Record number: H167030
Device: D/T8680
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/07/28
Date last altered: A99/07/30
Owning B.U.: USA
Abstract: OS/2 SMP 4.0: SYS1919 ERROR WHEN INSTALLING FROM SERVERGUIDE
TEXT:
OS/2 SMP 4.0: SYS1919 error when installing from ServerGuide.
SYMPTOMS:
When installing OS/2 SMP 4.0 using ServerGuide the following error message could be displayed:
"SYS1919: The file x:\CID\LOCINSTU\SRVREXX.EXE specified
in the run statement on line yy of the CONFIG.SYS does
not contain a valid program. Line yy is ignored."
Where x is the CD-ROM driver and yy is a line number in the CONFIG.SYS file.
PROBLEM ISOLATION AIDS:
a Netfinity 7000-M10 server, Type 8680, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 5500-M20 server, Type 8662, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 3500 server, Type 8644, any Model.
a Netfinity 3000 server, Type 8476, any Model.
a Netfinity 1000 server, Type 8477, any Model.
WORKAROUND:
While installing OS/2 SMP, in the "System Configuration" screen, change the default value ( OTHER ) of the "CD-ROM
Device Support" section to the CD-ROM driver installed in your system.
You can change this value as follow:
Note: If your CD-ROM is not listed and your system has an IDE CD-ROM select the "Non-listed IDE CD-ROM".
DETAILS:
This is a limitation in OS/2 SMP 4.0.
This version sometimes can not automatically detect the newest CD-ROMs drives and in order to successfully
install OS/2 SMP 4.0 the CD-ROM has to be manually selected.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.