Error Symptom | FRU/Action |
---|---|
CD is not working properly. | 1. Clean the CD |
2. Clean the optical-head lens. | |
3. CD-ROM Drive | |
CD-ROM drive tray is not working. | 1. Insert the end of a paper clip into the manual tray-release |
(The server must be powered-on.) | opening. |
If the server is on and the tray | 2. CD-ROM Drive |
does not eject, | |
CD-ROM drive is not recognized. | 1. Run Configuration/Setup, enabled primary IDE channel. |
2. Check cables and jumpers. | |
3. Check for correct device driver. | |
Diskette drive in-use light | 1. The diskette drive is enabled in the configuration programs. |
stays on, or the system | 2. The diskette is good and not damaged. |
bypasses the diskette drive. | (Try another diskette if you have one.) |
If there is a diskette in the drive, verify that: | |
3. The diskette is inserted correctly in the drive. | |
4. The diskette contains the necessary files to start the server. | |
5. The software program is OK. | |
If the diskette drive in-use light stays on, or the system | |
continues to bypass the diskette drive, replace the diskette drive. | |
Fan (one only) not running. | 1. Swap fans to see if the fan is defective. |
2. Power Control Card | |
3. Fan Cable | |
Fans (two only) not running. | 1. Check the connection between the fan cables and the power backplane. |
2. Fans | |
3. Power Control Card | |
4. Power Backplane | |
Fans (all) not running. | 1. Check fan cables |
2. Power Control Card | |
3. Power Backplane | |
Fans (all) continuously run fast. | 1. Power Control Card |
2. Front Panel Card | |
3. System Management Card | |
Monitor problems (general) | 1. Monitor |
Some IBM monitors have | 2. Display Adapter/I/O Function Card |
their own self-tests. If you | 3. I/O Board |
suspect a problem with the | |
monitor, refer to the | |
information that comes with | |
the monitor for adjusting | |
and testing instructions. |