Code/Description | FRU/Action |
---|---|
00 | 1. See the system error log and follow the instruction for the error in the log. |
(POST failed) | |
01 | 1. See the system error log and follow the instruction for the error in the log. |
(POST warning) | |
08 | 1. See the system error log and follow the instruction for the error in the log. |
(Application failed) | |
09 | 1. See the system error log and follow the instruction for the error in the log. |
(Application warning) | |
10 | 1. Try to reboot the system. |
(Boot failed) | 2. See system error log for other possible errors. |
18 | 1. Restart the server. |
(Operating system failed) | |
20 | 1. Clean out the error log. |
(Log full) | |
80 | 1. Ensure that all four fans are working. |
(Over temperature) | 2. Ensure the air intakes are clear. |
3. Ensure the room temperature is not to hot (See User's Handbook). | |
4. Replace the following FRU for the temperature failure indicated in the error log: | |
° Ambient temperature, Front Panel | |
° Hard disk drive temperature, SCSI Backplane | |
° Processor temperature, Processor | |
85 | 1. See system error log to determine if there are any power supply or VRM errors. |
(Over voltage) | 2. Power Control Card |
3. Processor Board | |
86 | 1. See system error log to determine if there are any power supply or VRM errors. |
(Low voltage) | 2. Power Control Card |
3. Processor Board | |
90 | 1. Power Supply x |
(Power x) | 2. Power Control Card |
98 | 1. See system error log to determine if there are any power supply or VRM errors. |
(Power system) | 2. Power Control Card |
A0 | 1. Fan X |
(Fan x, see | 2. Fan Cable |
('Error Symptoms') | 3. Power Control Card |
B0 | 1. Ensure the covers are attached correctly. |
(Intrusion) | 2. Verify that there has been an intrusion into the system. |
3. Intrusion Cable | |
4. Front Panel | |
B8 | 1. Check the cable connection to the front panel. |
(Display) | 2. Front Panel Table |
C0 | 1. See the system error log and follow the instruction for the error in the log. |
(SMI error) | 2. Replace the FRU for the following problems listed. |
° PCI related error: | |
a. Adapter | |
b. I/O Board | |
° Processor related error: | |
a. Processor | |
b. Processor Board | |
° Memory related error: | |
a. DIMM | |
b. Memory Board | |
c. Processor Board | |
C0 | 1. See system error log to determine which DIMM failed on which card. |
(Memory) |