Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

OS/2 VIDEO CORRUPTION in TEXT MODE USING VGA DRIVER



Subject: OS/2 VIDEO CORRUPTION in TEXT MODE USING VGA DRIVER
Updated Netfinity server RETAIN Tip: 

    Record number:       H165581
    Device:              D/T8659
    Model:               M
    Hit count:           UHC00005
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O98/12/18
    Date last altered:   A99/01/15
    Owning B.U.:         USA


Abstract: OS/2 VIDEO CORRUPTION in TEXT MODE USING VGA DRIVER


SYMPTOM:

Part of text screen illegible in OS/2 in full-screen text mode. (No problem in GUI mode.)

Customer has not installed S3 video driver, or has disabled the S3 driver with ALT-F1 or a boot diskette.


PROBLEM ISOLATION AIDS:


FIX:

Installing the S3 video driver will eliminate this problem in normal operation.
The driver is located on the "Netfinity 5000 / 5500 / Netfinity 5500 M10/ 7000M10 S3 Trio V2/GX device driver diskette for OS/2" 24L8036.EXE located on the IBM web site at the following URL:

http://www.pc.ibm.com/searchfiles.html

If the standard OS/2 VGA driver is still desired over the S3 video driver, eliminate the problem
by either of the following two methods:



If video corruption occurs when using the ALT-F1 command prompt option, one of
the above methods must be used to update the CONFIG.X file in the \OS2\BOOT directory
(as in the config.sys installation).
Please refer to the README2.TXT on the S3 driver diskette for information about using "VIDFIX.EXE".