Record number: H165674
Device: D/T8644
Model: M
Hit count: UHC00039
Success count: USC0000
Publication code: PC50
Tip key: 006
Date created: O99/01/08
Date last altered: A99/07/27
Owning B.U.: USA
Abstract: UNABLE TO START FIBRE ADAPTER CONFIGURATION PROGRAM
TEXT:
Unable to start Fibre Adapter configuration program
SYMPTOMS:
Error indicating that the Controller is not found when when Symbios Configuration program starts.
PROBLEM ISOLATION AIDS:
Fibre Channel, Option P/N 01K7296, FRU P/N 37L6077.
WORKAROUND:
Requirements:
Note: If Windows NT is installed then probably Hyperterm is available.
(See Below if you have trouble issuing the break key)
Procedure:
Only with the support from IBM levels 2, 3, or LSI should you even enter the Fibre controller
via the serial console because some commands that can be issued from there can cause data loss.
-CAUTION- This procedure will cause the loss of all LUNs and
Drive Configurations. Backup all data before proceeding.
This procedure is not to be used at any customers location that has data on any of the LUNs defined by
the controller to be sysWipe'd.
Normal problem determination does not require that this procedure be done. This is only to be done under the
advice of level 3 support or LSI support.
Note: If the FibrePort controller has 2 channels then they must both be cleared.
Note: All the keyboard input on this system is case sensitive so be sure to type in the Keyboard inputs exactly as shown.
You should get prompted for a password. (Password is "infiniti")
When the procedure completes...
Disconnect serial cable.
DETAILS:
This problem occurs when the adapter or the drives attached to the adapter have a configuration
that does not match the expected configuration.
The following is from the FAQ section from Hilgraeve (manufacturer of Hyperterm):
Q: How do I send a <Break> key?
A: Type <Ctrl><Break>. This didn't work in earlier releases running under NT 4.0.
It has been fixed in V3.0 and V4.0. Both versions also includes the ability to issue an
Interrupt Process command which is sometimes necessary when using Telnet.
That command is issued by <Alt><Break>
Note: Visit - http://www.hilgraeve.com , to download the latest version.
TRADEMARKS:
Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the
United States and/or other countries.
Other company, product and service names may be the trademarks or service marks of others.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.