Return to MAIN-Index  Return to SUB-Index    IBM-AUSTRIA - PC-HW-Support    30 Aug 1999

ADAPTER IRQ CHANGES / ADAPTER NOT VISIBLE in CONFIGURATION



Subject: ADAPTER IRQ CHANGES / ADAPTER NOT VISIBLE in CONFIGURATION
New Netfinity server RETAIN Tip: 

    Record number:       H165144
    Device:              D/T8650
    Model:               M
    Hit count:           UHC00000
    Success count:       USC0000
    Publication code:    PC50
    Tip key:
    Date created:        O98/11/03
    Date last altered:   A98/11/03
    Owning B.U.:         USA


Abstract: ADAPTER IRQ CHANGES / ADAPTER NOT VISIBLE in CONFIGURATION


SYMPTOM:

  1.  Adapter is not visible in the configuration when using SCU 3.61 or prior versions.
  2.  Adapter Interrupt setting changes on reboot.


PROBLEM ISOLATION AIDS:


An example of a card which fails is Intel PRO/100 Intelligent Server adapter, product code PILA-8465B.


FIX:

Symptom #1 is fixed by SCU 3.80 and symptom #2 is fixed by BIOS 16.


TRADEMARKS:

ActionMedia, LANDesk, MMX, Pentium and ProShare are trademarks of Intel Corporation in the United States and/or other countries.

(For a complete list of Intel trademarks see www.intel.com/tradmarx.htm )


Back to  Jump to TOP-of-PAGE
More INFORMATION / HELP is available at the  IBM-HelpCenter

Please see the LEGAL  -  Trademark notice.