Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

I/O Board Removal (Netfinity 7000-M10 - Type 8680)



I/O Board Removal

Before you begin: Read 'Safety Information'


Note: Be sure to update the BIOS to the latest level when replacing this FRU.

 

To Remove the I/O board, do the following:
  1.  Power-off the system.
  2.  Disconnect all power to the system.
  3.  Remove the top cover, see 'Removing the Top Cover'.
  4.  Disconnect all I/O board cables.
  5.  Disconnect all cables attached to adapters installed on the I/O board, then, remove the adapters.
  6.  Remove the shuttle assembly, see 'Shuttle Assembly Removal'.
  7.  Remove the twelve I/O board screws -1-.
  8.  Remove the I/O board clip 2 and lift the I/O board out of the server.