Numeric Error Codes (Netfinity 7000 - 8651)



  Error Codes (Netfinity 7000 - 8651)

NOTE: - SCU= System Setup Utility Program

Error Code    FRU/Action.
  
0002 1. Cables
(Primary boot device not found) 2. Primary Boot Device
  
0010 1. Processor Module
(Cache memory failure, 2. Processor Board
do not enable cache)
0015 1. Primary Output Device
(Primary output device
not found)
0016 1. Primary Input Device
(Primary input device
not found)
0041 1. Reseat EISA Adapter
(EISA ID mismatch for slot) 2. Run SCU program
  3. EISA Adapter
  
0043 1. Reseat EISA Adapter
(EISA invalid configuration 2. Run SCU program
for slot)
0044 1. Reseat EISA Adapter
(EISA configuration not assured) 2. Run SCU program
  
0045 1. Reseat EISA Adapter
(EISA expansion board not 2. EISA Adapter
ready in slot) 3. System Board
  
0047 1. Run SCU program
(EISA CMOS configuration not set) 2. EISA Adapter
  3. System Board
  
0048 1. Run SCU program
(EISA CMOS checksum failure) 2. System Board
  
0049 1. Run SCU program
(EISA NVRAM invalid) 2. System Board
  
0050 1. Run SCU program
(Plug and Play Memory 2. ISA Adapter
Conflict)
0051 1. Run SCU program
(Plug and Play 32 bit 2. ISA Adapter
Memory Conflict)
0052 1. Run SCU program
(Plug and Play IRQ 2. ISA Adapter
Conflict)
0053 1. Run SCU program
(Plug and Play DMA 2. ISA Adapter
Conflict)
0054 1. Run SCU program
(Plug and Play Error 2. Clear CMOS and NVRAM
Log is Full)
0055 1. Run SCU program
(Bad Plug and Play Serial 2. ISA Adapter
ID Checksum)
0056 1. Run SCU program
(Bad Plug and Play Resource 2. ISA Adapter
Data Checksum)
0060 1. Unlock keyboard
(Keyboard is locked - 2. Keyboard
- please unlock it) 3. System Board
  
0070 1. Set time and date
(CMOS time and date not set) 2. Real-Time Clock Module
  
0080 1. Reseat adapter
(Option ROM has bad checksum) 2. Adapter
  
0081 1. Update User BIOS from latest Flash Diskette
(Customer Binary Checksum 2. System Board
failure)
0083 1. Reseat adapter
(Shadow of PCI ROM failed) 2. Adapter
  
0084 1. Reseat adapter
(Shadow of EISA ROM failed) 2. Adapter
  
0085 1. Reseat adapter
(Shadow of ISA ROM failed) 2. Remove adapter
  
0131 1. Cable
(Floppy Drive A:) 2. Drive
  
0132 1. Cable
(Floppy Drive B:) 2. Drive
  
0135 1. System Board
(Floppy disk controller
failed)
0140 1. Reboot system
(Shadow of system BIOS 2. System Board
failed)
0162 1. Check for correct processor level
(Unable to apply BIOS 2. Processor 1 on Processor Board 1
Update for Slot 1
Processor 1)
0163 1. Check for correct processor level
(Unable to apply BIOS 2. Processor 2 on Processor Board 1
Update for Slot 1
Processor 2)
0164 1. Check for correct processor level
(Unable to apply BIOS 2. Processor 1 on Processor Board 2
Update for Slot 2
Processor 1)
0165 1. Check for correct processor level
(Unable to apply BIOS 2. Processor 2 on Processor Board 2
Update for Slot 2
Processor 2)
0166 1. Check for correct processor level
(BIOS does not support 2. Processor 1 on Processor Board 1
current stepping for Slot 1
Processor 1)
0167 1. Check for correct processor level
(BIOS does not support 2. Processor 2 on Processor Board 1
current stepping for Slot 1
Processor 2)
0168 1. Check for correct processor level
(BIOS does not support 2. Processor 1 on Processor Board 2
current stepping for Slot 2
Processor 1)
0169 1. Check for correct processor level
(BIOS does not support 2. Processor 2 on Processor Board 2
current stepping for Slot 2
Processor 2)
0170 1. Check for correct processor level
(Disable CPU Slot) 2. Processor 1 on Processor Board 1
current stepping for Slot 2
0171 1. Reseat processor module
(CPU failure - 2. Processor Module
- Slot 1, CPU # 1) 3. Processor Board
  
