  Error Codes (Netfinity 7000 - 8651)
| Error Code | FRU/Action. | 
|---|---|
| 0002 | 1. Cables | 
| (Primary boot device not found) | 2. Primary Boot Device | 
| 0010 | 1. Processor Module | 
| (Cache memory failure, | 2. Processor Board | 
| do not enable cache) | |
| 0015 | 1. Primary Output Device | 
| (Primary output device | |
| not found) | |
| 0016 | 1. Primary Input Device | 
| (Primary input device | |
| not found) | |
| 0041 | 1. Reseat EISA Adapter | 
| (EISA ID mismatch for slot) | 2. Run SCU program | 
| 3. EISA Adapter | |
| 0043 | 1. Reseat EISA Adapter | 
| (EISA invalid configuration | 2. Run SCU program | 
| for slot) | |
| 0044 | 1. Reseat EISA Adapter | 
| (EISA configuration not assured) | 2. Run SCU program | 
| 0045 | 1. Reseat EISA Adapter | 
| (EISA expansion board not | 2. EISA Adapter | 
| ready in slot) | 3. System Board | 
| 0047 | 1. Run SCU program | 
| (EISA CMOS configuration not set) | 2. EISA Adapter | 
| 3. System Board | |
| 0048 | 1. Run SCU program | 
| (EISA CMOS checksum failure) | 2. System Board | 
| 0049 | 1. Run SCU program | 
| (EISA NVRAM invalid) | 2. System Board | 
| 0050 | 1. Run SCU program | 
| (Plug and Play Memory | 2. ISA Adapter | 
| Conflict) | |
| 0051 | 1. Run SCU program | 
| (Plug and Play 32 bit | 2. ISA Adapter | 
| Memory Conflict) | |
| 0052 | 1. Run SCU program | 
| (Plug and Play IRQ | 2. ISA Adapter | 
| Conflict) | |
| 0053 | 1. Run SCU program | 
| (Plug and Play DMA | 2. ISA Adapter | 
| Conflict) | |
| 0054 | 1. Run SCU program | 
| (Plug and Play Error | 2. Clear CMOS and NVRAM | 
| Log is Full) | |
| 0055 | 1. Run SCU program | 
| (Bad Plug and Play Serial | 2. ISA Adapter | 
| ID Checksum) | |
| 0056 | 1. Run SCU program | 
| (Bad Plug and Play Resource | 2. ISA Adapter | 
| Data Checksum) | |
| 0060 | 1. Unlock keyboard | 
| (Keyboard is locked - | 2. Keyboard | 
| - please unlock it) | 3. System Board | 
| 0070 | 1. Set time and date | 
| (CMOS time and date not set) | 2. Real-Time Clock Module | 
| 0080 | 1. Reseat adapter | 
| (Option ROM has bad checksum) | 2. Adapter | 
| 0081 | 1. Update User BIOS from latest Flash Diskette | 
| (Customer Binary Checksum | 2. System Board | 
| failure) | |
| 0083 | 1. Reseat adapter | 
| (Shadow of PCI ROM failed) | 2. Adapter | 
| 0084 | 1. Reseat adapter | 
| (Shadow of EISA ROM failed) | 2. Adapter | 
| 0085 | 1. Reseat adapter | 
| (Shadow of ISA ROM failed) | 2. Remove adapter | 
| 0131 | 1. Cable | 
| (Floppy Drive A:) | 2. Drive | 
| 0132 | 1. Cable | 
| (Floppy Drive B:) | 2. Drive | 
| 0135 | 1. System Board | 
| (Floppy disk controller | |
| failed) | |
| 0140 | 1. Reboot system | 
| (Shadow of system BIOS | 2. System Board | 
| failed) | |
| 0162 | 1. Check for correct processor level | 
| (Unable to apply BIOS | 2. Processor 1 on Processor Board 1 | 
| Update for Slot 1 | |
| Processor 1) | |
| 0163 | 1. Check for correct processor level | 
| (Unable to apply BIOS | 2. Processor 2 on Processor Board 1 | 
| Update for Slot 1 | |
| Processor 2) | |
| 0164 | 1. Check for correct processor level | 
| (Unable to apply BIOS | 2. Processor 1 on Processor Board 2 | 
| Update for Slot 2 | |
