Abstract: NETWARE/NT INSTALLATION FAILS with ADAPTEC AAA131 ADAPTER
SYMPTOM:
Installation of Novell NetWare 4.11 or Microsoft Windows NT 4.0 fails on
PC Server 325/330 when CD-ROM is attached to an Adaptec AAA131 RAID Adapter.
PC Server 325/330 experiences a "system halt" failure when Novell NetWare 4.11 or
Microsoft Windows NT 4.0 are loaded with the SCSI CD-ROM unit disconnected from the on-board
ServeRAID/Adaptec SCSI controller and connected to an attached Adaptec AAA-131 Raid SCSI controller.
PROBLEM ISOLATION AIDS:
a PC Server 325, Type 8639, Model: PTW, PB0, RB0, PT0, 1RY or 2RY.
a PC Server 330, Type 8640, Model: PT0, PB0, PM0, 11Y or 21Y.
Novell NetWare 4.11
Microsoft Windows NT 4.0
FIX:
Do not connect the SCSI CD-ROM to the Adaptec AAA-131 RAID SCSI controller.
Connect the SCSI CD-ROM to the on-board ServeRAID or on-board Adaptec controller as it shipped from the factory.