Record number: H165853
Device: D/T8660
Model: M
Hit count: UHC00026
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O99/01/28
Date last altered: A99/03/24
Owning B.U.: USA
Abstract: FLOPPY DRIVE ERROR: IF BOTH SERVERAID & ADAPTEC INSTALLED
SYMPTOM:
During POST the error 602 invalid diskette boot record displays.
In configuration/setup (F1) the diskette drive is listed as NONE or NOT INSTALLED.
Cannot boot from floppy diskette.
PROBLEM ISOLATION AIDS:
a Netfinity 7000-M10 server, Type 8680, any Model.
a Netfinity 7000 server, Type 8651, any Model.
a Netfinity 5500-M10 server, Type 8661, any Model.
a Netfinity 5500 server, Type 8660, any Model.
a Netfinity 5000 server, Type 8659, any Model.
a Netfinity 3500 server, Type 8644, any Model.
a Netfinity 3000 server, Type 8476, any Model.
a PC Server 330, Type 8640, any Model.
a PC Server 325, Type 8639, any Model.
a PC Server 310, Type 8639, any Model.
FIX:
Apply IBM ServeRAID BIOS Firmware Update Diskette version 3.11 or higher.