Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

SYSTEM CLOCK (TIME) IS AFFECTED AFTER BOOTING FROM CD



Subject: SYSTEM CLOCK (TIME) IS AFFECTED AFTER BOOTING FROM CD
New Netfinity server RETAIN Tip: 

    Record number:       H166305
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:             017
    Date created:        O99/03/23
    Date last altered:   A99/03/31
    Owning B.U.:         USA


Abstract: SYSTEM CLOCK (TIME) IS AFFECTED AFTER BOOTING FROM CD


TEXT:

System clock (time) is affected after booting from CD


SYMPTOMS:

The system's time has been changed back one (1) hour.


PROBLEM ISOLATION AIDS:



a Netfinity 7000-M10 server, Type 8680, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 5500-M20 server, Type 8662, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 3500 server, Type 8644, any Model.
a Netfinity 3000 server, Type 8476, any Model.


FIX:


WORKAROUND:

Be certain to check the system clock for the correct time after booting from the ServeRAID Configuration CD ROM or the Server Guide (Hardware Guide) CD-ROM.


DETAILS:

When the ServeRAID Configuration (Version lower than 3.50.04)
CD-ROM or the Server Guide (Version lower than 3.50.04)
CD-ROM Graphical user Interface boots, the system clock can be set back one hour.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.