PCNTNW-OS2-1 The LSL is not loaded.
Explanation: The Link Support Layer module (LSL.SYS) is not loaded.
Action: Load LSL.SYS before loading
the driver.
PCNTNW-OS2-21 Could not add the MLID Protocol ID.
Explanation: The PCNTNW MLID could not register the specified
Protocol ID.
Action: Edit the NET.CFG file and correct
the protocol information.
PCNTNW-OS2-22 Could not allocate memory. The virtual board did not load.
Explanation: The driver
could not allocate memory for the virtual adapter.
Action: Check the system configuration.
PCNTNW-OS2-54 The board did not respond to the initialization command.
Explanation: The board initialization failed.
Action: Perform the following steps:
PCNTNW-OS2-56 This interrupt is already used and cannot be shared.
Explanation: The interrupt is already used by another device
and cannot be shared.
Action: Assign a different IRQ in the Configuration/Setup utility programs.
See 'PCI Bus Control' for information on setting the interrupt
requests.
PCNTNW-OS2-58 The board did not respond to the initialization command.
Explanation: The IRQ setting might be incorrect with the hardware
setting, or the EEPROM might be corrupted.
Action: Verify that
the IRQ settings in the NET.CFG file
match the configuration settings in the Configuration/Setup utility programs.
See 'PCI Bus Control' for information on setting the interrupt
requests.
Verify that the EEPROM on the system board is programmed correctly.
PCNTNW-OS2-61 PCI device IRQ number mismatch.
Explanation: The IRQ number specified in the NET.CFG file
does not match with the
IRQ number assigned in the Configuration/Setup utility programs.
The IRQ numbers might be assigned automatically, or you might have
manually assigned the IRQ number.
Action: Remove the IRQ number in the NET.CFG file.
Or, see 'PCI Bus Control' for information on setting the interrupt
requests.
PCNTNW-OS2-64 The device was not found.
Explanation: The driver cannot find the Ethernet controller in the server.
Action: Verify that the Ethernet enable jumper is set to the default
(enable) position.
Go to General Checkout/Diagnostics QAPlus/PRO to run the diagnostic utility.
PCNTNW-OS2-65 Device not found at IOADDRESS.
Explanation: The Ethernet controller
cannot be found at the IO address specified
in the NET.CFG file.
Action: Verify that the IO address in NET.CFG matches with the board.
Otherwise, remove the PORT keyword from the NET.CFG file.
PCNTNW-OS2-67 PCI scan specified, device not found.
Explanation: The driver
cannot locate the Ethernet controller on the PCI bus.
Action: Perform the following steps
PCNTNW-OS2-73 Unable to allocate memory.
Explanation: The driver
could not allocate memory for the virtual board.
Action: Check the system configuration.
PCNTNW-OS2-80 The DMA parameter is not necessary to PCI device.
The DMA parameter is not necessary to PCI device.
Explanation: The Ethernet controller does not require a DMA setting.
This parameter is not a valid driver parameter.
Action: Edit the NET.CFG file to delete the DMA parameter.