Record number: H166312
Device: D/T3526 Service code: 33
ECA number: ECA029 Parts source: LOC
EC number: ECE73145 Publish flag: R
Mandatory: Y Hit count: UHC00003
Automatic shipment: N Success count: USC0000
Availability date: 99/02 Publication code: PC50
Plant of control: 23 Date created: O99/04/13
Tip key: Date last altered: A99/04/15
Owning B.U.: USA
Abstract: ECA029: REPLACEMENT OF NETFINITY FIBRE CHANNEL CONTROLLER
PURPOSE:
This ECA provides for the replacement of the Netfinity Fibre Channel RAID Controller
(Standard Controller shipped in the 3526) and the Netfinity Fibre Channel Failsafe RAID Controller.
Product evaluations at IBM have revealed that you may experience Fibre Controller hangs, reboots,
a failed controller and possibly incorrect data with or without an error message when using the
Netfinity Fibre Channel RAID Controller and/or the Netfinity Channel Failsafe RAID Controller.
Customers should replace the Netfinity Fibre Channel Controller, and, if installed, the
Netfinity Fibre Channel Failsafe RAID Controller as soon as possible.
This ECA is "MANDATORY".
FEATURES:
Type, Machines Affected
Model, With and/or Feature/Device B/M to be Service System
Stage B/M Description Installed Hours Hours
3526 B/M0000000 FIBRE CHAN. CONTROLLER B/M37L0412 00.5 00.3
PHYSICAL CHECK:
PREREQUISITES:
IBM recommends that the customer backup his data prior to the installation of these parts.
The following applies only if the 3526 has more than one (1) controller installed:
If both of the controllers in the 3526 are identified as needing to be replaced, you must have two (2) new controllers
on hand -- one for each, so that both are replaced at the same time.
Note: You cannot replace one now and one later, it is a technical requirement that they both be
replaced at the same time.
COMPANION: NONE
CONCURRENT: NONE
DETAIL:
Replace the Netfinity Fibre Channel RAID Controller (FRU P/N 10L6993), and if installed, the Netfinity Fibre Channel
Failsafe RAID Controller (FRU P/N 10L6993) with P/N 37L0412.
Instructions for replacement are as follows:
Note: These drivers can be found at the following URL:
http://www.pc.ibm.com/searchfiles.html
search on "Fibre Drivers"
If they are not using the latest device driver, upgrade to the newest device driver.
Pages 8 & 9 of the "Netfinity Fibre Channel PCI Adapter Software Installation Guide" describes the
procedure for Updating the currently installed Windows NT Driver.
Note: The "Netfinity Fibre Channel PCI Adapter Software Installation Guide" is available in .pdf format from the following URL:
ftp://ftp.pc.ibm.com/pub/pccbbs/pc_servers/24l8026.pdf
Note: If in a cluster environment be sure to take down all servers one at a time.
Note: Be sure to turn off the 3526 using the two (2) power switches on the back of the 3526.
Note: If there is a second (failsafe) controller installed, and it also meets the ECA identification standards set forth in the Physical Check section of this ECA (i.e. lack of FRU label visible when fully seated) then both controllers must be replaced at the same service call.
Important: You must wait at least 2 minutes before powering on the servers.
It takes 2 minutes for the controller to come up.
Note: If it is not grayed out, and was before, then click on the Active/Active button
on the bottom left of the screen.
Otherwise it is in an Active Passive mode, and ensure the same controller that was Identified as Active in Step 1d is also identified as active now.
If it is not then press the Switch Active/Passive button in the lower middle of the window.
This is done by running the Manual Parity Check/Repair option in the Recovery Application outlined in the IBM Netfinity
SYMplicity Storage Manager User's Handbook.
The highlights of this are given below for convenience.
Running Manual Parity Check
TRADEMARKS:
Other company, product and service names may be the trademarks or service marks of others.
NOTES:
This ECA is "MANDATORY".
This ECA is scheduled to be withdrawn January 31, 2000.
Parts in "Features" Section, under "B/M to be Installed" column, MAY BE Ordered CODE "A".
The only part number which can be ordered for this ECA is the B/M P/N 37L0412, which will contain the FRU P/N 37L6077.
USA:
IBM PSS/TSS CE's should record all time and parts to Service Code 33, ECA029, Other Office 990.
Travel Time = 0.8Hrs.
USA Business Partners: Warranty claims for ECA Reimbursement should be submitted via ECLAIM using
Type Service 0E. Refer to the Service Support Guide (SSG) for details.
EMEA:
IBM PSS CE's should record all time and parts to Service Code 33, ECA029, (M/T number) Other Office 990.
Travel Time = 0.8Hrs.
EMEA Business Partners: Refer to Warranty Claim System; Use Emergency Claim 5 (ECA) and enter into CPPS:
ECA Number 029
Machine Type as required (number).