|
RAID Adapter Message | Action |
---|---|
n logical drives are installed | n represents the number of defined logical |
drives. | |
This is an information message. No action is required. | |
Controller is not responding to | The ServeRAID adapter is not operational. |
commands. No logical drives are | Make sure that the adapter is fully seated. If the |
installed. | problem persists, have the system serviced. |
Error : Cannot disable this | The adapter was unable to prevent an extra copy |
adapter BIOS. | of the adapter BIOS from being stored on the server. |
This condition occurs when the server contains multiple | |
ServeRAID adapters. | |
When the prompt to disable extra copies on the adapter | |
BIOS appears, type N (No) | |
Following drives not responding, | One or more drives did not respond to the adapter. |
(old state: new state ch: bay) | For example, the adapterdetect a new drive in an |
unconfigured bay, and the drive is not part of the | |
current configuration. This might also occur if the | |
adapter detect that a configured drive is missing. | |
Select F5 to accept the new state that the | |
ServeRAID adapter will assign to the drive. For example, | |
the adapter will assign the drive a state of defunct | |
or empty. | |
Following new drives found | One or more drives were found in an unconfigured bay. |
(old state: new state ch: bay) | For each drive listed, a new state of Ready (RDY) |
appears. This is an information message. No action | |
is required. | |
Following drives found in new | POST found that the location of one or more drives |
location (old ch: old bay > | does not match the stored configuration information. |
new ch: new bay) | (See 'Configured Drives Are Not in the Configured Location') |
for more information. | |
Installation stopped | The server cannot access the ServeRAID adapter. |
This is a follow-on message to a preceding message. | |
Follow the 'Action' instructions for the preceding | |
message to resolve the problem. | |
Recoverable configuration error, | The configuration data stored on the adapter NVRAM does |
run Configuration program. | not match the configuration data stored in the adapter |
EEPROM. | |
Insert the IBM RAID Adapter Option Diskette, then press | |
Ctrl+Alt+Del to restart the system. | |
Select Advanced Functions and synchronize the | |
adapter configuration. See 'Resetting the Adapter Configuration' | |
for more information. | |
ServeRAID firmware version xx.yy | This is the version level of the ServeRAID adapter's firmware. |
This is an information message. No action is required. | |
WARNING: n logical drives | One or more drives have failed. |
are critical, n logical drives | Replace the defunct drives as soon as possible to |
offline. | prevent data loss. |
The server has an error due to a | One or more logical drives are in a blocked state. |
Blocked Logical Drive. | Press F4 to unblock the logical drive, or press |
F5 to continue without any changes. |
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.