX | 1. Goto 'Undetermined Problem' | 
| Diskette interface test failed | 2. Flash the system and re-test | 
| cause unknown | 3. Replace component under function test | 
| 006-25X-XXX | 1. Diskettedrive Cable | 
| Diskette interface Error | 2. Diskette drive | 
| 3. System board | |
| 011-000-XXX | 1. No action | 
| Serialport Interface Test Passed | |
| 011-001-XXX | 1. Remove external serial device, if present | 
| Serialport Presence | 2. Run setup, enable port | 
| 3. System board | |
| 011-002-XXX | |
| 011-003-XXX | 1. System board | 
| Serialport Timeout/Parity error | |
| 011-013-XXX | |
| 011-014-XXX | 1. System board | 
| Serialport Control | |
| Signal/Loopback test failure | |
| 011-015-XXX | 1. Wrap plug | 
| Serialport External | 2. System board | 
| Loopback test failure | |
| 011-027-XXX | 1. Run Setup, enable port | 
| Serialport | 2. Flash the system | 
| Configuration/Setuperror | 3. System board | 
| 011-03X-XXX | |
| 011-04X-XXX | 1. System board | 
| Serialport failure | |
| 011-195-XXX | 1. Information | 
| Serialport Test aborted by user | |
| 2. Re-start the test, if need to | |
| 011-196-XXX | 1. Depress F3 to review the logfile | 
| Serial test halt, error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 011-197-XXX | 1. Make sure component that is called out is | 
| Serial port test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 011-198-XXX | 1. If a component is called out, make sure | 
| Serial port test aborted | it is enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 011-199-XXX | 1. Goto 'Undetermined Problem' | 
| Serial port test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace component under function test. | |
| 011-2XX-XXX | 1. External serial device | 
| Serial port signal failure | 2. System board | 
| 014-000-XXX | 1. No action | 
| Parallel port Interface Test Passed | |
| 014-001-XXX | 1. Remove external Parallel device, if present | 
| Parallel port Presence | 2. Run setup, enable port | 
| 3. System board | |
| 014-002-XXX | |
| 014-003-XXX | 1. System board | 
| Parallelport Timeout/Parity error | |
| 014-013-XXX | |
| 014-014-XXX | 1. System board | 
| Parallelport Control | |
| Signal/Loopback test failure | |
| 014-015-XXX | 1. Wrap plug | 
| Parallelport External | 2. System board | 
| Loopback test failure | |
| 014-027-XXX | 1. Run Setup, enable port | 
| Parallelport | 2. Flash the system | 
| Configuration/Setuperror | 3. System board | 
| 014-03X-XXX | |
| 014-04X-XXX | 1. System board | 
| Parallelport failure | |
| 014-195-XXX | 1. Information | 
| Parallelport Test aborted by user | |
| 2. Re-start the test, if need to | |
| 014-196-XXX | 1. Depress F3 to review the logfile | 
| Parallel port test halt, error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 014-197-XXX | 1. Make sure component that is called out is | 
| Parallel port test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 014-198-XXX | 1. If a component is called out, make sure | 
| Parallel port test aborted | it is enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 014-199-XXX | 1. Goto 'Undetermined Problem' | 
| Parallel port test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace component under function test. | |
| 014-2XX-XXX | |
| 014-3XX-XXX | 1. External parallel device | 
| Parallel port signal failure | 2. System board | 
| 015-000-XXX | 1. No action | 
| USB port Interface Test Passed | |
| 015-001-XXX | 1. Remove USB device(s) and re-test | 
| USB port Presence | 2. System board | 
| 015-002-XXX | 1. Remove USB device(s) and re-test | 
| USB port Timeout | 2. System board | 
| 015-015-XXX | 1. Remove USB Device(s) and re-test | 
| USB port External | 2. System board | 
| Loopback test failure | |
| 015-027-XXX | 1. Flash the system | 
