Record number: H166509
Device: D/T8680
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/05/05
Date last altered: A99/05/18
Owning B.U.: USA
Abstract: NETFINITY 5000: RAS ADAPTERS ONLY WORK IN SLOT-5
SYMPTOM:
IBM (RAS) adapter, (Option P/N 33L4645 + 33L4646, FRU P/N 33L4612 + 33L4613), or the IBM 4P BRI ST/U adapter,
(Option P/N 33L4643 + 33L4644, FRU P/N 33L4610 + 33L4611), installed in an IBM Netfinity 5000 server (8659) only
works in Slot-5. (Non shared ISA/PCI slot.)
PROBLEM ISOLATION AIDS:
a Netfinity 3000 server, Type 8476, any Model.
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 7000-M10 server, Type 8680, any Model.
NOTE - The current list of products that have been tested with current models of IBM Netfinity and PC Servers is available at the following URL:
http://www.pc.ibm.com/us/compat/
click on "Wide-Area Networking"
FIX:
WORKAROUND:
Verify that the card is installed in the correct slot.
If the card is not installed in slot 5, remove the adapter software and the adapter.
Then re-install the adapter in slot-5, and re-install the software.
Note: See your users guide for detailed information about adapter hardware
and software installation and configuration.
- OR -
Update the BIOS on the Netfinity 5000 (8659) to Level-7 v1.04 or higher.
DETAILS:
The IBM RAS adapter or the IBM 4P BRI ST/U adapter should be installed only in slot-5
in a Netfinity 5000 (8659) if the BIOS is below Level-7 v1.04.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.