0172 1. Reseat processor module
(CPU failure - 2. Processor Module
- Slot 1, CPU # 2) 3. Processor Board
  
0173 1. Reseat processor module
(CPU failure - 2. Processor Module
- Slot 2, CPU # 1) 3. Processor Board
  
0174 1. Reseat processor module
(CPU failure - 2. Processor Module
- Slot 2, CPU # 2) 3. Processor Board
  
0175 1. Use compatible processor modules
(CPU modules are
incompatible)
0176 1. Reseat processor module
(CPU failure - Slot 1 2. Processor Module
CPU #1) 3. Processor Board
  
0177 1. Reseat processor module
(CPU failure - Slot 1 2. Processor Module
CPU #2) 3. Processor Board
  
0178 1. Reseat processor module
(CPU failure - Slot 2 2. Processor Module
CPU #1) 3. Processor Board
  
0179 1. Reseat processor module
(CPU failure - Slot 2 2. Processor Module
CPU #2) 3. Processor Board
  
0180 1. Processor Module
(Attempting to boot
with failed CPU)
0181 1. Information only
(Base System Processor
(BSP) switched, system may
not be in uni-processor
mode)
0191 1. Real-Time Clock Module
(CMOS battery failed) 2. System Board
  
0195 1. Run SCU program
(CMOS system options not set)
0198 1. Run SCU program
(CMOS checksum invalid)
0200 1. Check jumper settings
(Invalid voltage jumper for
processor in Slot 1
Processor 1)
0201 1. Check jumper settings
(Invalid voltage jumper for
processor in Slot 1
Processor 2)
0202 1. Check jumper settings
(Invalid voltage jumper for
processor in Slot 2
Processor 1)
0203 1. Check jumper settings
(Invalid voltage jumper for
processor in Slot 2
Processor 2)
0204 1. Information only
(CPU Removed - Slot 1
CPU 1)
0205 1. Information only
(CPU Removed - Slot 1
CPU 2)
0206 1. Information only
(CPU Removed - Slot 2
CPU 1)
0207 1. Information only
(CPU Removed - Slot 2
CPU 2)
0208 1. Processor 1 on
(CPU not responding     Processor Board 1
Slot 1 CPU 1)
0209 1. Processor 2 on
(CPU not responding     Processor Board 1
Slot 1 CPU 2)
0210 1. Processor 1 on
(CPU not responding     Processor Board 2
Slot 2 CPU 1)
0211 1. Processor 2 on
(CPU not responding     Processor Board 2
Slot 2 CPU 2)
0220 1. Fan Heat Sink on
(Fan Failure Slot 1     Processor 1 on
Processor 1)     Processor Board 1
  
0221 1. Fan Heat Sink on
(Fan Failure Slot 1     Processor 2 on
Processor 2)     Processor Board 1
  
0222 1. Fan Heat Sink on
(Fan Failure Slot 2     Processor 1 on
Processor 1)     Processor Board 2
  
0223 1. Fan Heat Sink on
(Fan Failure Slot 2     Processor 2 on
Processor 2)     Processor Board 2
  