| Processor 1) | |
| 0165 | 1. Check for correct processor level | 
| (Unable to apply BIOS | 2. Processor 2 on Processor Board 2 | 
| Update for Slot 2 | |
| Processor 2) | |
| 0166 | 1. Check for correct processor level | 
| (BIOS does not support | 2. Processor 1 on Processor Board 1 | 
| current stepping for Slot 1 | |
| Processor 1) | |
| 0167 | 1. Check for correct processor level | 
| (BIOS does not support | 2. Processor 2 on Processor Board 1 | 
| current stepping for Slot 1 | |
| Processor 2) | |
| 0168 | 1. Check for correct processor level | 
| (BIOS does not support | 2. Processor 1 on Processor Board 2 | 
| current stepping for Slot 2 | |
| Processor 1) | |
| 0169 | 1. Check for correct processor level | 
| (BIOS does not support | 2. Processor 2 on Processor Board 2 | 
| current stepping for Slot 2 | |
| Processor 2) | |
| 0170 | 1. Check for correct processor level | 
| (Disable CPU Slot) | 2. Processor 1 on Processor Board 1 | 
| current stepping for Slot 2 | |
| 0171 | 1. Reseat processor module | 
| (CPU failure - | 2. Processor Module | 
| - Slot 1, CPU # 1) | 3. Processor Board | 
| 0172 | 1. Reseat processor module | 
| (CPU failure - | 2. Processor Module | 
| - Slot 1, CPU # 2) | 3. Processor Board | 
| 0173 | 1. Reseat processor module | 
| (CPU failure - | 2. Processor Module | 
| - Slot 2, CPU # 1) | 3. Processor Board | 
| 0174 | 1. Reseat processor module | 
| (CPU failure - | 2. Processor Module | 
| - Slot 2, CPU # 2) | 3. Processor Board | 
| 0175 | 1. Use compatible processor modules | 
| (CPU modules are | |
| incompatible) | |
| 0176 | 1. Reseat processor module | 
| (CPU failure - Slot 1 | 2. Processor Module | 
| CPU #1) | 3. Processor Board | 
| 0177 | 1. Reseat processor module | 
| (CPU failure - Slot 1 | 2. Processor Module | 
| CPU #2) | 3. Processor Board | 
| 0178 | 1. Reseat processor module | 
| (CPU failure - Slot 2 | 2. Processor Module | 
| CPU #1) | 3. Processor Board | 
| 0179 | 1. Reseat processor module | 
| (CPU failure - Slot 2 | 2. Processor Module | 
| CPU #2) | 3. Processor Board | 
| 0180 | 1. Processor Module | 
| (Attempting to boot | |
| with failed CPU) | |
| 0181 | 1. Information only | 
| (Base System Processor | |
| (BSP) switched, system may | |
| not be in uni-processor | |
| mode) | |
| 0191 | 1. Real-Time Clock Module | 
| (CMOS battery failed) | 2. System Board | 
| 0195 | 1. Run SCU program | 
| (CMOS system options not set) | |
| 0198 | 1. Run SCU program | 
| (CMOS checksum invalid) | |
| 0200 | 1. Check jumper settings | 
| (Invalid voltage jumper for | |
| processor in Slot 1 | |
| Processor 1) | |
| 0201 | 1. Check jumper settings | 
| (Invalid voltage jumper for | |
| processor in Slot 1 | |
| Processor 2) | |
| 0202 | 1. Check jumper settings | 
| (Invalid voltage jumper for | |
| processor in Slot 2 | |
| Processor 1) | |
| 0203 | 1. Check jumper settings | 
| (Invalid voltage jumper for | |
| processor in Slot 2 | |
| Processor 2) | |
| 0204 | 1. Information only | 
| (CPU Removed - Slot 1 | |
| CPU 1) | |
| 0205 | 1. Information only | 
| (CPU Removed - Slot 1 | |
| CPU 2) | |
| 0206 | 1. Information only | 
