Record number: H166308
Device: D/T8659
Model: M
Hit count: UHC00011
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/03/04
Date last altered: A99/04/15
Owning B.U.: USA
Abstract: NETFINITY 5000: WINDOWS NT INSTALLATION FAILS, SYSTEM HALTED
SYMPTOM:
Note: This problem is not seen when the Fibre Channel Host Bus Adapter is on bus-0, slot5.
"Call your Hardware Vendor, system Halted"
Note: This is after mass storage devices are loaded and the system reboots.
PROBLEM ISOLATION AIDS:
"Call your Hardware Vendor, system Halted"
FIX:
Two possible fixes:
Note: If this fails, use second fix (below).
DETAILS:
A number of drivers are loaded by default in order to be able to install from the CD without special driver diskettes.
These drivers ask Windows NT for specific resources, and if no other driver has claimed them, will attempt their private detection
methods.
These drivers are ones that are submitted to Microsoft for inclusion on the CD.
If the driver is loaded, it will claim its addresses.
These private detection methods may try to talk to areas they do not own in incompatible ways.
TRADEMARKS:
Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States and/or
other countries.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.