Record number: H165424
Device: D/T8660
Model: M
Hit count: UHC00000
Success count: USC0000
Publication code: PC50
Tip key:
Date created: O98/10/21
Date last altered: A98/10/21
Owning B.U.: USA
Abstract: NETFINITY 5500: RAID OPTIONAL SCSI CABLE for EXTERNAL DEVICE
SYMPTOM:
When installing external SCSI devices to the Netfinity 5500, no external SCSI
port is available to attach the external device to the server.
PROBLEM ISOLATION AIDS:
Netfinity 5500 server Type 8660, any Model.
Netfinity 5500 M10 server, Type 8661, any Model.
FIX:
When installing external devices, order Option 03K9313, IBM Netfinity SCSI Controller Cable,
to provide a 0.8mm external connector for external SCSI devices.
Also order the appropriate cable to connect from the external device to the 0.8mm external connector.
Please see the LEGAL - Trademark notice.