| (CPU Removed - Slot 2 | |
| CPU 1) | |
| 0207 | 1. Information only | 
| (CPU Removed - Slot 2 | |
| CPU 2) | |
| 0208 | 1. Processor 1 on | 
| (CPU not responding | Processor Board 1 | 
| Slot 1 CPU 1) | |
| 0209 | 1. Processor 2 on | 
| (CPU not responding | Processor Board 1 | 
| Slot 1 CPU 2) | |
| 0210 | 1. Processor 1 on | 
| (CPU not responding | Processor Board 2 | 
| Slot 2 CPU 1) | |
| 0211 | 1. Processor 2 on | 
| (CPU not responding | Processor Board 2 | 
| Slot 2 CPU 2) | |
| 0220 | 1. Fan Heat Sink on | 
| (Fan Failure Slot 1 | Processor 1 on | 
| Processor 1) | Processor Board 1 | 
| 0221 | 1. Fan Heat Sink on | 
| (Fan Failure Slot 1 | Processor 2 on | 
| Processor 2) | Processor Board 1 | 
| 0222 | 1. Fan Heat Sink on | 
| (Fan Failure Slot 2 | Processor 1 on | 
| Processor 1) | Processor Board 2 | 
| 0223 | 1. Fan Heat Sink on | 
| (Fan Failure Slot 2 | Processor 2 on | 
| Processor 2) | Processor Board 2 | 
| 0230 | 1. Run Flash Update | 
| (Invalid processor for | 2. Processor 1 on Processor Board 1 | 
| module in Slot 1 | Processor Board 2 | 
| Processor 1) | |
| 0231 | 1. Run Flash Update | 
| (Invalid processor for | 2. Processor 2 on Processor Board 1 | 
| module in Slot 1 | Processor Board 2 | 
| Processor 2) | |
| 0232 | 1. Run Flash Update | 
| (Invalid processor for | 2. Processor 1 on Processor Board 2 | 
| module in Slot 2 | Processor Board 2 | 
| Processor 1) | |
| 0233 | 1. Run Flash Update | 
| (Invalid processor for | 2. Processor 2 on Processor Board 2 | 
| module in Slot 2 | Processor Board 2 | 
| Processor 2) | |
| 0234 | 1. Check jumper settings on | 
| (Processor cache jumper | processor board in slot 1 | 
| setting does not match cache | 2. Processor 1 on Processor Board 1 | 
| size for module in Slot 1 | 3. Processor Board 1 | 
| Processor 1) | |
| 0235 | 1. Check jumper settings on | 
| (Processor cache jumper | processor board in slot 1 | 
| setting does not match cache | 2. Processor 2 on Processor Board 1 | 
| size for module in Slot 1 | 3. Processor Board 1 | 
| Processor 2) | |
| 0236 | 1. Check jumper settings on | 
| (Processor cache jumper | processor board in slot 1 | 
| setting does not match cache | 2. Processor 1 on Processor Board 2 | 
| size for module in Slot 2 | 3. Processor Board 2 | 
| Processor 1) | |
| 0237 | 1. Check jumper settings on | 
| (Processor cache jumper | processor board in slot 1 | 
| setting does not match cache | 2. Processor 2 on Processor Board 2 | 
| size for module in Slot 2 | 3. Processor Board 2 | 
| Processor 2) | |
| 0289 | 1. Run System Setup | 
| (System memory size mismatch) | 2. Memory SIMM | 
| 3. Memory Board | |
| 0295 | 1. Memory SIMM | 
| (Address line short detected) | 2. Memory Board | 
| 0297 | 1. Run System Setup | 
| (Memory size decreased) | 2. Memory SIMM | 
| 3. Memory Board | |
| 0299 | 1. Reseat memory and memory board | 
| (ECC error correction failure) | 2. Memory Board | 
| 3. System Board | |
| 0301 | 1. Reseat memory and memory board | 
| (ECC single bit correction | 2. Memory Board | 
| failed, correction disabled) | 3. System Board | 
| 0302 | 1. Reseat memory and memory board | 
