Record number: H166366
Device: D/T8659
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/04/22
Date last altered: A99/04/22
Owning B.U.: USA
Abstract: NETFINITY 5000 BIOS 28A REQUIRED FOR ADVANCED SERIALRAID/X
SYMPTOM:
A range of failures including crashes, hangs, and blue screens.
PROBLEM ISOLATION AIDS:
Advanced SerialRAID Adapter/X, Option P/N 09L2123, FRU P/N 09L2124
FIX:
Install Netfinity 5000 BIOS Version 1.04 / level 7.0 (28a) or higher before installing the SSA adapter.
This BIOS version is available at the following URL:
http://www.pc.ibm.com/support?page=IBM+PC+Server
Select "Netfinity 5000",
then select "Downloadable files",
then select "BIOS".
Download and install per README instructions.
DETAILS:
An incompatibility exists between the Advanced SerialRAID/X Adapter and Netfinity 5000 BIOS
levels prior to Version 1.04 Level 7.0 (28a).
It relates to how the system reads the Adapter's registers on the PCI bus.
This incompatibility will result in multiple failures. This incompatibility is fixed in
BIOS Version 1.04 / Level 7.0 (28a), released 1999-03-17.