| AHA-2940/2940W at Bus:Device xx:xxh |
| |
|Configuration |
| |
|SCSI Channel Interface Definitions |
| Host Adapter SCSI ID .............. 7 |
| SCSI Parity Checking .............. Enabled |
| Host Adapter SCSI Termination ..... Enabled |
|Additional Options |
| SCSI Device Configuration ......... press <Enter> |
| Advanced configuration Options .... press <Enter> |
| |
| <F6> - Reset to Host Adapter Defaults |
| |
|Arrow keys to move cursor, <Enter> to select option, |
|<Esc> to exit (*=default) |
+-------------------------------------------------//--+
Host Adapter SCSI ID
changes the host adapter SCSI ID from its default value of 7.
+-------------------------------------------------//--+
| AHA-2940/2940W at Bus:Device xx:xxh |
| |
| 0 |
| 1 |
| 2 |
| 3 |
| 4 |
| 5 |
| 6 |
| * 7 |
| |
|Arrow keys to move cursor, <Enter> to select option, |
|<Esc> to exit (*=default) |
+-------------------------------------------------//--+
NOTE: The menu for the AHA-2940W adapter displays SCSI IDs #0 to #15
SCSI Parity Checking
Enables or disables host adapter SCSI parity checking.
+-------------------------------------------------//--+
| AHA-2940/2940W at Bus:Device xx:xxh |
| |
| * Enabled |
| Disabled |
| |
|Arrow keys to move cursor, <Enter> to select option, |
|<Esc> to exit (*=default) |
+-------------------------------------------------//--+
Host Adapter SCSI Termination
Configures host adapter SCSI termination.
The following menu is displayed if an AHA-2940 adapter is installed.
+-------------------------------------------------//--+
| AHA-2940/2940W at Bus:Device xx:xxh |
| |
| * Enabled |
| Disabled |
| |
|Both ends of the SCSI bus should be terminated. Host |
|Adapter termination should be disabled if you attach |
|SCSI devices to both internal and external connectors|
|since the host adapter would then be in the middle |
|of the SCSI bus. |
| |
| Device Connection | Termination |
| ------------------------------|------------ |
| Internal devices only | Enabled |
| External devices only | Enabled |
| Internal and External devices | Disabled |
| |
|Arrow keys to move cursor, <Enter> to select option, |
|<Esc> to exit (*=default) |
+-------------------------------------------------//--+
The following menu is displayed if an AHA-2940W adapter is installed:
+-------------------------------------------------//--+
| AHA-2940/2940W at Bus:Device xx:xxh |
| |
| * Low ON / High ON |
| Low OFF / High OFF |
| Low OFF / High ON |
| |
|Both ends of the SCSI bus should be terminated. Host |
|Adapter termination should be disabled if you attach |
|SCSI devices to both internal and external connectors|
|since the host adapter would then be in the middle |
|of the SCSI bus. |
| |
| Device Connection | Termination |
| ------------------------------|------------ |
| Internal devices only | Enabled |
| External devices only | Enabled |
| Internal and External devices | Disabled |
| |
|Arrow keys to move cursor, <Enter> to select option, |
|<Esc> to exit (*=default) |
+-------------------------------------------------//--+
SCSI Device Configuration
allows you to configure certain parameters of each SCSI device on the SCSI bus.
If selected, the following information for each SCSI ID is displayed even if some SCSI IDs are
not assigned to a device:
+-------------------------------------------------//----------------------------+
| |
| SCSI Device Configuration |
| |
|SCSI Device ID #0 #1 #2 #3 #4 #5 #6 #7 |
|---------------------------------------------------------------------------- |
|Initiate Sync Negotiation yes yes yes yes yes yes yes yes |
|Maximum Sync Transfer Rate 10.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0 |
|Enable Disconnection yes yes yes yes yes yes yes yes |
|------ Options listed Below Have NO EFFECT if BIOS is Disabled ------------- |
|Send Start Unit Command no no no no no no no no |
|Include in BIOS Scan yes yes yes yes yes yes yes yes |
| |
|Arrow keys to move cursor, <Enter> to select option, <Esc> to exit (*=default) |
+-------------------------------------------------//----------------------------+
NOTE: The menu for the AHA-2940W adapter displays SCSI IDs #0 to #15
SCSISelect AHA-2940 AHA-2940W
Transfer Rate Effective Transfer Effective Transfer
Rate Rate
-----------------------------------------------------------
10.0 10 MB per second 20 MB per second
8.0 8 MB per second 16 MB per second
6.7 6.7 MB per second 13.4 MB per second
5.0 5.0 MB per second 10.0 MB per second
NOTE:
+-------------------------------------------------//----------------------------+
| |
| Advanced Configuration Options |
| |
| Reset Bus at Host Adapter Initialization ........................ Enabled |
| |
|-------Options Listed Below Have NO EFFECT if the BIOS is Disabled ----------- |
| |
| Host Adapter BIOS (Configuration Utility Reserves BIOS) ......... Enabled |
| Support Removable Disk Under BIOS as Fixed Disks ................ Enabled |
| Extended BIOS Translation for DOS Drivers > 1 GByte ............. Enabled |
| BIOS Support for More Than 2 Drives (MS-DOS (R) 5.0 and above) .. Enabled |
| |
|Arrow keys to move cursor, <Enter> to select option, <Esc> to exit (*=default) |
+-------------------------------------------------//----------------------------+
NOTE: Do not change these file options unless absolutely necessary.
+-------------------------------------------------//--+
| AHA-2940/2940W at Bus:Device xx:xxh |
| |
| Select SCSIDisk and press <Enter> |
| |
| SCSI ID# 1 : Quantum P140S 940-40-94xx |
| SCSI ID# 2 : No Device |
| SCSI ID# 3 : SyQuest SQ 5110 |
| SCSI ID# 4 : No Device |
| SCSI ID# 5 : No Device |
| SCSI ID# 6 : No Device |
| SCSI ID# 7 : AHA-2940/2940W |
| |
|Arrow keys to move cursor, <Enter> to select option, |
|<Esc> to exit (*=default) |
+-------------------------------------------------//--+
NOTE: The menu for the AHA-2940W adapter displays SCSI IDs #0 to #15
When you select SCSI Disk Utilities from the Options menu, the SCSISelect utility scans the SCSI bus and lists
all SCSI devices installed on the SCSI bus. When you highlight a device by moving to it with the cursor keys and pressing Enter, a small window appears. You
can select Format Disk or Verify Media from this menu.
Format Disk : performs a low-level format on disk devices.
NOTE: A low-level format destroys all data on the drive. Be sure to back up all data before performing this operation. You cannot abort a low-level format once it is started.
Most SCSI disk devices are pre-formatted and do not need to be fornatted again. The Adaptec Format Disk utility is compatible with most
SCSI disk drives. Run it on hard disk drives or removable-media drives that where previouly used with non-Adaptec host adapters.
Verify Disk Media : scans the selected device's media for defects.
NOTE: Press Esc at any time to abort the Verify Disk Media utility.
If this utility finds bad blocks, it prompts you to reassign them. If you select yes, the blocks will no longer be used.