| (ECC double bit error) | 2. Memory Board | 
| 3. System Board | |
| 0303 | 1. Reseat memory and memory board | 
| (ECC SIMMS incompatible) | 2. Memory Board | 
| Memory failure during POST or | 3. System Board | 
| invalid DIMM combination | |
| 0304 | 1. Reseat memory and memory board | 
| (Invalid memory configuration. | 2. Memory Board | 
| Memory failure during POST or | 3. System Board | 
| invalid combination on | |
| DIMM sizes.) | |
| 0309 | 1. Reseat memory and memory board | 
| (ECC Memory Failure) | 2. Memory Board | 
| 3. System Board | |
| 0310 | 1. Reseat memory and memory board | 
| (ECC address failure | 2. Memory Board | 
| 3. System Board | |
| 0314 | 1. Refer to the 04XX error codes | 
| (ECC Memory Size | displayed with this error code | 
| Changes Bank 0) | to determine the failing DIMM | 
| 0315 | 1. Refer to the 04XX error codes | 
| (ECC Memory Size | displayed with this error code | 
| Changes Bank 1) | to determine the failing DIMM | 
| 0316 | 1. Refer to the 04XX error codes | 
| (ECC Memory Size | displayed with this error code | 
| Changes Bank 2) | to determine the failing DIMM | 
| 0317 | 1. Refer to the 04XX error codes | 
| (ECC Memory Size | displayed with this error code | 
| Changes Bank 3) | to determine the failing DIMM | 
| 0320 | 1. Reseat memory and memory board | 
| (Adding/removing PCI | 2. Memory Board | 
| adapters has changed | 3. System Board | 
| available memory) | |
| 0322 | 1. Reseat memory and memory board | 
| (An error has caused the | 2. Memory Board | 
| memory resizing to fail, | 3. System Board | 
| insufficient memory to | |
| continue.) | |
| 0370 | 1. Reboot system | 
| (Keyboard controller error) | 2. System Board | 
| 0373 | 1. Ensure nothing is resting on the keyboard | 
| (Keyboard stuck key detected) | 2. Keyboard | 
| 0375 | 1. Swap keyboard and mouse | 
| (Keyboard and mouse swapped) | |
| 0380 | 1. Replace memory as indicated | 
| (ECC SIMM failure, | |
| board is in slot 1) | |
| 0392 | 1. Replace memory as indicated | 
| (ECC SIMM failure, | |
| board is in slot 2) | |
| 0400 | 1. See 040X Interleave error | 
| (DIMM error Bank 0) | for failing DIMM | 
| 0401 | 1. See 040X Interleave error | 
| (DIMM error Bank 1) | for failing DIMM | 
| 0402 | 1. See 040X Interleave error | 
| (DIMM error Bank 2) | for failing DIMM | 
| 0403 | 1. See 040X Interleave error | 
| (DIMM error Bank 3) | for failing DIMM | 
| 0404 | 1. Memory DIMM | 
| (DIMM error Interleave 0) | |
| 0405 | 1. Memory DIMM | 
| (DIMM error Interleave 1) | |
| 0406 | 1. Memory DIMM | 
| (DIMM error Interleave 2) | |
| 0407 | 1. Memory DIMM | 
| (DIMM error Interleave 3) | |
| 0408 | 1. See 040x Interleave | 
| (Unsupported Interleave 2 to 1) | error for failing DIMM | 
| 0430 | 1. System Board | 
| (Timer channel 2 failure) | |
| 0440 | 1. System Board | 
| (Gate-A20 failure) | |
| 0441 | 1. Use correct device driver | 
| (Unexpected interrupted | |
| in protected mode) | |
| 0445 | 1. System Board | 
| (Master interrupt controller | |
| error) | |
| 0446 | 1. System Board | 
| (Slave interrupt controller | |
| error) | |
| 0450 | 1. System Board | 
| (Master DMA controller error) | |
