Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

5V REGULATOR CARD CAN EXHIBIT A CAP BURNOUT FAIL



Subject: POWER CONTROL CARD CAN EXHIBIT A CAPACITOR BURNOUT FAILURE
Updated Netfinity server RETAIN Tip: 

    Record number:       H166727
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00015
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O99/06/10
    Date last altered:   A99/06/29
    Owning B.U.:         USA


Abstract: POWER CONTROL CARD CAN EXHIBIT A CAPACITOR BURNOUT FAILURE


SYMPTOM:


PROBLEM ISOLATION AIDS:


FIX:

The Power Control Card and Bracket, FRU P/N 03K9097 (5v regulator card) was manufactured with incorrect cap value 16v instead of correct 20v value.
This error was fixed in EC# E73186A.


WORKAROUND:

If capacitor fails, replace card in system.


DETAILS:

Some cards may fail in system with a start up surge voltage.
16v capacitor will not handle as much surge as 20v capacitor.
There is no way to determine if and when capacitor will fail.
Only known fails were on pre-GA product.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.