Record number: H166630
Device: D/T8680
Model: M
Hit count: UHC00015
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/05/20
Date last altered: A99/06/04
Owning B.U.: USA
Abstract: SERVERAID: SOME PFA DRIVES CAUSE BOOT CONFIG MISMATCH
SYMPTOM:
The message and count down that says "Drive Configuration can take up to 6 minutes" Please wait
The count down takes longer than 4 minutes.
Then the message:
Controller POST and Configuration Error Codes:
ISPR=EF10, BCS=7, ECS=00.
Unable to communicate with the following devices.
(Channel: SID) (X:Y)
Controller OK, Devices not responding check cable or enclosures.
Press: F4 - Retry the command
F10 - Exit without any change
Where X and Y are the Channel and ID of the PFA drive.
PROBLEM ISOLATION AIDS:
a Netfinity 7000-M10 server, Type 8680, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 5500-M20 server, Type 8662, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 3500 server, Type 8644, any Model.
a Netfinity 3000 server, Type 8476, any Model.
a Netfinity 1000 server, Type 8477, any Model.
a PC Server 704, Type 8650, any Model.
a PC Server 520, Type 8641, any Model.
a PC Server 330, Type 8640, any Model.
a PC Server 325, Type 8639, any Model.
a PC Server 320, Type 8640, any Model.
a PC Server 315, Type 8638, any Model.
Onboard ServeRAID
a PC ServeRAID SCSI Adapter, Option P/N 70G8489
a ServeRAID II Ultra SCSI Adapter, Option P/N 76H3584
a Netfinity ServeRAID-3H Ultra2 SCSI Adapter, Option P/N 01K7207
a Netfinity ServeRAID-3L Ultra2 SCSI Adapter, Option P/N 01K7364
a Netfinity 9.1GB 10,000rpm Wide Ultra SCSI Hot-Swap
SCA-2 SL HDD, FRU P/N 10L6018
a Netfinity 18.2GB 10,000rpm Wide Ultra SCSI Hot-Swap
SCA-2 HDD, FRU P/N 10L6047
FIX:
Replace the PFA drive.
Note: The non responding drive described in the SYMPTOM section
should be checked for PFA status.
June 22, 1999.
http://www.pc.ibm.com/searchfiles.html
search on "ServeRAID firmware"
only get version 3.50.15 or higher.
Notes:
WORKAROUND:
If you get a "Configuration Change Error" when the system is warm booted, Select F4 (retry).
Note: Do NOT select F10 (no change).
-IMPORTANT: - If F10 was selected by accident -- Contact your
appropriate geography's HelpCenter,
(e.g. in the U.S., contact the IBM HelpCenter at 1-800-772-2227).
Note: "Worldwide HelpCenter Phone List" is available at the following URL:
http://www.pc.ibm.com/support?page=YAST-3P2QYL
DETAILS:
The drive is alerting the ServeRAID adapter of the PFA error before the adapter is set up to handle the alert correctly.
Note: Any Drive in a PFA state should be replaced as soon as possible.
Please see the LEGAL - Trademark notice.