Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

Error Codes (Adaptec)



  Error Codes Adaptec

Error Message    FRU/Action
  
0h 1. None
No Sense
1h 1. Device
Recovery Error 2. Cable
  3. Adapter
  4. System Board
  
2h 1. Device
Not Ready 2. Cable
  3. Adapter
  4. System Board
  
3h 1. Device
Medium Error 2. Cable
  3. Adapter
  4. System Board
  
4h 1. Device
Medium Error 2. Cable
  3. Adapter
  4. System Board
  
5h 1. Adapter
Illegal Request 2. Cable
  3. Device
  4. System Board
  
6h 1. Device
Unit Attention 2. Adapter
  3. Cable
  4. System Board
  
7h 1. Device
DATA Protect 2. Adapter
  3. Cable
  4. System Board
  
8h 1. Device
Blank Check 2. Adapter
  3. Cable
  4. System Board
  
9h 1. None
Vendor Specific
Ah 1. Device
Copy Aborted 2. Cable
  3. Adapter
  4. System Board
  
Bh 1. Device
Aborted Command 2. Adapter
  3. Cable
  4. System Board
  
Ch 1. None
Equal
Dh 1. Device
Volume Overflow 2. Adapter
  3. System Board
  4. Cable
  
Eh 1. Device
Miscompare 2. Adapter
  3. System Board
  4. Cable


See Symptom-to-FRU Index (Adaptec)


More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.