| USB port Configuration/Setup error | 2. System board | 
| 015-032-XXX | 1. System board | 
| USB port Device Controller failure | |
| 015-034-XXX | 1. Reboot the system | 
| USB port buffer allocation failure | 2. Flash the system | 
| 3. Run memory test | |
| 4. System board | |
| 015-035-XXX | 1. Remove USB Device(s) and re-test | 
| USB port Reset condition detected | |
| 2. System board | |
| 015-036-XXX | 1. System board | 
| USB port Register error | |
| 015-040-XXX | 1. Run setup and check for conflicts | 
| USB port IRQ failure | enabled and/or connected | 
| 2. Flash the system | |
| 3. System board | |
| 015-195-XXX | 1. Information | 
| USB port Test aborted by user | 2. Re-start the test, if need to | 
| 015-196-XXX | 1. Depress F3 to review the logfile | 
| USB port test halt, error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 015-197-XXX | 1. Make sure component that is called out is | 
| USB port test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 015-198-XXX | 1. If a component is called out, make sure | 
| USB port test aborted | it is enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 015-199-XXX | 1. Goto 'Undetermined Problem' | 
| USB port test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 018-000-XXX | 1. No action | 
| PCI Card Test Passed | |
| 018-0XX-XXX | 1. PCI Card | 
| PCI Card Failure | 2. Riser card, if installed | 
| 3. System board | |
| 018-195-XXX | 1. Information | 
| PCI card Test aborted by user | 2. Re-start the test, if need to | 
| 018-196-XXX | 1. Depress F3 to review the logfile | 
| PCI Card test halt, error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 018-197-XXX | 1. Make sure component that is called out is | 
| PCI Card test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 018-198-XXX | 1. If a component is called out, make sure | 
| PCI Card test aborted | it is enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 018-199-XXX | 1. Goto 'Undetermined Problem' | 
| PCI Card test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 018-250-XXX | 1. PCI card | 
| PCI Card Service error | 2. Riser card, if installed | 
| 3. System board | |
| 020-000-XXX | 1. No action | 
| PCI Interface Test Passed | |
| 020-0XX-XXX | 1. PCI card | 
| PCI Interface error | 2. Riser card, if installed | 
| 3. System board | |
| 020-195-XXX | 1. Information | 
| PCI Test aborted by user | 2. Re-start the test, if need to | 
| 020-196-XXX | 1. Depress F3 to review the logfile | 
| PCI test halt, error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 020-197-XXX | 1. Make sure component that is called out is | 
| PCI test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 020-198-XXX | 1. If a component is called out, make sure | 
| PCI test aborted | it is enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 020-199-XXX | 1. Goto 'Undetermined Problem' | 
| PCI test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 020-262-XXX | 1. PCI card | 
| PCI system error | 2. Riser card, if installed | 
| 3. System board | |
| 025-000-XXX | 1. No action | 
| IDE interface Test Passed | |
| 025-00X-XXX | |
| 025-01X-XXX | 1. IDE signal cable | 
| IDE interface failure | 2. Check power supply | 
| 3. IDE device | |
| 4. System board | |
| 025-027-XXX | 1. IDE signal cable | 
| IDE interface | 2. Flash the system | 
| Configuration/Setup error | 3. IDE device | 
| 4. System board | |
| 025-02X-XXX | |
| 025-03X-XXX | |
| 025-04X-XXX | 1. IDE signal cable | 
| IDE interface failure | 2. Check power supply | 
| 3. IDE device | |
| 4. System board | |
| 025-195-XXX | 1. Information | 
| IDE interface Test aborted by user | 2. Re-start the test, if need to | 
| 025-196-XXX | 1. Depress F3 to review the logfile | 
