Record number: H166165
Device: D/T8651
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/03/26
Date last altered: A99/03/26
Owning B.U.: USA
Abstract: NETFINITY 7000 OR PC SERVER 704: PERFORMANCE PROBLEMS
TEXT:
Netfinity 7000 & PC Server 704: performance problems
SYMPTOMS:
Performance problems.
PROBLEM ISOLATION AIDS:
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 704 server, Type 8650, any Model.
FIX:
Reboot the system into the F1 Set-up Utility.
Choose "Advanced" from the top of the screen, then choose "Advanced Chipset Configuration".
Check the setting of "Cache Mode", it must be "Write Back."
If it is set to "Write Thru" then a severe performance issue will be seen on the server and the setting
needs to be changed to "Write Back".