Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

ON/OFF SWITCH NOT WORKING after SYSTEM CATASTROPHIC FAILURE



Subject: ON/OFF SWITCH NOT WORKING after SYSTEM CATASTROPHIC FAILURE
New Netfinity server RETAIN Tip: 

    Record number:       H165467
    Device:              D/T8680
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:             009
    Date created:        O98/11/02
    Date last altered:   A98/11/02
    Owning B.U.:         USA


Abstract: ON/OFF SWITCH NOT WORKING after SYSTEM CATASTROPHIC FAILURE


TEXT:

On/Off switch will not work after system catastrophic failure.


SYMPTOM:

System may not respond to the On/Off switch once it has been shut down due a catastrophic failure.
Over voltage errors may get logged in the system error log. These errors are a possible cause of catastrophic failures.


PROBLEM ISOLATION AIDS:


WORKAROUND:

If the system shuts down due to a catastrophic failure, un-plug the AC cord and wait about 10 seconds before connecting again.
Power the system once AC cord is connected. If system does not respond, remove AC cord and then replace the 5V regulator card at the rear of system.
Plug AC cord and re-start.


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.
Feel free - send a Email-NOTE  for any BUG on this page found - Thank you.