Power Supply LEDs: The AC Power LEDs, located on the rear of the
power supply, provide status information about the power supply.
See 'Front Panel Indicators' for the location of these LEDs.
The following table describes the AC Power LEDs.
| AC Power LED | Description and Action |
|---|---|
| On | The power supply is on and operating correctly. |
| Off | There is an AC power problem. Possible causes: 1. There is no AC power to the power supply. Actions: Verify that: ° The power cord is properly connected to the server. ° The power outlet functions properly. 2. The power supply has failed. Action: Replace the power supply. |
| No beep, fans running, and AC power LED blinking |
System held in reset Possible causes: 1. If an optional VRM is installed and no optional processor. Action: Remove the optional VRM. 2. If optional VRM failed. Action: Replace the optional VRM. 3. If primary VRM failed. Action: Replace the system board. 4. If system board failed. Action: Replace system board. |