Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

NETFINITY 7000-M10 500/550MHZ PROCESSOR JUMPER SETTINGS



Subject: NETFINITY 7000-M10 500/550MHZ PROCESSOR JUMPER SETTINGS
New Netfinity server RETAIN Tip: 

    Record number:       H054408
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00001
    Success count:       USC0000
    Publication code:    PC30
    Tip key:             001
    Date created:        O99/06/17
    Date last altered:   A99/06/22
    Owning B.U.:         EMA


Abstract: NETFINITY 7000-M10 500/550MHZ PROCESSOR JUMPER SETTINGS


TEXT:

HMM Documentation Update

Some older documentation for the Netfinity 7000-M10 does not give the jumper settings for 500MHz and 550MHz Pentium III Xeon Upgrade Processor Options.
The documentation also states that for Processor speeds above 450MHz the jumper settings are not important as speed is set automatically.

THIS IS FALSE.

All Netfinity 7000-M10 systems require a jumper settings for all processor speeds.
The jumper settings for the various speeds are as follows:

   SPEED    J46     J45    J44    J43
   400MHz   1-2     1-2    1-2    2-3
   450MHz   1-2     2-3    1-2    2-3
   500MHz   1-2     1-2    2-3    2-3
   550MHz   1-2     2-3    2-3    2-3

Pentium and Xeon are trademarks of Intel Corporation in the United States and/or other countries.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.