Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Halt Indications (HALT)



Halt Indications (HALT)

If during the early POST code, a fatal error is detected, the system will display a halting  message with a corresponding error code to indicate the reason for the halt condition. The message will be displayed on the information panel in the following format:

HALT:XXXxxx

Where XXX is the following code number, replace the FRU(s) in the order listed. If present, ignore the last three digits(xxx).

NOTE: The exceptions to the above three or six digit error code format are the following error codes.

Halt Code    FRU
02 1. System Board
COM 1 failure 2. Bridge Card
  
101 1. System Board
COM 1 failure 2. Bridge Card
  3. Default Processor Card
  
102 1. Memory Card
Memory failure 2. System Board
  3. Default Processor Card
  
103 1. Bridge Card
Bridge failure 2. Default Processor Card
  3. System Board
  
104 1. Any Processor Card
Processor Card failure. 2. System Board
See 'Undetermined Failing Processor Diagnostics' 3. Bridge Card
  
105 1. Memory Card
Memory failure 2. System Board
  3. Default Processor Card
  
106 1. Processor Card
Unknown POST path. 2. System Board.
NOTE: This is a software
error and the system should
be re-flashed with the latest
level of the POST code. If
the error persists, a faulty
processor card may be the
cause.
107 1. Bridge Card
Unexpected interrupt or trap 2. System Board.
See 'Undetermined Failing Processor Diagnostics' 3. Any Processor Card
  4. Memory Card
  
107C 1. Processor Card
NMI error 2. Bridge Card
  3. Any remaining Processor Cards
  4. System Board
  
108 1. Memory Card
Not enough memory found 2. Default Processor Card
  3. System Board
  
109 1. Memory Card
Memory error 2. System Board
  3. Default Processor Card
  
1FF 1. Memory Card
Miscellaneous fatal error. 2. Any Processor Card
See 'Undetermined Failing Processor Diagnostics' 3. Bridge Card
  4. System Board


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.