Abstract: OS/2 VIDEO CORRUPTION in TEXT MODE USING VGA DRIVER
SYMPTOM:
Part of text screen illegible in OS/2 in full-screen text mode. (No problem in GUI mode.)
Customer has not installed S3 video driver, or has disabled the S3 driver with ALT-F1
or a boot diskette.
PROBLEM ISOLATION AIDS:
FIX:
Installing the S3 video driver will eliminate this problem in normal operation.
The driver is located on the "Netfinity 5000 / 5500 / Netfinity 5500 M10/ 7000M10 S3 Trio V2/GX device
driver diskette for OS/2" 24L8036.EXE located on the IBM web site at the following URL:
http://www.pc.ibm.com/searchfiles.html
If the standard OS/2 VGA driver is still desired over the S3 video driver, eliminate the problem
by either of the following two methods:
Copy the BVHSVGA.DLL from the S3 diskette mentioned above to the \OS2\DLL directory.
Edit OS/2's CONFIG.SYS and add the text ",BVHSVGA" to the "SET VIO_VGA" statement
(if not already present) as as in the line below:
"SET VIO_VGA = DEVICE(BVHVGA,BVHSVGA)"