| IDE interface test halt error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 025-197-XXX | 1. Make sure component that is called out is | 
| IDE interface test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 025-198-XXX | 1. If a component is called out, make sure it is | 
| IDE interface test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 025-199-XXX | 1. Goto 'Undetermined Problem' | 
| IDE interface test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 030-000-XXX | 1. No action | 
| SCSI interface Test Passed | |
| 030-00X-XXX | |
| 030-01X-XXX | 1. SCSI signal cable | 
| SCSI interface failure | 2. Check power supply | 
| 3. SCSI device | |
| 4. SCSI adapter card, if installed | |
| 5. System board | |
| 030-027-XXX | 1. SCSI signal cable | 
| SCSI interface | 2. Flash the system | 
| Configuration/Setup error | 3. SCSI device | 
| 4. SCSI adapter card, if installed | |
| 5. System board | |
| 030-03X-XXX | |
| 030-04X-XXX | 1. SCSI signal cable | 
| SCSI interface failure | 2. Check power supply | 
| 3. SCSI device | |
| 4. SCSI adapter card, if installed | |
| 5. System board | |
| 030-195-XXX | 1. Information | 
| SCSI interface Test aborted by user | 2. Re-start the test, if need to | 
| 030-196-XXX | 1. Depress F3 to review the logfile | 
| SCSI interface test halt error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 030-197-XXX | 1. Make sure component that is called out is | 
| SCSI interface test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 030-198-XXX | 1. If a component is called out, make sure it is | 
| SCSI interface test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 030-199-XXX | 1. Goto 'Undetermined Problem' | 
| SCSI interface test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 035-000-XXX | 1. No action | 
| RAID interface Test Passed | |
| 035-0XX-XXX | 1. RAID signal cable | 
| RAID interface failure | 2. RAID device | 
| 3. RAID adapter card, if installed | |
| 4. System board | |
| 035-195-XXX | 1. Information | 
| RAID interface Test aborted by user | 2. Re-start the test, if need to | 
| 035-196-XXX | 1. Depress F3 to review the logfile | 
| RAID interface test halt error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 035-197-XXX | 1. Make sure component that is called out is | 
| RAID interface test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 035-198-XXX | 1. If a component is called out, make sure it is | 
| RAID interface test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 035-199-XXX | 1. Goto 'Undetermined Problem' | 
| RAID interface test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 071-000-XXX | 1. No action | 
| Audio port interface Test Passed | |
| 071-00X-XXX | |
| 071-01X-XXX | |
| 071-02X-XXX | 1. Run Setup | 
| Audio port error | 2. Flash the system | 
| 3. System board | |
| 071-03X-XXX | 1. Speakers | 
| Audio port failure | 2. Microphone | 
| 3. Audio card, if installed | |
| 4. System board | |
| 071-04X-XXX | 1. Run Setup | 
| Audio port failure | 2. Audio card, if installed | 
| 3. System b*ard | |
| 071-195-XXX | 1. Information | 
| Audio port Test aborted by user | 2. Re-start the test, if need to | 
| 071-196-XXX | 1. Depress F3 to review the logfile | 
| Audio port test halt error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 071-197-XXX | 1. Make sure component that is called out is | 
| Audio port test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 071-198-XXX | 1. If a component is called out, make sure it is | 
| RAID interface test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 071-199-XXX | 1. Goto 'Undetermined Problem' | 
| Audio port test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 071-25X-XXX | 1. Speakers | 
| Audio port failure | 2. Audio card, if installed | 
| 3. Aystem board | |
| 080-000-XXX | 1. No action | 
