The adapter configuration Flash Utility menu is displayed:
Flash Utility
Select one:
Configure Service Processor
View Service Processor Configuration
Update Service Processor
Set Up COM Ports
Configure OS Watchdog Timer
Exit
Enter F1=Help F3=Exit
-------------------------------------------------------------------------
CR1 Dot On CR1 Dot Off
-------------------------------------------------------------------------
Problem indication, Check | Normal, Check CR2 Dot.
34-pin interface cable connection |
Replace: |
Cable then, Adapter. |
Note: For Advanced Systems Mgmt. External Power
Control Units, replace the 10-pin External Power Source Cable, then
External Power Control Unit
-------------------------------------------------------------------------
CR2 Dot Blinking CR2 Dot Off
-------------------------------------------------------------------------
Normal, microcode is loaded. | Microcode is not loaded.
Go to step 6 | Select Update Service Processor
| on the Flash Utility Menu and
| follow the prompts. Then return
| to step 5. If CR2 continues to be
| off, replace the adapter battery.
Note: If you reset the adapter by following the procedure
'Resetting the Adapter and Clearing the Configuration', CR2 Dot will be off
and you must select Update Service Processor on the Flash Utility
menu.