| 
    | 
 
 Setting                        Default Value
 -------------------------------------------------
 Host Adapter SCSI ID           7
 -------------------------------------------------
 SCSI Parity Checking           Enabled
 -------------------------------------------------
 Host Adapter SCSI Termination  Enabled
 AHA-2940/2940W                 Low On / High On
 -------------------------------------------------
 Reset SCSI Bus at Host         Enabled
 Adapter initialization
 -------------------------------------------------
 Host Adapter BIOS              Enabled
 -------------------------------------------------
 Support Removable Disks        Boot only
 Under Bios as Fixed Disks 1
 -------------------------------------------------
 Extended BIOS Translation      Enabled
 for DOS, 1GB 1
 -------------------------------------------------
 BIOS Support for More Than     Enabled
 2 Drives 1
 -------------------------------------------------
  1 Settings valid only if the
    adapter BIOS is enabled.
Individual Settings
The following settings are for each SCSI device connected to the adapter:
 Setting                        Default Value
 -------------------------------------------------
 Initiate Sync Negotiation      Yes
 -------------------------------------------------
 Maximum Sync Transfer Rate     10MB per second 2
 -------------------------------------------------
 Enable Disconnection           Yes
 -------------------------------------------------
 Send Start Unit SCSI           No
 Command 1
 -------------------------------------------------
 Include in BIOS Scan 1         Yes
 -------------------------------------------------
 Initiate Wide Negotiations 3   Enabled
 -------------------------------------------------
  1 Settings are invalid only if the adapter
    BIOS is enabled.
  2 20MB per second max. synchr. transfer on
    AHA-2940W.
  3 AHA-2940W adapters only.
Please see the LEGAL  -  Trademark notice.
Feel free - send a 
  for any BUG on this page found - Thank you.