| Game port interface Test Passed | |
| 080-XXX-XXX | 1. Remove the game port device and re-test the system | 
| Game port interface error | |
| 080-195-XXX | 1. Information | 
| Game port interface Test aborted by user | 2. Re-start the test, if need to | 
| 080-196-XXX | 1. Depress F3 to review the logfile | 
| Game port interface test halt error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 080-197-XXX | 1. Make sure component that is called out is | 
| Game port interface test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 080-198-XXX | 1. If a component is called out, make sure it is | 
| Game Port interface test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 080-199-XXX | 1. Goto 'Undetermined Problem' | 
| Game Port interface test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 086-000-XXX | 1. No action | 
| Mouse port interface Test Passed | |
| 086-001-XXX | 1. Mouse | 
| Mouse Port interface Presence | 2. System board | 
| 086-032-XXX | 1. Mouse | 
| Mouse Port interface | 2. System board | 
| Device controller failure | |
| 086-035-XXX | 1. Mouse | 
| Mouse Port interface Reset | 2. System board | 
| 086-040-XXX | 1. Run Setup | 
| Audio port interface IRQ failure | 2. Mouse | 
| 3. System board | |
| 086-195-XXX | 1. Information | 
| Mouse Port interface Test | 2. Re-start the test, if need to | 
| aborted by user | |
| 086-196-XXX | 1. Depress F3 to review the logfile | 
| Mouse Port interface test halt, error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 086-197-XXX | 1. Make sure component that is called out is | 
| Mouse Port interface test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 086-198-XXX | 1. If a component is called out, make sure it is | 
| Mouse Port interface test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 086-199-XXX | 1. Goto 'Undetermined Problem' | 
| Mouse Port interface test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 089-000-XXX | 1. No action | 
| Microprocessor Test Passed | |
| 089-XXX-XXX | 1. Micrprocessor(s) | 
| Microprocessor failure | 2. System board | 
| 089-195-XXX | 1. Information | 
| Microprocessor test aborted by user | 2. Re-start the test, if need to | 
| 089-196-XXX | 1. Depress F3 to review the logfile | 
| Microprocessor test halt error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 089-197-XXX | 1. Make sure component that is called out is | 
| Microprocessor test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 089-198-XXX | 1. If a component is called out, make sure it is | 
| Microprocessor test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 089-199-XXX | 1. Goto 'Undetermined Problem' | 
| Microprocessor test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 170-000-XXX | 1. No action | 
| Voltage Sensor(s) Test Passed | |
| 170-0XX-XXX | 1. Flash system | 
| Voltage Sensor(s) failure | 2. System board | 
| 170-195-XXX | 1. Information | 
| Voltage Sensor(s) Test | 2. Re-start the test, if need to | 
| aborted by user | |
| 170-196-XXX | 1. Depress F3 to review the logfile | 
| Voltage Sensor(s) test halt, error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 170-197-XXX | 1. Make sure component that is called out is | 
| Voltage Sensor(s) test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 170-198-XXX | 1. If a component is called out, make sure it is | 
| Voltage Sensor(s) test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 170-199-XXX | 1. Goto 'Undetermined Problem' | 
| Voltage Sensor(s) test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 170-254-XXX | 1. Voltage Regulator Module (VRM) | 
| Voltage Sensor(s) Voltage | 2. Microprocessor | 
| Regulator Module error | 3. System board | 
| 175-000-XXX | 1. No action | 
| Thermal Sensor(s) Test Passed | |