0230 1. Run Flash Update
(Invalid processor for 2. Processor 1 on Processor Board 1
module in Slot 1     Processor Board 2
Processor 1)
0231 1. Run Flash Update
(Invalid processor for 2. Processor 2 on Processor Board 1
module in Slot 1     Processor Board 2
Processor 2)
0232 1. Run Flash Update
(Invalid processor for 2. Processor 1 on Processor Board 2
module in Slot 2     Processor Board 2
Processor 1)
0233 1. Run Flash Update
(Invalid processor for 2. Processor 2 on Processor Board 2
module in Slot 2     Processor Board 2
Processor 2)
0234 1. Check jumper settings on
(Processor cache jumper     processor board in slot 1
setting does not match cache 2. Processor 1 on Processor Board 1
size for module in Slot 1 3. Processor Board 1
Processor 1)
0235 1. Check jumper settings on
(Processor cache jumper     processor board in slot 1
setting does not match cache 2. Processor 2 on Processor Board 1
size for module in Slot 1 3. Processor Board 1
Processor 2)
0236 1. Check jumper settings on
(Processor cache jumper     processor board in slot 1
setting does not match cache 2. Processor 1 on Processor Board 2
size for module in Slot 2 3. Processor Board 2
Processor 1)
0237 1. Check jumper settings on
(Processor cache jumper     processor board in slot 1
setting does not match cache 2. Processor 2 on Processor Board 2
size for module in Slot 2 3. Processor Board 2
Processor 2)
0289 1. Run System Setup
(System memory size mismatch) 2. Memory SIMM
  3. Memory Board
  
0295 1. Memory SIMM
(Address line short detected) 2. Memory Board
  
0297 1. Run System Setup
(Memory size decreased) 2. Memory SIMM
  3. Memory Board
  
0299 1. Reseat memory and memory board
(ECC error correction failure) 2. Memory Board
  3. System Board
  
0301 1. Reseat memory and memory board
(ECC single bit correction 2. Memory Board
failed, correction disabled) 3. System Board
  
0302 1. Reseat memory and memory board
(ECC double bit error) 2. Memory Board
  3. System Board
  
0303 1. Reseat memory and memory board
(ECC SIMMS incompatible) 2. Memory Board
Memory failure during POST or 3. System Board
invalid DIMM combination
0304 1. Reseat memory and memory board
(Invalid memory configuration. 2. Memory Board
Memory failure during POST or 3. System Board
invalid combination on
DIMM sizes.)
0309 1. Reseat memory and memory board
(ECC Memory Failure) 2. Memory Board
  3. System Board
  
0310 1. Reseat memory and memory board
(ECC address failure 2. Memory Board
  3. System Board
  
0314 1. Refer to the 04XX error codes
(ECC Memory Size     displayed with this error code
Changes Bank 0)     to determine the failing DIMM
  
0315 1. Refer to the 04XX error codes
(ECC Memory Size     displayed with this error code
Changes Bank 1)     to determine the failing DIMM
  
0316 1. Refer to the 04XX error codes
(ECC Memory Size     displayed with this error code
Changes Bank 2)     to determine the failing DIMM
  
0317 1. Refer to the 04XX error codes
(ECC Memory Size     displayed with this error code
Changes Bank 3)     to determine the failing DIMM
  
0320 1. Reseat memory and memory board
(Adding/removing PCI 2. Memory Board
adapters has changed 3. System Board
available memory)
0322 1. Reseat memory and memory board
(An error has caused the 2. Memory Board
memory resizing to fail, 3. System Board
insufficient memory to
continue.)
0370 1. Reboot system
(Keyboard controller error) 2. System Board
  
0373 1. Ensure nothing is resting on the keyboard
(Keyboard stuck key detected) 2. Keyboard
  
0375 1. Swap keyboard and mouse
(Keyboard and mouse swapped)
0380 1. Replace memory as indicated
(ECC SIMM failure,
board is in slot 1)
0392 1. Replace memory as indicated
(ECC SIMM failure,
board is in slot 2)
0400 1. See 040X Interleave error
(DIMM error Bank 0)     for failing DIMM
  