| 0451 | 1. System Board | 
| (Slave DMA controller error) | |
| 0452 | 1. System Board | 
| (DMA controller error) | |
| 0460 | 1. Adapter | 
| (Fail-safe timer NMI failure) | 2. System Board | 
| 0461 | 1. Check software/device driver | 
| (Software port NMI failure) | |
| 0465 | 1. Check adapter | 
| (Bus timeout NMI in slot) | 2. Adapter | 
| 3. System Board | |
| 0467 | 1. Check adapter | 
| (Expansion board NMI in slot) | 2. Adapter | 
| 0501 | 1. PCI Device | 
| (PCI system error) | 2. System Board | 
| 0510 | 1. PCI device | 
| (PCI parity error) | 2. System Board | 
| 0511 | 1. PCI device | 
| (PCI System error) | 2. System Board | 
| 0710 | 1. Run SCU program | 
| (System board device | |
| resource conflict) | |
| 0711 | 1. Run SCU program | 
| (Static device resource | |
| conflict) | |
| 0780 | 1. PCI Adapter | 
| (PCI Segment 1 memory | |
| request exceeds 998 MB) | |
| 0781 | 1. PCI Adapter | 
| (PCI Segment 1 I/O request | |
| exceeds 12 K) | |
| 0782 | 1. PCI Adapter | 
| (PCI I/O request exceeds | |
| amount available) | |
| 0783 | 1. PCI Adapter | 
| (PCI memory request exceeds | |
| amount available) | |
| 0784 | 1. PCI Adapter | 
| (Illegal bus for memory | |
| request below 1 MB) | |
| 0785 | 1. PCI Adapter | 
| (Memory request below 1 MB | |
| exceeds 1 MB) | |
| 0800 | 1. Run SCU program | 
| (PCI I/O port conflict) | |
| 0801 | 1. Run SCU program | 
| (PCI memory conflict) | |
| 0802 | 1. Run SCU program | 
| (PCI IRQ conflict) | |
| 0803 | 1. Rerun diagnostics | 
| (PCI error log is full, | |
| the log will be cleared | |
| automatically) | |
| 0804 | 1. Information | 
| (PCI ROM not found, may | |
| 2. PCI Adapter | |
| be OK for this card) | |
| 0805 | 1. Remove PCI Adapter | 
| (Insufficient Memory to | |
| Shadow PCI ROM) | |
| 0806 | 1. PCI Adapter | 
| (Memory Allocation Failure | 2. System Board | 
| to Second PCI Segment) | |
| 0809 | 1. Run SCU program | 
| (PCI Error Log Full) | 2. Clear NVRAM and CMOS | 
| 0810 | 1. Run SCU program | 
| (Floppy disk controller | |
| resource conflict) | |
| 0811 | 1. Check cables | 
| 2. System Board | |
| 0812 | 1. Check cables | 
| 2. System Board | |
| 0815 | 1. Run SCU program | 
| (Parallel port resource | |
| conflict) | |
| 0816 | 1. Run SCU program | 
| (Serial port 1 resource | |
| conflict) | |
| 0817 | 1. Run SCU program | 
| (Serial port 2 resource | |
| conflict) | |
| 0900 | 1. Run SCU program | 
| (NVRAM checksum error, | |
| NVRAM cleared) | |
| 0903 | 1. Run SCU program | 
| (NVRAM DATA invalid, | |
| NVRAM cleared) | |
| 0905 | 1. Run SCU program | 
| (NVRAM cleared by jumper) | |
| 0906 | 1. Information | 
| (Password Cleared by Jumper) | 2. Set Password | 
| 0982 | 1. Adapter | 
| (I/O expansion board | 2. System Board | 
| NMI in slot) | |
| 0984 | 1. Run SCU program | 
| (Expansion board disabled | 2. Adapter | 
| in slot) | 3. System Board | 
| 0985 | 1. Adapter | 
| (Fail-safe timer NMI) | 2. System Board | 
| 0986 | 1. Adapter | 
| (System reset caused | 2. System Board | 
| by Watchdog Timer) | |
| 0987 | 1. Adapter | 
| (Bus timeout NMI in slot) | 2. System Board | 
Please see the LEGAL  -  Trademark notice.