| 175-0XX-XXX | 1. Flash system | 
| Thermal Sensor(s) failure | 2. System board | 
| 175-195-XXX | 1. Information | 
| Thermal Sensor(s) Test aborted by user | 2. Re-start the test, if need to | 
| 175-196-XXX | 1. Depress F3 to review the logfile | 
| Thermal Sensor(s) test halt, error | See 'Viewing the Test Log'. | 
| threshold exceeded. | 2. Re-start the test to reset the logfile. | 
| 175-197-XXX | 1. Make sure component that is called out is | 
| Thermal Sensor(s) test warning | enabled and/or connected | 
| 2. Re-run test | |
| 3. Component that is called out in warning statement | |
| 4. Component under test | |
| 175-198-XXX | 1. If a component is called out, make sure it is | 
| Thermal Sensor(s) test aborted | enabled and/or connected | 
| 2. Flash the system and re-test | |
| 3. Goto 'Undetermined Problem' | |
| 175-199-XXX | 1. Goto 'Undetermined Problem' | 
| Thermal Sensor(s) test failed, cause unknown | 2. Flash the system and re-test | 
| 3. Replace components under function test | |
| 175-250-XXX | |
| 175-251-XXX | 1. Check fans | 
| Thermal Sensor(s) limit error | 2. Check Power supply | 
| 3. Microprocessor | |
| 4. System board | |
| 185-000-XXX | 1. No action | 
| Asset Security Test Passed | |
| 185-XXX-XXX | 1. Assure Asset Security Enabled | 
| Asset Security failure | 2. Flash system | 
| 3. System board | |
| 185-278-XXX | 1. C2 Coverswitch | 
| Asset Security Chassis Intrusion | 2. System board | 
| 201-000-XXX | 1. No action | 
| System Memory Test Passed | |
| 201-XXX-XXX | 1. Replace the memory called out by the test | 
| System Memory error | 2. System board | 
| 202-000-XXX | 1. No action | 
| System Cache Test Passed | |
| 202-XXX-XXX | 1. Cache, if removable | 
| System Cache error | 2. System board | 
| 3. Microprocessor | |
| 206-000-XXX | 1. No action | 
| Diskette Drive Test Passed | |
| 206-XXX-XXX | 1. Diskette Drive Cable | 
| Diskette Drive error | 2. Check power supply voltages | 
| 3. Diskette drive | |
| 4. System board | |
| 215-000-XXX | 1. No action | 
| CD-ROM Drive Test Passed | |
| 215-XXX-XXX | 1. CD-ROM Drive Cable | 
| CD-ROM Drive error | 2. Check power supply voltages | 
| 3. CD-ROM drive | |
| 4. System board | |
| 217-000-XXX | 1. No action | 
| Hard Disk Drive Test Passed | |
| 217-25X-XXX | |
| 217-26X-XXX | 1. CD-ROM Drive Cable | 
| Hard Disk Drive (IDE) error | 2. Check power supply voltages | 
| 3. Hard Disk drive (IDE) | |
| 4. System board | |
| 217-28X-XXX | |
| 217-29X-XXX | 1. CD-ROM Drive Cable | 
| Hard Disk Drive (SCSI) error | 2. Check power supply voltages | 
| 3. Hard Disk drive (SCSI) | |
| 4. SCSI adapter card | |
| 5. System board | |
| 220-000-XXX | 1. No action | 
| Hi-Capacity Cartridge Drive Test Passed | |
| 220-XXX-XXX | 1. Remove the Hi-Capacity Cartridge | 
| Hi-Capacity Cartridge Drive error | Drive and re-test the system | 
| 301-000-XXX | 1. No action | 
| Keyboard Test Passed | |
| 301-XXX-XXX | 1. Keyboard | 
| Keyboard error | 2. Check and test the Mouse | 
| 3. System board | |
| 302-000-XXX | 1. No action | 
| Mouse Test Passed | |
| 302-XXX-XXX | 1. Mouse | 
| Keyboard error | 2. Check and test the Keyboard | 
| 3. System board | |
| 303-000-XXX | 1. No action | 
| Joystick Test Passed | |
| 303-XXX-XXX | 1. Remove the Joystick and re-test the system | 
| Joystick error | |
| 305-000-XXX | 1. No action | 
| Monitor DDC Test Passed | |
| 305-250-XXX | 1. Run Setup to enable DDC | 
| Monitor DDC selftest failure | 2. Cable | 
| 3. Monitor | |
| 4. Video card | |
| 5. System board | |
| 415-000-XXX | 1. No action | 
| Modem Test Passed | |
| 415-XXX-XXX | 1. Remove the Modem and re-test the system | 
| Modemerror | 
Please see the LEGAL  -  Trademark notice.
Feel free - send a 
  for any BUG on this page found - Thank you.