NETFINITY 5000 BIOS 28A REQUIRED FOR ADVANCED SERIALRAID/X



Subject: NETFINITY 5000 BIOS 28A REQUIRED FOR ADVANCED SERIALRAID/X
New Netfinity server RETAIN Tip: 

    Record number:       H166366
    Device:              D/T8659
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O99/04/22
    Date last altered:   A99/04/22
    Owning B.U.:         USA


Abstract: NETFINITY 5000 BIOS 28A REQUIRED FOR ADVANCED SERIALRAID/X


SYMPTOM:

A range of failures including crashes, hangs, and blue screens.


PROBLEM ISOLATION AIDS:


FIX:

Install Netfinity 5000 BIOS Version 1.04 / level 7.0 (28a) or higher before installing the SSA adapter.

This BIOS version is available at the following URL:

http://www.pc.ibm.com/support?page=IBM+PC+Server
Select "Netfinity 5000",
then select "Downloadable files",
then select "BIOS".
Download and install per README instructions.


DETAILS:

An incompatibility exists between the Advanced SerialRAID/X Adapter and Netfinity 5000 BIOS levels prior to Version 1.04 Level 7.0 (28a).
It relates to how the system reads the Adapter's registers on the PCI bus.
This incompatibility will result in multiple failures. This incompatibility is fixed in BIOS Version 1.04 / Level 7.0 (28a), released 1999-03-17.