Record number: H166357
Device: D/T8644
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/04/19
Date last altered: A99/04/19
Owning B.U.: USA
Abstract: 1962 POST CAUSED BY INCORRECT INSTALLATION OF SCSI CABLE
TEXT:
1962 POST caused by incorrect installation of SCSI cable.
SYMPTOMS:
PROBLEM ISOLATION AIDS:
SCSI cable P/N 02K1416 FRU P/N 01K1481
FIX:
Note: The velcro will adhere to the HDD case.
Note: The terminator will be fastened to the top of the chassis using the velcro on the terminator.
Note: Position approx 1.5 inches from the P.S. and center between the chassis sides.
DETAILS:
A new cable is being shipped in the Netfinity 3500.
If this cable is not installed correctly system could experience 1962 errors from cable coming loose.
When the velcro is not properly utilized, the cable will not function correctly.
Connections to SCSI devices (including boot devices) can be lost.
Please see the LEGAL - Trademark notice.