Problems Detected During Installation
Problems Detected During Installation
If the system will not boot from the standard hard disk drive or a boot program on the diskette drive (after the
initial hardware installation). check the following:
- If the AHA-2940/2940W LED and the SCSI drive LED are always on, the SCSI cables might be installed in a reverse
position between the host adapter and the drive.
- If the AHA-2940/2940W BIOS message is not displayed on the screenduring system boot, the system does not recognice
the host adapter BIOS. Be sure that host adapter BIOS is enabled.
- Be sure there are no address conflicts betweena PCI device and an EISA or ISA device.
- If you see the message Host adapter not found , the host adapter has detected an internal failure. Be sure
the host adapter is firmly seated in the PCI slot.
- If you see the message Host adapter found but not configured , run the SCSISelect utility to
configure the host adapter. See 'SCSISelect Configuration Utility'
More INFORMATION / HELP is available at the IBM-HelpCenter
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.