Record number: H165927
Device: D/T8644
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/01/27
Date last altered: A99/02/17
Owning B.U.: USA
Abstract: SERVERAID II with NVRAM BATTERY CACHE PROBLEMS
TEXT:
There can be problems with using the 2.87 Firmware with the ServeRAID II adapter and the
NVRAM Battery Backup Cache in combination.
SYMPTOMS:
Note: This may be seen when installing Operating systems, or during file transfers, or other I/O activity.
PROBLEM ISOLATION AIDS:
Note: The Netfinity ServerProven Compatibility web page is at the following URL:
http://www.pc.ibm.com/us/compat/
Note: This problem is not seen in RAID-5, or RAID-0, or in Write-Through Mode.
FIX
The fix for this problem is in the IBM ServeRAID BIOS Firmware Update Diskette v3.11.
The fix is to upgrade the BIOS and Firmware to this level or greater.
IBM ServeRAID BIOS Firmware Update Diskette v3.11 is to be used in conjunction with the 3.10 versions of the ServeRAID software
(i.e. Device Drivers, Command Line Utilities, ServeRAID Administration Utility, etc.).
If the server is not currently at the 3.10 level of ServeRAID software, IBM recommends that you update to 3.10 versions of ServeRAID
software at the same time you are updating to the 3.11 ServeRAID BIOS/Firmware.
The fix, version 3.11 or later, and the other recommended ServeRAID diskettes can be downloaded from the following URL:
http://www.pc.ibm.com/searchfiles.html
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.