Record number: H001448
Device: D/T8680
Model: M
Hit count: UHC00004
Success count: USC0000
Publication code: PC50
Tip key: 010
Date created: O99/01/04
Date last altered: A99/01/05
Owning B.U.: USA
Abstract: FALSE ERROR MESSAGE when RESTARTING SERVICE PROCESSOR
TEXT:
False error message when restarting service processor.
SYMPTOMS:
When a user presses the Restart button under the Network
Settings window in the Configuration Settings window in the
Advanced System Management service in Netfinity Manager to
restart the service processor, sometimes an error message box
will pop-up that says there was a command time-out. It occurs
much more frequently in OS/2 than Windows NT.
PROBLEM ISOLATION AIDS:
any supported version of OS/2
any supported version of Windows NT
WORKAROUND:
Go into the Network Driver Configuration program which comes
with Netfinity Manager and change the Network Time-Out from 15 to 30 seconds.
DETAILS:
Rarely occurs under Windows NT, changing time-out value gives
service processor more time to respond, the restarting actually succeeds so it is a false error message.
TRADEMARKS:
Microsoft, Windows, Windows NT, and the Windows logo are trademarks of Microsoft Corporation in the United States and/or
other countries.
Please see the LEGAL - Trademark notice.
Feel free - send a for any BUG on this page found - Thank you.