0401 1. See 040X Interleave error
(DIMM error Bank 1)     for failing DIMM
  
0402 1. See 040X Interleave error
(DIMM error Bank 2)     for failing DIMM
  
0403 1. See 040X Interleave error
(DIMM error Bank 3)     for failing DIMM
  
0404 1. Memory DIMM
(DIMM error Interleave 0)
0405 1. Memory DIMM
(DIMM error Interleave 1)
0406 1. Memory DIMM
(DIMM error Interleave 2)
0407 1. Memory DIMM
(DIMM error Interleave 3)
0408 1. See 040x Interleave
(Unsupported Interleave 2 to 1)     error for failing DIMM
  
0430 1. System Board
(Timer channel 2 failure)
0440 1. System Board
(Gate-A20 failure)
0441 1. Use correct device driver
(Unexpected interrupted
in protected mode)
0445 1. System Board
(Master interrupt controller
error)
0446 1. System Board
(Slave interrupt controller
error)
0450 1. System Board
(Master DMA controller error)
0451 1. System Board
(Slave DMA controller error)
0452 1. System Board
(DMA controller error)
0460 1. Adapter
(Fail-safe timer NMI failure) 2. System Board
  
0461 1. Check software/device driver
(Software port NMI failure)
0465 1. Check adapter
(Bus timeout NMI in slot) 2. Adapter
  3. System Board
  
0467 1. Check adapter
(Expansion board NMI in slot) 2. Adapter
  
0501 1. PCI Device
(PCI system error) 2. System Board
  
0510 1. PCI device
(PCI parity error) 2. System Board
  
0511 1. PCI device
(PCI System error) 2. System Board
  
0710 1. Run SCU program
(System board device
resource conflict)
0711 1. Run SCU program
(Static device resource
conflict)
0780 1. PCI Adapter
(PCI Segment 1 memory
request exceeds 998 MB)
0781 1. PCI Adapter
(PCI Segment 1 I/O request
exceeds 12 K)
0782 1. PCI Adapter
(PCI I/O request exceeds
amount available)
0783 1. PCI Adapter
(PCI memory request exceeds
amount available)
0784 1. PCI Adapter
(Illegal bus for memory
request below 1 MB)
0785 1. PCI Adapter
(Memory request below 1 MB
exceeds 1 MB)
0800 1. Run SCU program
(PCI I/O port conflict)
0801 1. Run SCU program
(PCI memory conflict)
0802 1. Run SCU program
(PCI IRQ conflict)
0803 1. Rerun diagnostics
(PCI error log is full,
the log will be cleared
automatically)
0804 1. Information
(PCI ROM not found, may
2. PCI Adapter
be OK for this card)
0805 1. Remove PCI Adapter
(Insufficient Memory to
Shadow PCI ROM)
0806 1. PCI Adapter
(Memory Allocation Failure 2. System Board
to Second PCI Segment)
0809 1. Run SCU program
(PCI Error Log Full) 2. Clear NVRAM and CMOS
  
0810 1. Run SCU program
(Floppy disk controller
resource conflict)
0811 1. Check cables
  2. System Board
  
0812 1. Check cables
  2. System Board
  
0815 1. Run SCU program
(Parallel port resource
conflict)
0816 1. Run SCU program
(Serial port 1 resource
conflict)
0817 1. Run SCU program
(Serial port 2 resource
conflict)
0900 1. Run SCU program
(NVRAM checksum error,
NVRAM cleared)
0903 1. Run SCU program
(NVRAM DATA invalid,
NVRAM cleared)
0905 1. Run SCU program
(NVRAM cleared by jumper)
0906 1. Information
(Password Cleared by Jumper) 2. Set Password
  
0982 1. Adapter
(I/O expansion board 2. System Board
NMI in slot)
0984 1. Run SCU program
(Expansion board disabled 2. Adapter
in slot) 3. System Board
  
0985 1. Adapter
(Fail-safe timer NMI) 2. System Board
  
0986 1. Adapter
(System reset caused 2. System Board
by Watchdog Timer)
0987 1. Adapter
(Bus timeout NMI in slot) 2. System Board


More INFORMATION / HELP is available at the  IBM-HelpCenter