Record number: H166171
Device: D/T9086
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/02/23
Date last altered: A99/03/30
Owning B.U.: USA
Abstract: 9086-001: HANGS UNLOADING PBXAAPI OR SHUTTING DOWN NETWARE
SYMPTOM:
The PCI ESCON adapter may not work properly in certain hardware platforms.
Under NetWare, unloading the PBXAAPI.NLM after active connections were established will hang the server.
This is noticed when the CHLDOWN.NCF is used. Also, when shutting down the server (i.e. DOWN and EXIT),
the server will hang after typing the EXIT.
Under Windows NT no problems were reported.
PROBLEM ISOLATION AIDS:
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 7000-M10 server, Type 8680, any Model.
FIX:
Download escon531.exe & escon531.txt from the following URL:
http://www.pc.ib.com/searchfiles.html
search on "escon531"
Follow the instructions in the escon531.txt.
DETAILS:
The Firmware for the ESCON Adapter is affected.
NOTE: It is recommended this update be applied to all ESCON adapters with a POST version of 5.7 or below.
TRADEMARKS:
Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States and/or
other countries.
Other company, product and service names may be the trademarks or service marks of others.
Please see the LEGAL - Trademark notice.