The adapter configuration Flash Utility menu is displayed:
                  Flash Utility
     Select one:
     Configure Service Processor
     View Service Processor Configuration
     Update Service Processor
     Set Up COM Ports
     Configure OS Watchdog Timer
     Exit
      Enter     F1=Help     F3=Exit
 
  -------------------------------------------------------------------------
   CR1 Dot On                           CR1 Dot Off
  -------------------------------------------------------------------------
   Problem indication, Check         |  Normal, Check CR2 Dot.
   34-pin interface cable connection |
   Replace:                    |
   Cable then, Adapter.              |
   Note: For Advanced Systems Mgmt. External Power
   Control Units, replace the 10-pin External Power Source Cable, then
   External Power Control Unit
  -------------------------------------------------------------------------
   CR2 Dot Blinking                     CR2 Dot Off
  -------------------------------------------------------------------------
   Normal, microcode is loaded.      |  Microcode is not loaded.
   Go to step 6                      |  Select Update Service Processor
                                     |  on the Flash Utility Menu and
                                     |  follow the prompts. Then return
                                     |  to step 5. If CR2 continues to be
                                     |  off, replace the adapter battery.
   Note: If you reset the adapter by following the procedure
   'Resetting the Adapter and Clearing the Configuration', CR2 Dot will be off
   and you must select Update Service Processor on the Flash Utility
   menu.
 